ANALYTICAL TECHNIQUES in DNA SEQUENCING
DK1883_C000.fm Page ii Saturday, January 16, 1904 12:58 AM
ANALYTICAL TECHN...
29 downloads
1125 Views
5MB Size
Report
This content was uploaded by our users and we assume good faith they have the permission to share this book. If you own the copyright to this book and it is wrongfully on our website, we offer a simple DMCA procedure to remove your content from our site. Start by pressing the button below!
Report copyright / DMCA form
ANALYTICAL TECHNIQUES in DNA SEQUENCING
DK1883_C000.fm Page ii Saturday, January 16, 1904 12:58 AM
ANALYTICAL TECHNIQUES in DNA SEQUENCING Edited by
Brian K. Nunnally
Boca Raton London New York Singapore
A CRC title, part of the Taylor & Francis imprint, a member of the Taylor & Francis Group, the academic division of T&F Informa plc.
DK1883_Discl.fm Page 1 Monday, May 16, 2005 2:11 PM
Published in 2005 by Taylor & Francis Group 6000 Broken Sound Parkway NW, Suite 300 Boca Raton, FL 33487-2742 © 2005 by Taylor & Francis Group, LLC No claim to original U.S. Government works Printed in the United States of America on acid-free paper 10 9 8 7 6 5 4 3 2 1 International Standard Book Number-10: 0-8247-5342-9 (Hardcover) International Standard Book Number-13: 978-0-8247-5342-9 (Hardcover) Library of Congress Card Number 2004066429 This book contains information obtained from authentic and highly regarded sources. Reprinted material is quoted with permission, and sources are indicated. A wide variety of references are listed. Reasonable efforts have been made to publish reliable data and information, but the author and the publisher cannot assume responsibility for the validity of all materials or for the consequences of their use. No part of this book may be reprinted, reproduced, transmitted, or utilized in any form by any electronic, mechanical, or other means, now known or hereafter invented, including photocopying, microfilming, and recording, or in any information storage or retrieval system, without written permission from the publishers. For permission to photocopy or use material electronically from this work, please access www.copyright.com (http://www.copyright.com/) or contact the Copyright Clearance Center, Inc. (CCC) 222 Rosewood Drive, Danvers, MA 01923, 978-750-8400. CCC is a not-for-profit organization that provides licenses and registration for a variety of users. For organizations that have been granted a photocopy license by the CCC, a separate system of payment has been arranged. Trademark Notice: Product or corporate names may be trademarks or registered trademarks, and are used only for identification and explanation without intent to infringe.
Library of Congress Cataloging-in-Publication Data Analytical techniques in DNA sequencing / edited by Brian K. Nunnally. p. cm. Includes bibliographical references and index. ISBN 0-8247-5342-9 (alk. paper) 1. Nucleotide sequence. I. Nunnally, Brian K. QP625.N89A53 2005 611'.01816--dc22
2004066429
Visit the Taylor & Francis Web site at http://www.taylorandfrancis.com Taylor & Francis Group is the Academic Division of T&F Informa plc.
Preface The modern era of DNA sequencing began in late 1977 with the introduction of the most common DNA sequencing method, the Sanger method. The Sanger method involves the use of radioactive dideoxynucleotides, a deoxynucleotide with the 3′ hydroxyl group from the deoxyribose sugar removed.1 The Sanger method relies on statistics to create fragments that are terminated at every position of the DNA. The presence of a band indicates the base position and identity. Fluorescence-based sequencing was introduced in 1986 by L.M. Smith, L.E. Hood, and coworkers.2 Four different fluorescent dyes were attached to the dideoxynucleotides allowing for spectral discrimination of the fragments. Fluorescence shows comparable performance and is an attractive alternative due to its relative safety, real-time capability, and ease of automation, as well as the ability to multiplex. In addition, the fluorescent dyes do not significantly affect the fidelity of the enzymes.3 The first multiplex fluorescence-based sequencing systems used a four-channel approach, similar to the radioactive-based sequencing.4 Smith, Hood, and coworkers2 used a set of four dyes with different emission maxima. The signal was selected using different interference filters based on the different dye emission maxima. The first system of dyes included the following: fluorescein isothiocyanate (λem = 516 nm), NBD-aminohexanoic acid (λem = 540 nm), tetramethylrhodamine isothiocyanate (λem = 582 nm), and Texas Red (λem = 612 nm). This system was later commercialized by Applied Biosystems (ABI) using a revised set of dyes: FAM (λem = 521 nm), JOE (λem = 555 nm), TAMRA (λem = 580 nm), and ROX (λem = 605 nm).5 This commercial system allowed analytical sequencing to become a popular and routine technique for many laboratories. Mobility corrections are needed for this dye system. Ju et al.6 developed a novel energy transfer system that addressed some of the failings of this system, which allowed for more efficient excitation with equal mobilities. The original DNA sequencing systems were based on the standard slab polyacrylamide gel electrophoresis equipment, which allowed numerous samples to be analyzed on the same gel. Not long after the introduction of the slab-gel sequencing systems, a capillary electrophoresis (CE)-based sequencing system was developed. The CE system permitted increased speed, ease of use, and increased accuracy, although the CE system had a much lower throughput than the slab-gel system until the development of multicapillary systems. These systems are now commercially available and use from 8 to 96 capillaries in large arrays. Other techniques such as MALDI MS have been tried with modest success, but have no significant application. The future of DNA sequencing may lie in the use of microfabricated sequencing systems. These chipbased techniques will allow DNA sequencing to expand into a variety of new environments. From the early days of radioisotope sequencing, a wide variety of new techniques have emerged to meet the needs of biotechnology. Techniques aimed at reducing the
amount of sample needed, improving the accuracy, and reducing the amount of time needed to generate a sequence have been employed. The focus of this book is discussion of the different analytical DNA sequencing techniques, as well as some of the exciting applications of DNA sequencing. Numerous applications are discussed in this book, including microbiological identification, forensic DNA sequencing, and ancient DNA sequencing.
REFERENCES 1. F Sanger, S Nicklen, AR Coulson. Proc Natl Acad Sci USA 74, 5463–5467, 1977. 2. LM Smith, JZ Sander, RJ Kaiser, P Hughes, C Dodd, CR Connell, C Heiner, SBH Kent, LE Hood. Nature 321, 674–679, 1986. 3. LM Smith, S Fung, MW Hunkapiller, TJ Hunkapiller, LE Hood. Nucleic Acids Res 13, 2399–2412, 1985. 4. H Swerdlow, JZ Zhang, DY Chen, HR Harke, R Grey, S Wu, NJ Dovichi, C Fuller. Anal Chem 63, 2385–2841, 1991. 5. C Connell, S Fung, C Heiner, J Bridgham, V Chakerian, E Heron, B Jones, S Menchen, W Mordan, M Raff, M Recknor, L Smith, J Springer, S Woo, M Hunkapiller. BioTechniques 5, 342–348, 1987. 6. J Ju, AN Glazer, RA Mathies. Nat Med 2, 246–249, 1996.
Editor Brian K. Nunnally, Sr., Ph.D., received his Ph.D. in chemistry and a certificate in molecular biophysics from Duke University, Durham, NC, in 1998. He is assistant director at Wyeth Laboratories in Sanford, NC, where he works in Vaccine Analytical Development. Dr. Nunnally’s research interests lie in bioanalytical chemistry, including research on protein and polysaccharide therapeutics and BSE/TSE issues (BSE, bovine spongiform encephalopathy; TSE, transmissible spongiform encephalopathy). Prior to joining Wyeth, he worked for Eli Lilly and Company as a research scientist in quality control. Dr. Nunnally has published numerous articles and lectured on a variety of analytical and pharmaceutical disciplines. His graduate work focused on the development of multiplex detection for bioanalytical separations using fluorescence lifetime. This included DNA sequencing fragment separations. In 2004, the book Dr. Nunnally coedited with Professor Ira Krull, titled Prions and Mad Cow Disease (Marcel Dekker, New York), was published. Dr. Nunnally currently serves as assistant editor for Analytical Letters (CRC Press, Boca Raton, FL). He served as the cochair of the CE in the Biotechnology and Pharmaceutical Industries Conference in 2003 and 2004. Dr. Nunnally is a member of the Analytical Chemistry Division of the American Chemical Society and of the Society for Applied Spectroscopy. He was graduated with two honors degrees from University of South Carolina, Columbia. Dr. Nunnally is an Eagle Scout and father of two children, Brian Jr. and Annabelle.
Contributors Robert G. Blazej Department of Chemistry and UCSF/UCB Joint Graduate Group in Bioengineering University of California Berkeley, California William Goodwin Department of Forensic Medicine and Science University of Glasgow Glasgow, Scotland Samuel A. Heath Computer Science Department Brown University Providence, Rhode Island Franz Hillenkamp Institute for Medical Physics and Biophysics University of Münster Münster, Germany Dorrie Main Clemson University Genomics Institute Clemson, South Carolina Richard A. Mathies Department of Chemistry University of California Berkeley, California Terry Melton Mitotyping Technologies, LLC State College, Pennsylvania
Brian K. Nunnally Wyeth Laboratories Sanford, North Carolina Brian M. Paegel Department of Chemistry University of California Berkeley, California Franco P. Preparata Computer Science Department Brown University Providence, Rhode Island Markus Sauer Applied Laserphysics and Laserspectroscopy University of Bielefeld Bielefeld, Germany Jeffrey P. Tomkins Clemson University Genomics Institute Clemson, South Carolina Eli Upfal Computer Science Department Brown University Providence, Rhode Island Dirk van den Boom Sequenom, Inc. San Diego, California Victor W. Weedn Carnegie Mellon University Mellon Institute Pittsburgh, Pennsylvania
Kenneth D. Weston Department of Chemistry and Biochemistry Florida State University Tallahassee, Florida
Edward S. Yeung Ames Laboratory-USDOE and Department of Chemistry Iowa State University Ames, Iowa
Todd C. Wood Bryan College Dayton, Tennessee
Yonghua Zhang Ames Laboratory-USDOE and Department of Chemistry Iowa State University Ames, Iowa
Contents Chapter 1
Introduction to DNA Sequencing: Sanger and Beyond ......................1
Brian K. Nunnally Chapter 2
Developments in the Detection of DNA Sequencing Fragments Using Fluorescence: Energy Transfer and Fluorescence Lifetimes ...............................................................13
Brian K. Nunnally Chapter 3
Microscale Sample Preparation for DNA Sequencing and Genotyping ..................................................................................29
Yonghua Zhang and Edward S. Yeung Chapter 4
Microfabricated DNA Sequencing Devices ......................................61
Brian M. Paegel, Robert G. Blazej, and Richard A. Mathies Chapter 5
Analysis of Nucleic Acids by Mass Spectrometry............................85
Dirk van den Boom and Franz Hillenkamp Chapter 6
Sequencing the Single DNA Molecule............................................107
Kenneth D. Weston and Markus Sauer Chapter 7
DNA Sequencing for Genome Analysis..........................................157
Jeffrey P. Tomkins, Todd C. Wood, and Dorrie Main Chapter 8
Sequence Reconstruction from Nucleic Acid Microarray Data ...............................................................................177
Franco P. Preparata, Eli Upfal, and Samuel A. Heath Chapter 9
Ancient DNA ...................................................................................195
William Goodwin Chapter 10 Forensic DNA Sequencing...............................................................217 Terry Melton and Victor W. Weedn Index......................................................................................................................233
1
Introduction to DNA Sequencing: Sanger and Beyond Brian K. Nunnally
CONTENTS Introduction................................................................................................................1 Reactions....................................................................................................................2 Maxam–Gilbert Method ................................................................................2 Sanger Method...............................................................................................3 Comparison of the Maxam–Gilbert Method with the Sanger Method...............................................................................................3 Other Sequencing Methods ...........................................................................5 DNA Polymerases......................................................................................................6 Separation ..................................................................................................................6 Slab-Gel Sequencing .....................................................................................6 CE Sequencing ..............................................................................................7 Detection ....................................................................................................................9 Radioactive.....................................................................................................9 Fluorescence ..................................................................................................9 Conclusion: Impact of Sequencing .........................................................................10 Acknowledgments....................................................................................................11 References................................................................................................................11
INTRODUCTION The analytical chemistry of DNA sequencing is fascinating; the technology is impressive. When the Human Genome Project was commissioned in 1990, the goal was to complete the project in 15 years for less than U.S. $3 billion. This was considered a difficult set of goals by the originators of the project. Not only was the project completed in 10 years, but it was also completed under budget, a rarity for any government endeavor. The lasting impact of the Human Genome Project will be not only the 3 billion DNA bases, but also the analytical technology that allowed the project to be completed faster than expected. From the early days of radioisotope sequencing, a wide variety of new techniques have emerged to meet the needs of biotechnology. 1
2
Analytical Techniques in DNA Sequencing
Techniques aimed at reducing the amount of sample needed, improving the accuracy, and reducing the amount of time needed to generate a sequence have been employed. DNA sequencing involves a reaction, a separation, and detection and data analysis. The sequencing reactions can involve base-specific reactions or enzymatic extensions utilizing DNA polymerases. Separation methodology is commonly polyacrylamide gel electrophoresis (PAGE) or capillary electrophoresis (CE). The most common detection methodologies include fluorescence, although radioactivity has been used previously. Each of these steps is discussed in more detail.
REACTIONS MAXAM–GILBERT METHOD The Maxam–Gilbert sequencing method was actually published prior to the Sanger method (both were published in 1977). The Maxam–Gilbert method uses basespecific chemical degradation reactions to determine the sequence of an end-labeled DNA fragment. It is applicable to both single- and double-stranded DNA and requires no DNA polymerases. Four samples of radioactively end-labeled fragments are basespecifically chemically cleaved and separated electrophoretically in four separate lanes based on the specific reactions employed. A representative gel electropherogram is shown in Figure 1.1. Lanes 3'
Base ID A
A>G
G>A
C
C+T
A A C T G T C C A G G T C A G A G T 5'
C
FIGURE 1.1 A diagram of the electropherogram resulting from the electrophoresis of the four Maxam–Gilbert sequencing reactions. Because cytosine is cleaved in two separate reactions, bands that appear in the cytosine (C) and cytosine/thymine (C + T) lanes indicate cytosine. The guanine (G > A) and adenine (A > G) lanes do not show any light bands due to the other base, although they can be present.1 The sequence of this DNA is 5′-CTGAGACTGGACCTGTCAAA-3′.
Introduction to DNA Sequencing: Sanger and Beyond
3
The chemistry of the Maxam–Gilbert reactions is summarized in their 1977 publication.1 Briefly, the adenines and guanines are methylated. The glycosidic bond is broken at neutral pH and then 1.0 M NaOH cleaves the sugar from the phosphate groups. The guanines are methylated fivefold faster than the adenines,2 so the result is a dark guanine band and a weak adenine band (G > A). To enhance the adenine cleavage, the glycosidic bond is broken using dilute acid (0.5 M HCl). The result of cleavage with base is a dark adenine band and a weak guanine band (A > G). Cytosines and thymines are cleaved with hydrazine. The DNA is cleaved further with piperidine to give both cytosine and thymine bands. The addition of 2 M NaCl instead of water preferentially cleaves cytosine. Thus, the piperidine cleavages result in only cytosine bands. A diagram of the resulting electropherogram is shown in Figure 1.1.
SANGER METHOD The modern era of DNA sequencing began in late 1977 with the introduction of the most popular DNA sequencing method, referred to as the Sanger method,3 in honor of Fred Sanger, who was awarded a Nobel prize in 1980 for this work. This method starts with the denature of many copies of double-stranded DNA into single strands. The single-stranded DNA is mixed with a DNA polymerase, a DNA primer (a short single strand of DNA that will bind to the template DNA), deoxyribonucleotide triphosphates of all four bases (dNTPs, where N is the base), and a buffer (to minimize pH excursions). This mixture is aliquoted into four reaction tubes and a small amount of one of four dideoxynucleotide triphosphates (ddNTPs, where N is the base; the 3′ hydroxyl group from the deoxyribose sugar is removed); one ddNTP type (Figure 1.2) to each tube. The Sanger method involves the use of radioactive ddNTPs. These labeled dideoxynucleotides are added in addition to deoxynucleotides in a 1:100 ratio of each of the four reaction tubes. When each of the ddNTPs is incorporated into a sequence fragment, the fragment cannot be extended further. The Sanger method relies on statistics to create fragments that are terminated at every position of the DNA. The sequence is determined by comparing bands in each lane; only each band in one of the lanes of a DNA sequencing (i.e., PAGE) gel should appear at each position. The DNA sequencing gel is exposed to x-ray film, which is developed and the sequence is read from the bottom of the gel (5′ end) to the top of the gel (3′ end). The presence of a band indicates the base position and identity (Figure 1.3). Even in the first publication of this method, 300 bases from the primer site were determined.3
COMPARISON OF THE MAXAM–GILBERT METHOD WITH THE SANGER METHOD The Sanger method is widely used for large-scale sequencing projects. On the other hand, the Maxam–Gilbert method has not been utilized on a large scale for several reasons: base-specific fragments must be labeled and generated in two steps, labeling of DNA (and the whole technique, for that matter) is laborious and difficult, sequencing of ssDNA is thorny, and a primer walking strategy cannot be applied.4 Chemical
4
Analytical Techniques in DNA Sequencing
NH2 dATP O
O OH
NH2 dCTP
N
O
O
HO P O P O P O OH
N
O
N
N
O
N
O
HO P O P O P O
OH
OH
OH
O
OH
O
O
OH
OH
N
O
N
O dTTP NH
O
HO P O P O P O
N
NH2
OH
O
O OH
O
OH
OH
NH2 N
N
N
N
O
HO P O P O P O
OH
OH
OH
O
O
OH
OH
N
O
OH
NH
N
N
NH2
O
O
H3C
OH
NH
O
HO P O P O P O OH
H
O
O ddTTP
O
HO P O P O P O
N
OH H
ddGTP O
O
N
O
H
O
N
NH2
ddCTP O
O
O
OH OH
O
HO P O P O P O
NH
O
OH
O
H3C
HO P O P O P O OH
ddATP
O
OH O
dGTP
N
OH
O
N
O
OH H
FIGURE 1.2 The deoxyribonucleotides, including deoxyadenosine 5′-triphosphate (dATP), deoxyguanosine 5′-triphosphate (dCTP), deoxycytidine 5′-triphosphate (dCTP), and deoxythymidine 5′-triphosphate (dTTP), as well as the dideoxyribonucleotides, including dideoxyadenosine 5′-triphosphate (ddATP), dideoxyguanosine 5′-triphosphate (ddCTP), dideoxycytidine 5′-triphosphate (ddCTP), and dideoxythymidine 5′-triphosphate (ddTTP). The preparation of ddTTP26,27 was described previously in Sanger’s 1977 publication.3 The preparation of ddA was described previously28 and was combined with other established methods to prepare ddATP.29,30 The preparations of ddGTP and ddCTP were first described in the original Sanger method publication3 based on the same techniques used to prepare ddATP.
degradation methodologies have proved to be useful for eukaryotic genomes, especially those with rich GC contents, and provide more uniform band intensities.4 The Sanger method, because of its simplicity, has proved to be the “technique of choice” for DNA sequencing projects.
Introduction to DNA Sequencing: Sanger and Beyond
Base ID 3' A A A C T G T C C A G G T C A G A G T 5' C
ddATP
Lanes ddCTP ddGTP
5
ddTTP
FIGURE 1.3 A diagram of the gel electropherogram resulting from the electrophoresis of the four Sanger sequencing reactions. The bases are determined by reading the sequence information vertically. The gel electropherogram is called a sequencing ladder for this reason. The sequence of this DNA is 5′-CTGAGACTGGACCTGTCAAA-3′.
OTHER SEQUENCING METHODS Other sequencing methods have been developed since the initial development of the Sanger and Maxam–Gilbert methods. None has achieved the same level of usage as the Sanger method. In 1985, a single chemical cleavage method was developed.5 Extensive treatment of DNA with aqueous piperidine at 90°C cleaves the DNA at each nucleotide. The relative intensity of the band determined the nucleotide. The order of reactivity is adenine > guanine > cytosine > thymine. In addition to the base cleavage differences, band spacing is used as an additional criterion for base determination. The relative difference in band separations are as follows, 1.3 guanine:1.2 thymine:1.1 adenine:1.0 cytosine. As noted in the article,5 there are several advantages of this method compared with the conventional Maxam–Gilbert method. First, the procedure is greatly simplified, i.e., a single sample and a simplified reaction procedure. Second, dimethyl sulfate and hydrazine, two very toxic substances, are eliminated. Third, the amount of DNA needed is reduced, which is less of an issue with the introduction of polymerase chain reaction (PCR) and cycle sequencing. Finally, band ordering problems seen because of curvature due to intra-gel differences are eliminated. The method does not attain the level of accuracy obtained by either the Maxam–Gilbert or the Sanger methods.
6
Analytical Techniques in DNA Sequencing
In 1988, a new sequencing method based on the detection of inorganic phosphate (PPi ) was published.6 A DNA polymerase catalyzes the reaction of a dNTP with a template/primer and releases PPi, which is measured by light generation in the final step. The method appeared to work for the poly(dA·dT) sequence in the paper. However, no subsequent publications have appeared in the literature.
DNA POLYMERASES Several excellent review articles on DNA polymerases are available.7,8 The first enzyme used for DNA sequencing was the Klenow fragment,3 a large fragment of Escherichia coli DNA polymerase I. The Klenow fragment had several problems including lack of thermal stability and variable band intensities. The isolation, purification, and characterization of the DNA polymerase from Thermus aquaticus, an extreme thermophile, revolutionized DNA sequencing.9,10 These hyperthermophiles have evolved enzymes that are perfectly designed for DNA sequencing and PCR reactions. Because the enzyme was stable at high temperatures (optimum temperature of 80°C),9 longer reads were possible. This discovery eventually initiated a quest to discover and characterize DNA polymerases from other thermophilic species. As of 2001, more than 50 DNA polymerases from thermophiles had been characterized,8 including bacterial species from ocean vents and hot springs. Additional DNA polymerases are still being discovered and characterized.11,12 Could these be the future ideal DNA polymerase for DNA sequencing? The ideal DNA polymerase should have a rapid rate of dNTP incorporation, lack exonuclease activities, and not discriminate toward nucleotide analogues.13 High fidelity is also important. The native enzymes of these bacteria were often non-ideal for the intended biotechnological use. Companies such as Amersham Biosciences, Stratagene, New England Biolabs, and Perkin-Elmer have used genetic engineering techniques to produce mutants of the enzyme that eliminated other deficiencies, such as reduced incorporation of ddNTPs, variable band intensities, and high error rates. The pace of research appears to have slowed, but work is still being done. Through random and site-directed mutagenesis, polymerases with higher fidelity and increased incorporation of labeled ddNTPs have been created. Azrezi and colleagues14 reported using these techniques to find mutants that show 250-fold incorporation improvement of labeled ddNTPs. Patel and coworkers15 used similar techniques to understand the source of fidelity in T. aquaticus DNA polymerase. Isoleucine at position 614, part of the hydrophobic pocket that binds the base, was found to be critical to the fidelity.15
SEPARATION SLAB-GEL SEQUENCING The original DNA sequencing systems utilized standard slab PAGE equipment for separation of the products of the sequencing reactions. The PAGE experiment is not a true “electrophoresis” experiment. Electrophoresis is based on the separation of
Introduction to DNA Sequencing: Sanger and Beyond
7
molecules with different charges, and DNA molecules have, essentially, the same charge and extremely similar charge-to-mass ratios in the sequencing reaction separation. The PAGE experiment is actually a size-based separation. The polyacrylamide creates a plethora of different sized “pores.” DNA molecules become entangled in the pores. The larger the DNA fragment, the more entangled it becomes and the slower it moves through the gel (i.e., it will stay toward the top of the gel). Conversely, smaller fragments will move more rapidly through the gel matrix and will be found toward the bottom of the gel. The gels are typically 6% acrylamide in 1 × TBE (tris-borateEDTA) buffer.16 One of the early advantages of slab-gel electrophoresis over CE-based separations was the large throughput of the slab gels. In fact, 64-well combs were typically used for the sequencing gels allowing for as many as 16 different samples to be sequenced on one gel. Combs with more wells were also used, increasing the throughput even further. The small size of the bands in the gels with larger combs made them difficult to read. These throughput advantages have been largely overcome by the newer large-scale CE sequencing systems, which are described later. An excellent review and application article on slab-gel sequencing was published in the Methods in Enzymology series.16 As detailed in the article, the most important parameters to control in slab-gel preparation are elimination of dust particles, careful handling to reduce mechanical stresses, and careful pouring to reduce bubble formation.
CE SEQUENCING Not long after the introduction of the slab-gel sequencing systems, a CE-based sequencing system was developed. The CE system allowed for increased speed, ease of use, and improved accuracy, although the CE system had a much lower throughout than the slab-gel system, until the development of multicapillary systems. There are many excellent reviews of the subject. An older review of CE-based DNA sequencing is still an excellent consideration of the subject.19 Dovichi co-wrote a later review as well.17 Another more recent review focuses on the theoretical principles of the technique.18 CE separations offer several advantages over slab-gel-based sequencing systems.19 First, capillary systems are able to use dynamic coatings, allowing for replacement of the sieving matrix between separations. Slab gels must be poured and polymerized between the glass plates. The gels are difficult to pour (especially without creating bubbles) and time-consuming to prepare. Second, the flexible capillaries are easily coupled to a microtiter plate. As discussed later, this includes 384well microtiter plates. Finally, multicapillary systems can be created that greatly increase the throughput of a sequencing system, which is discussed in more detail in the next paragraph. Multicapillary systems are now commercially available and use from 8 to 384 capillaries in large arrays. These systems are overcoming the advantages of the slab-gel-based sequencing systems and are rapidly replacing them as the primary systems for large-scale DNA sequencing. Many companies offer 96-capillary
8
Analytical Techniques in DNA Sequencing
systems; SpectruMedix (State College, PA) and Nyxor Biotech (London, U.K.) have developed 192-capillary systems; and Amersham Biosciences introduced the MegaBACETM 4000 in the fall of 2001. This system was the first commercially available 384-capillary system, which is currently the largest number of capillaries commercially available on a single instrument. The MegaBACE 4000 system utilizes linear polyacrylamide-filled, 75 µm (i.d.) × 40 cm capillaries allowing read lengths of up to 1000 bp in 3 h.20 This translates to a theoretical yield of more than 3 million base pairs of DNA sequenced per day! With current microtiter plates available in 1536-well format, one could envision a 1536-capillary system (more than 12 million bases sequenced per day per instrument). The problem with these extremely large sequencing systems, a problem that will ultimately limit the size of the instrumentation, is generating the samples to run on them. One 96array system being sold by CombiSep (Ames, IA) uses technology developed in Ed Yeung’s laboratory at Iowa State University. The MCE 2000TM utilizes ultraviolet (UV) detection and a separation voltage of 250 V/cm.21 All other multicapillary DNA sequencing systems utilize fluorescence detection; however, Zhong and Yeung published a recent paper describing the use of UV absorption for the detection of DNA sequencing fragments.22 The advantages of using UV detection are mostly related to expense, in that fluorescence detection systems are expensive, as are the reagents.23 In addition, the mobility of the fragments is shifted because of the addition of the dye to the sequencing fragment.22 UV measurements are not without their drawbacks: UV is less sensitive, with detection limits that are inferior to fluorescence-based systems; in addition, four separate capillaries must be employed because there is no discrimination between DNA terminated with different ddNTPs. Because many of the common sieving matrices cannot be used when employing UV detection, a new dynamic sieving mechanism based on surfactant self-assembly was utilized by Zhong and Yeung.22 An internal standard was used because of differences between migration times in the multiple capillaries. The read length in this paper was short (approximately 100 bp), but shows much promise for the future. A 96-capillary array system microfabricated from a microchannel plate was created by Paegel and coworkers at the University of California, Berkeley.24 This system, which significantly reduces the amount of reagents and sample volume needed for the sequencing reactions, was able to obtain a read length of 430 bp. Further, the rate of sequencing information generated was approximately five times greater than current commercial capillary array systems. 24 Consumables for sequencing reactions run approximately $6.93/reaction (this amount includes labeling reagents, linear polyacrylamide, CE buffer, capillary arrays, and disposable plasticware).23 Recently, efforts have been made to minimize the amount of sequencing reagents used in an attempt to reduce the overall cost per reaction.23 Azadan and coworkers23 were able to reduce the amount of dye terminator used to 1:4 with no apparent statistical difference in read length or accuracy. More importantly, they were able to reduce the overall volume of the sequencing reaction to 5 µl without any reduction in read length or accuracy (although some additional variability in read length is noted at the lower volume). This information is summarized in Table 1.1.
Introduction to DNA Sequencing: Sanger and Beyond
9
TABLE 1.1 Average Read Length (with standard deviation) and Base Calling Accuracy (with standard deviation) for Various Sequencing Reactions, Including Dilutions of the Dye Terminator Premix and Reduced-Scale Sequencing Reactions
Description
Dye Terminator Dilution
Reaction Volume (µl)
Average Read Length (bp)
Standard Deviation
Base Calling Accuracy (%)
Standard Deviation
1:1
20
761
26
98.3
0.6
1:2
20
676
45
98.4
0.2
1:4
20
645
63
98.2
0.3
1:1
10
732
27
98.1
0.8
1:1
5
741
41
98.7
0.4
SOP reaction (“control”) Diluted terminator Diluted terminator Scaled-down reaction Scaled-down reaction
Source: Adapted from Azadan et al.23
DETECTION RADIOACTIVE Originally, detection was accomplished by radioactive labels such as 32P or 35S. Radioactive labels were extremely effective for detection of DNA sequencing reaction products. The labeled reagents are no different in size or shape than the unlabeled reagents, so the DNA polymerases exhibit no preference or fidelity reductions. However, radioactive gels must be exposed to the x-ray film, taking upward of 24 to 36 h to develop to collect 500 bases of sequencing data.
FLUORESCENCE The invention of fluorescence-based techniques has eliminated radioactive labels from almost all DNA sequencing. This is due to the increased safety, significantly decreased upkeep and disposal costs, ability to multiplex, and real-time data acquisition. Radioactivity requires special licensing and active management, elements that are unnecessary for fluorescence dyes. The ability to multiplex is a crucial parameter. Instead of using four different lanes of a PAGE gel, a single well with four labels is utilized. Finally, real-time data acquisition is possible, eliminating the need for off-line data collection (i.e., x-ray film exposure and development). The first fluorescence data system was developed in Hood’s laboratory in the mid-1980s.25 The original dye system utilized four dyes — fluorescein isothiocyanate, NBD-aminohexanoic acid, tetramethylrhodamine isothiocyanate, and Texas
10
Analytical Techniques in DNA Sequencing
Red — each with a different emission maximum. NBD-aminohexanoic acid was later replaced by a dye with a higher quantum yield and increased signal. The use of fluorescent dyes for DNA sequencing fragment detection was first commercialized by Applied Biosystems utilizing the dye set of FAM, JOE, TAMRA, and ROX. This detection methodology was responsible for most of the sequence generated from the Human Genome Sequencing Project. Chapter 2 discusses recent advances in fluorescence detection of DNA sequencing fragments.
CONCLUSION: IMPACT OF SEQUENCING
3000
35000
2500
30000 25000
2000
20000 1500
15000
1000
10000
500
Total # of papers
# of papers
DNA sequencing is not finished revolutionizing science. As of the end of 2003, more than 32,000 publications with the term “DNA sequencing” had been published (Figure 1.4). The new frontier is the ability to sequence DNA rapidly for use in medical diagnosis. Many challenges remain, although the technology is sufficiently advanced today to allow for increased use of this powerful diagnostic tool. The human genome, while sequenced, has not been completely deciphered, in that the functions of only a few genes are known. As medical science and molecular biology increase their knowledge, the use of DNA sequencing in medical diagnosis will increase. The future should allow for every individual’s genome to be sequenced (although the ethical hurdles are not insignificant). Techniques aimed at reducing the amount of sample needed, improving the accuracy, reducing the amount of time needed to generate a sequence have been employed. The focus of this book is to discuss some of the different analytical DNA sequencing techniques as well as some of the exciting applications of DNA sequencing. Advances in DNA separations through advanced CE and microchip sequencing are presented. Chapters in the book highlight improvements to the
5000 0 1971 1974 1977 1980 1983 1986 1989 1992 1995 1998 2001
0
Year
FIGURE 1.4 A graph of the total number of DNA sequencing-related publications according to MEDLINE by year. Numbers were compiled using PubMed (http://7.ncbi.nlm.nih.gov/entrez) based on a search for “DNA sequencing” limited by year. The first paper was published in 1972. A total of 32,697 papers have been published (as of 12/31/03). The trend is shown on the secondary y-axis. Data were compiled and were accurate as of 03/27/04.
Introduction to DNA Sequencing: Sanger and Beyond
11
detection of DNA sequencing fragments, including other types of fluorescence detection, the use of mass spectrometry, and single molecule detection. Chapters on the uses of DNA sequencing for forensic, ancient DNA analysis, and genome sequencing are included.
ACKNOWLEDGMENTS I acknowledge Deedra Nunnally for her assistance with literature searching and thank my colleague Kun Yao for his review and comments on this chapter. Figures containing chemical structures were prepared using ACD/ChemSketch available from Advanced Chemistry Development, ACD/Labs. A freeware version can be downloaded from www.acdlabs.com/downloads. The author of this chapter has no financial ties to any of the companies mentioned in the chapter.
REFERENCES 1. AM Maxam, W Gilbert. A new method for sequencing DNA. Proc Natl Acad Sci USA 74:560–564, 1977. 2. PD Lawley, P Brookes. Further studies on the alkylation of nucleic acids and their constituent nucleic acids. Biochem J 89:127–138, 1963. 3. F Sanger, S Nicklen, AR Coulson. DNA sequencing with chain-terminating inhibitors. Proc Natl Acad Sci USA 74:5463–5467, 1977. 4. A Rosenthal, B Sproat, H Voss, J Stegemann, C Schwager, H Erfle, J Zimmerman, C Coutelle, W Ansorge. Automated sequencing of fluorescently labeled DNA by chemical degradation. DNA Sequence 1:63–71, 1990. 5. BJB Ambrose, RC Pless. Analysis of DNA sequences using a single cleavage procedure. Biochemistry 24:6194–6200, 1985. 6. ED Hyman. A new method of sequencing DNA. Anal Biochem 174:423–436, 1988. 7. SC Hamilton, JW Farchaus, MC Davis. DNA polymerases as engines for biotechnology. BioTechniques 31:370–383, 2001. 8. H Hogrefe, J Cline, AE Lovejoy, KB Nielson. DNA polymerases from hyperthermophiles. Method Enzymol 334:91–116, 2001. 9. A Chien, DB Edgar, JM Trela. Deoxyribonucleic acid polymerase from the extreme thermophile Thermus aquaticus. J Bacteriol 127:1550–1557, 1976. 10. MA Innis, KB Myambo, DH Gefland, MAD Brow. DNA sequencing with Thermus aquaticus DNA polymerase and direct sequencing of polymerase chain reactionamplified DNA. Proc Natl Acad Sci USA 85:9436–9440, 1988. 11. Y Ishino, S Ishino. DNA polymerases from Euryarchaeota. Method Enzymol 334:249–260, 2001. 12. I Bruck, A Yuzhakov, O Yurieva, D Jeruzalmi, M Skangalis, J Kuriyan, M O’Donnell. Analysis of a multicomponent thermostable DNA polymerase 1 replicase from an extreme thermophile. J Biol Chem 277:17334–17348, 2002. 13. S Tabor, CC Richardson. DNA sequence analysis with a modified bacteriophage T7 DNA polymerase. Proc Natl Acad Sci USA 84:4767– 4771, 1987. 14. B Arezi, CJ Hansen, HH Hogrefe. Efficient and high fidelity incorporation of dyeterminators by a novel Archaeal DNA polymerase mutant. J Mol Biol 322:719–729, 2002.
12
Analytical Techniques in DNA Sequencing 15. PH Patel, H Kawate, E Adman, M Ashbach, LA Loeb. A single highly mutable catalytic site amino acid is critical for DNA polymerase fidelity. J Biol Chem 276:5044–5051, 2001. 16. LM Smith, RL Brumley, Jr, EC Buxton, M Giddings, M Marchbanks, X Tong. Highspeed automated DNA sequencing in ultrathin slab gels. Method Enzymol 271:219–237, 1996. 17. NJ Dovichi, J Zhang. DNA sequencing by capillary array electrophoresis. Method Mol Biol 167:225–239, 2001. 18. C Heller. Principles of DNA separation with capillary electrophoresis. Electrophoresis 22:629–643, 2001. 19. NJ Dovichi. DNA sequencing by capillary electrophoresis. Electrophoresis 18:2393– 2399, 1997. 20. http://www.amershambiosciences.com/aptrix/upp01077.nsf/content/6795588956BDB745 C1256BEC003023A3?OpenDocument&querytitle=&hometitle=search. 21. http://www.combisep.com/specs.html. 22. W Zhong, ES Yeung. Multiplexed capillary electrophoresis for DNA sequencing with ultra violet absorption detection. J Chromatogr A 960:229–239, 2002. 23. RJ Azadan, JC Fogleman, PB Danielson. Capillary electrophoresis sequencing: maximum read length at minimal cost. BioTechniques 32:24–28, 2002. 24. BM Paegel, CA Emrich, GJ Wedemayer, JR Scherer, RA Mathies. High throughput DNA sequencing with a microfabricated 96-lane capillary array electrophoresis bioprocessor. Proc Natl Acad Sci USA 99:574–579, 2002. 25. LM Smith, JZ Sander, RJ Kaiser, P Hughes, C Dodd, CR Connell, C Heiner, SBH Kent, LE Hood. Fluorescence detection in automated DNA sequence analysis. Nature 321:674–679, 1986. 26. AF Russell, JG Moffatt. Synthesis of some nucleotides derived from 3′-deoxythymidine. Biochemistry 8:4889–4896, 1969. 27. K Geider. DNA synthesis in nucleotide-permeable Escherichia coli cells. The effects of nucleotide analogues on DNA synthesis. Eur J Biochem 27:554–563, 1972. 28. JR McCarthy, MJ Robins, LB Townsend, RK Robins. Purine nucleosides. XIV. Unsaturated furanosyl adenine nucleosides prepared via base-catalyzed elimination reactions of 2′-deoxyadenosine derivatives. J Am Chem Soc 88:1549–1553, 1966. 29. GM Tener. 2-Cyanoethyl phosphate and its use in the synthesis of phosphate esters. J Am Chem Soc 83:159–168, 1961. 30. DE Hoard, DG Ott. Conversion of mono- and oligodeoxyribonucelotides to 5′-triphosphates. J Am Chem Soc 87:1785–1788, 1965.
2
Developments in the Detection of DNA Sequencing Fragments Using Fluorescence: Energy Transfer and Fluorescence Lifetimes Brian K. Nunnally
CONTENTS Introduction..............................................................................................................13 Energy Transfer–Based Fluorescence Sequencing .................................................14 Energy Transfer Primers..............................................................................14 BigDyeTM Chemistry ...............................................................................................19 Discrimination Using Fluorescence Lifetime .........................................................20 Time Domain ...............................................................................................21 Phase Domain ..............................................................................................23 Conclusion ...............................................................................................................26 Acknowledgments....................................................................................................26 References................................................................................................................27
INTRODUCTION Fluorescence has nearly eliminated radioactive-based sequencing as a detection technique for DNA sequencing fragments. The advantages of fluorescence are staggering. Fluorescence is cheaper (both to purchase and to dispose of), provides realtime data, allows for multiplex analysis (i.e., data on all four bases in the same lane), and is safer. There are several disadvantages of fluorescence-based detection that are not characteristic of radioactivity: dyes with fluorescent properties must be synthesized, the synthesized dyes must be conjugated to the biomolecule (either primer or dideoxynucleotide), and expensive detection systems must be employed. 13
14
Analytical Techniques in DNA Sequencing
These disadvantages have been steadily overcome through research, but improvements to the established methodology will be limited by these disadvantages. Fluorescent dyes that are to be utilized for DNA sequence fragment detection must have several properties. First, the set of dyes must have spectral discrimination. In this chapter, dye sets with emission-based discrimination and fluorescence lifetime discrimination are discussed. Ideally, the dyes will have good quantum yields (0.8 or higher). Quantum yield can be thought of as the efficiency of converting excitation radiation into emission signal (the higher the efficiency, the higher the signal). Increased signal allows for lower detection limits, which allows for more sequencing data per run. Quantum yield limitations can be overcome, in some ways, by increasing the power of the excitation radiation. This is not a panacea, as photobleaching and other deleterious effects will result if the laser power is too high. Finally, the dye must have a high molar absorptivity. Light that is not absorbed cannot be converted to signal. Regardless of the spectral discrimination employed, quantum yields and molar absorptivity are critical parameters for fluorescence detection of DNA sequencing fragments.
ENERGY TRANSFER–BASED FLUORESCENCE SEQUENCING It is extremely difficult to create a dye set with a single optimal excitation maximum, four well-resolvable emission spectra, and similar sizes to prevent mobility shifts. The invention of energy transfer primers solved many of these issues. The principle of energy transfer has been known for a long time, but was only applied to DNA sequencing in the mid-1990s. A “donor” dye is excited by a laser. The emission of the donor dye is used to excite a second dye (the “acceptor”). The efficiency of the energy transfer depends on the overlap of the donor emission spectrum and the acceptor excitation spectrum and the molecular distance between the donor and the acceptor. Two distinct approaches to energy transfer–based fluorescence sequencing have been undertaken. The first approach is to synthesize primers with the donor and acceptor dye separated by several DNA base pairs or by sugars. The second approach is to attach the donor and acceptor dyes together separated by a linker. The resulting dye dimer could be attached to either a primer or a dideoxynucleotide. Both approaches are discussed in more detail.
ENERGY TRANSFER PRIMERS The first reported energy transfer (ET) primers utilized FAM as the donor dye and the FAM, JOE, TAMRA, and ROX dye set as the acceptors.1 FAM is ideally excited by the 488-nm line of the argon ion laser and the four dyes have wellresolved emission maxima (525, 555, 580, and 605 nm, respectively). The contribution of FAM to the overall fluorescence signal in each channel was small and could be eliminated as a potential source of inaccuracy using filters. Data for the optimum primer set are shown in Table 2.1. The ET primers showed improved sensitivity relative to the standard single dye primer set. Normally, the TAMRA and ROX primers require threefold more template and twofold more
Developments in the Detection of DNA Sequencing Fragments Using Fluores-
TABLE 2.1 Summary of Data for the Optimized Primer Set for the First Reported Fluorescence Energy Transfer DNA Sequencing Primers Donor FAM FAM FAM FAM
Distance (bp)
Acceptor
Emission Maximum (nm)
Improvement
Efficiency (%)
Sensitivity (%)
10 10 3 3
FAM JOE TAMRA ROX
525 555 580 605
1.8 2.5 5.3 6.2
NA 65 97 96
160 360 400 470
Note: The distance was the distance between the donor and acceptor in base pairs (bp). The improvement was determined relative to the single dye excited at 488 nm (for example, the FAM-10-JOE energy transfer primer has a 2.5 times higher fluorescence signal, normalized for DNA content, than a JOElabeled primer excited at 488 nm). The efficiency was determined by comparison to the residual emission of FAM in the ET primers with a FAM-labeled primer of the same sequence and length. The sensitivity improvement was determined by plotting the band intensity vs. the quantity of template and comparing the slopes of the ET primers vs. the corresponding single-label primers. Source: Adapted from data reported in Ju et al.1
primer to obtain comparable signals for the TAMRA and ROX lanes; however, the ET primers do not require the additional template or primer.1 Another aspect of the optimization was the minimization of the mobility shifts needed for the standard single dye primer set. The mobility shift for the ET primers was reduced compared to the single dye labeled primers. The TAMRA and ROX labeled primers migrated nearly one nucleotide slower (compared to the FAM and JOE labeled primers) while the ET primers FAM-TAMRA and FAM-ROX migrated only one quarter of a nucleotide slower (compared to the ET primers for FAMFAM and FAM-JOE)1 In all, 500 bases of DNA were sequenced with 99.8% accuracy using these primers. A set of 20 different primers was synthesized and characterized to determine the optimum primer set.2 These primers varied in the position of the acceptor dyes. The tested distances between donor and acceptor were 1, 2, 3, 4, and 10 bp. Increasing the distance between the donor and acceptor dyes to 10 bp was determined to be better than the variable length described previously.1 The fluorescence signal of the FAM-TAMRA and FAM-ROX primers with 10 bp differences were threefold higher than the FAM-TAMRA and FAM-ROX primers with 3 bp differences. The increased distance between the donor and acceptor did not adversely affect the mobility (approximately 0.2 bp between the four primers). One consequence of the increased distance between donor and acceptor is increased FAM emission. The emission maxima are sufficiently well resolved to prevent this from affecting the base calling accuracy.2 The 500 bases of DNA were sequenced with 99.4% accuracy using these primers with a blind read. The improved signal strength allows for reduced template amount (when needed) or longer read lengths, if desired. This same dye set was
16
Analytical Techniques in DNA Sequencing
H3 CH2 CHN
+
O
NHCH2CH3
H3C
CH3 COOH
6-carboxyrhodamine 6G
HOOC
H3 CH2 CHN
+
O
NHCH2CH3
H3C
CH3 COOH
5-carboxyrhodamine 6G
COOH
FIGURE 2.1 The structure of 5-carboxyrhodamine 6G and 6-carboxyrhodamine 6G.4 All dyes are shown with carboxylic acid groups. The 5- and 6-carboxylic acids are changed to other functionalities, usually NHS esters, for conjugation to DNA primers or dideoxynucleotides.
used to sequence 600 bases with 100% accuracy and 850 bases with 98% accuracy, with the potential for ever longer reads.3 The emission of JOE overlaps with the emission of FAM. The use of a new dye, 5- or 6-carboxyrhodamine-6G (Figure 2.1) with a narrower emission spectrum (and thus less overlap) represents an improvement.4 The emission maxima for both 5-carboxyrhodamine-6G (558 nm) and 6-carboxyrhodamine-6G (555 nm) were similar to the emission maximum for JOE (555 nm) with similar fluorescence intensities. The mobility of the new ET primers (donor dye = FAM, acceptor dye = 5- or 6-carboxyrhodamine-6G, and distance = 10 bp) were improved relative to a similar JOE primer (donor dye = FAM, acceptor dye = JOE, and distance = 10 bp). The FAM-5-carboxyrhodamine-6G and FAM-6carboxyrhodamine-6G showed a mobility shift of less than 0.1 bp relative to the FAM-ROX ET primer while FAM-JOE showed a 0.2 bp mobility shift. Hung and coworkers4 were able to sequence 620 bases with 99% accuracy without the need for a mobility correction. In the effort to decrease the amount of signal obtained from the donor dye, a high-molar-absorptivity, low-fluorescence-quantum-yield dye was used as the donor dye.5 A cyanine dye (CYA; see Figure 2.2 for structure) with a molar absorptivity at 488 nm of 142,000 M–1cm–1 was used as the donor dye for FAM, 6-carboxyrhodamine-6G (R6G), TAMRA, and ROX acceptor dyes. The four primers (CYA-FAM, CYA-R6G, CYA-TAMRA, and CYA-ROX) utilized the same donor-acceptor difference (10) as optimized previously.3 The fluorescence intensity of the CYA-FAM primer was 80% of the fluorescence intensity of the FAM-FAM primer; the other primers showed increased fluorescence intensity when compared
Developments in the Detection of DNA Sequencing Fragments Using Fluores-
HC3
O N+ CH3
O N
CH3 COOH
FIGURE 2.2 The structure of CYA (3-(ε-carboxypentyl)-3′-ethyl-5,5′-dimethyloxacarbocyanine).5 The dye is shown with a carboxylic acid group. The carboxylic acid group is changed to other functionalities, usually a NHS ester, for conjugation to DNA primers or dideoxynucleotides.
with their corresponding FAM donor primers (CYA-R6G was 10% higher while CYA-TAMRA and CYA-ROX were each 70% higher). The new ET primers showed reduced crosstalk, as well as reduced mobility shifting. The 500 bases of DNA were sequenced with 100% accuracy using the new ET primer set. A comprehensive study of 56 different ET primers, differing in the spacing of the donor and acceptor, the type of spacer, the primer sequence, and the donor and acceptor dyes identified an improved ET primer set.6 A series of FAM-ROX primers with donor–acceptor differences of 1, 2, 3, 4, 6, 8, 10, and 12 bp were synthesized. The FAM-ROX primer with an eight pair difference gave the highest intensity. Primers with 10, 6, and 12 were fairly similar to each other and much higher than the primers with 4, 3, 2, or 1 bp differences. These results were similar to those generated previously.2 A series of FAM-ROX primers utilizing six, seven, eight, nine, or ten sugars (1′,2′-dideoxyribose phosphate) as the spacers were synthesized. Utilizing sugars as the spacer for the ET primers allows any primer to be utilized rather than specially synthesized primers. The eight, seven, nine, and ten sugar spacer primers had similar fluorescence intensities (much higher than the six sugar spacer primer). Several common primers (SP6, T3, T7, M13 forward, and M13 reverse) were synthesized as ET primers. Curiously, the distance between the FAM (donor) and ROX (acceptor) was not consistent between the primers, preventing a full comparison. A new dye, 5- and 6-carboxyrhodamine110 (R110; see Figure 2.3 for dye structures), was tested as a replacement for FAM as the acceptor dye. A set of primers utilizing CYA (Figure 2.2) as the donor dye and FAM, R6G, TAMRA, ROX, and R110 with donor–acceptor differences of 2, 4, 6, 8, 10, 12, 14, and 16 bp. The ideal (i.e., distance that gave the highest fluorescence intensity) donor–acceptor distance for all primers was 10.6 The emission maximum for the CYA-R110 primer is 530 nm. The CYA-R110 primer had only 70% of the emission intensity of a CYA-FAM primer, but the fluorescence
18
Analytical Techniques in DNA Sequencing
H2N
NH+2
O
COOH
6-carboxyrhodamine 110
HOOC
H2N
NH+2
O
COOH
5-carboxyrhodamine 110
COOH
FIGURE 2.3 The structure of 5-carboxyrhodamine-110 and 6-carboxyrhodamine-110. All dyes are shown with carboxylic acid groups. The 5- and 6-carboxylic acids are changed to other functionalities, usually NHS esters, for conjugation to DNA primers or dideoxynucleotides. (Adapted from http://www.probes.com/servlets/structure?item=6479.)
intensity was still stronger (approximately 30%) than CYA-ROX, rendering it suitable for use in DNA sequencing.6 The primer set of CYA-R110, CYA-R6G, CYA-TAMRA, and CYA-ROX (an entire rhodamine acceptor dye set) was utilized to sequence 600 bases with 100% accuracy and 850 bases with 98% accuracy. The mobility was also improved and well matched with the other primers. BODIPY dyes have been used as donor–acceptor dyes for ET primers.8 The narrow excitation and emission spectra combined with the high molar absorptivities of BODIPY dyes make them excellent dyes for use in DNA sequencing. BODIPY 503/512 (Figure 2.4) was utilized as the donor for all of the ET primers. The acceptor dyes were BODIPY 523/547, BODIPY 564/570, and BODIPY 581/591 (Figure 2.4). Amino linker arms (either a propyl or hexyl group) were used to separate the donor and acceptor dye linker arm. The length of the linker arms was fairly innocuous as less than a 5% fluorescence intensity difference between primers with the two different linker arms was noted. The overall intensity of the BODIPY-labeled primer was much lower than the fluorescence intensity of other ET primers. The FAM-ROX ET primer gave 2.7-fold more signal when compared to the BODIPY 503/512BODIPY 581/591 primer when excited at 488 nm (both primers utilized a 3 bp separation). With excitation at 514 nm, the two ET primers gave similar fluorescence signals. A number of FAM-ROX primers could be created (by increasing the base pair separation) that exhibited severalfold fluorescence signal improvements vs. the optimal BODIPY 503/512-BODIPY 581/591 primer (BODIPY 503/512-BODIPY 581/591 with a 3 bp distance between donor and acceptor, a propyl amino linker, and excitation at 514 nm).
Developments in the Detection of DNA Sequencing Fragments Using Fluores-
H3C
BODIPY 503/512 N
H3C
B F F
BODIPY 523/547 N
N+
N+
B
F F COOH COOH
BODIPY 564/570
N
B
N+
BODIPY 581/591 N
B
N+
F F
F F COOH
COOH
FIGURE 2.4 The structure of BODIPY dyes used for energy transfer primers.8 All dyes are shown with carboxylic acid groups. These carboxylic acid groups are changed to other functionalities, usually NHS esters, for conjugation to DNA primers or dideoxynucleotides. (Adapted from Metzker et al.15)
BigDye™ CHEMISTRY In the 1980s, Molecular Probes synthesized an energy transfer dye by linking 5carboxytetramethylrhodamine and 5-carboxyfluorescein.9 The resulting dye had an absorption spectrum that was the combination of the two individual spectra, but an emission spectrum of only 5-tetramethyrhodamine. The approach of using energy transfer dyes consisting of a donor and acceptor dye tethered together, rather than separated by several nucleotides has proved effective. The first set of dyes, trademarked as BigDyes, utilized fluorescein and dichlorinated rhodamine dyes (Figure 2.5).9 Dichlorinated rhodamine dyes have narrower emission profiles and slightly longer wavelength for their emission maxima relative to the same nonchlorinated rhodamine dyes.9 The ET dyes synthesized here were only ~60% of maximal brightness, with both lower extinction coefficients and quantum yields than the rhodamine dyes alone. Despite these results, the ET dyes are brighter than the rhodamine dyes alone. The BigDyes were conjugated to a –21 M13 primer and utilized in a DNA sequencing run resulting in 700 bases of sequencing data before the first unambiguous call. The combination of dyes shown in Figure 2.5 required a mobility correction no larger than 0.4 bp. The BigDyes dye set (Figure 2.5) was conjugated to dideoxynucelotides for use in DNA sequencing.10 The average errors (to 720 bp), average read length at 98.0% accuracy, and signal strength for the BigDye dye terminators and two non-energy transfer dye sets are shown in Table 2.2. The average errors for the BigDye dye
20
Analytical Techniques in DNA Sequencing
H3C
N(CH3 )2
Cl
Cl O
O
O
O NH
NH
Cl HOOC
Cl HOOC
H3C
N(CH3 )2
NH
O
NHCH2 CH3 +
O
+
O NH
NHCH2 CH3
O
Fluorescein-dR6G
Fluorescein-dTMR O
O COOH
HO
HO
COOH
HOOC
COOH
N
NH2 Cl
Cl
O
O
O
O
NH
NH
Cl HOOC
Cl HOOC
N+
NH2 +
O
O
NH
NH
O
O
Fluorescein-dROX
Fluorescein-dR110 O
O HO
HO
COOH
COOH
COOH
COOH
FIGURE 2.5 Structure of the optimal BigDye dye set. (Adapted from Lee et al.9)
terminators and the dicholorhodamine dye terminators are significantly lower (at the 95% confidence level) than the average errors for the rhodamine dye terminators. The average read length for the BigDye dye terminators and the dicholorhodamine dye terminators is significantly higher (at the 95% confidence level) than the average errors for the rhodamine dye terminators. For both the average errors and average read length, there is no statistical difference between the dicholorhodamine dye terminators and the BigDye dye terminators. The BigDye dye terminators give significantly more signal strength than either the dicholorhodamine dye terminators or the rhodamine dye terminators.
DISCRIMINATION USING FLUORESCENCE LIFETIME The dyes used for the detection of DNA sequencing fragments by fluorescence lifetime require some different characteristics than emission dyes. Similar to emission-based detection systems, fluorescence lifetime dyes require good quantum yields and high molar absorptivity. The spectral discrimination employed is
Developments in the Detection of DNA Sequencing Fragments Using Fluores-
TABLE 2.2 Statistics for the BigDye Dye Terminatorsa Compared to Non-Energy Transfer Dye Sets
Rhodamine dye set Dichlororhodamine dye set BigDyeTM dye set
Average Errors to 720 Bases
Error Standard Deviation
Average Read Length at 98.0% Accuracy
Read Length Standard Deviation
Signal Strength
Signal Strength Standard Deviation
20.39 9.17
14.99 5.02
662.9 748.4
133.7 43.6
2117.1 858.3
1005.6 413.4
8.61
9.02
759.2
64.6
3081.7
1448.7
a
See Figure 2.5 for the dye structures. Note: The rhodamine dye set includes Rhodamine 6G, ROX, Tetramethylrhodamine, and Rhodamine 110. The dichlororhodamine dyes are the same dyes with chlorines substituted for hydrogens at the 4 and 7 positions. Source: Adapted from data reported in Rosenblum et al.10
distinct fluorescence lifetimes. The emission maxima of the dyes can be exactly the same (in fact, it is helpful if they are). The theoretical fluorescence lifetime difference required is 20%.14 The fluorescence lifetime measurement is independent of signal and is constant once the limit of detection has been overcome. The fluorescence lifetime should, ideally, be monoexponential. Multiexponential decay will make overlapping peaks difficult to resolve, a critical success factor for long reads. A large emission window is able to be used. Finding dyes with these characteristics has been a challenge. There are two ways of measuring fluorescence lifetime, time domain and phase domain. An excellent review article on the use of fluorescence lifetime to detect DNA sequencing fragments has been published.11 The use of fluorescence lifetime, both time domain and phase domain, is discussed in more detail below.
TIME DOMAIN Time-domain measurements utilize a short (the shorter the better) excitation pulse to excite the dye molecules. The signal is measured as a function of time. The equation that governs this process is shown below.22 F(t) = N0 /γe−t/τ
(2.1)
where F(t) is the fluorescence intensity, N0 is the initial population of fluorophores, γ is the emissive rate, τ is the lifetime, and t is the time. The signal decays exponentially over time. The fluorescence lifetime is either determined from the slope of the plot of log F(t) vs. time or by determining the time required for the signal to decay to 1/e of the original signal.22
22
Analytical Techniques in DNA Sequencing
-O S 3
CH3
SO 3-
CH 3 CH 3 Cy5
N
H3 C H3 C
H3C
N
H3C
N+
CH 3
N+
O
N
JA242
CH3
COOH F
HOOC
COOH
Cl
F
F
F F
F
N+
N+
O
CH3
Cl
Cl
COOH CH3
N H3C
JA169 COOH
Cl
H3C COOH
N+
O CH3
MR200-1
N
CH3 CH3 COOH
FIGURE 2.6 The dye set utilized for the first example of utilizing fluorescence lifetime for the detection of DNA sequencing fragments. (Adapted from Lieberwirth et al.12)
The first demonstration of lifetime detection for DNA sequencing occurred in 1998.12 Three new dyes were synthesized and combined with a commercially available cyanine dye (Figure 2.6) to create a set of dyes with distinct fluorescence lifetimes. The dyes had varied absorbance maxima (from 624 to 6669 nm). A semiconductor laser emitting at 630 nm was used for excitation. The average laser power was only 0.6 mW. High laser powers are not needed in the red region of the electromagnetic spectrum because there is low background signal in this region. The dyes were conjugated to a sequencing primer (5′-TGT17ACGACGGCCAGT-3′). The conjugated Cy5 exhibited a lifetime of 1.6 ns, conjugated JA242 exhibited a lifetime of 2.4 ns, conjugated JA169 exhibited a fluorescence lifetime of 2.9 ns, and conjugated MR200-1 exhibited a fluorescence lifetime of 3.7 ns. Utilizing this dye set, 660 bp were sequenced with 90% accuracy. The accuracy was adversely affected by two dyes, JA242 and JA169, exhibiting multiexponential decay. The mobility shift was small, less than 0.2 bp for the Cy5-labeled fragments. This low amount of mobility shift was achieved by introducing linkers between the dye and oligonucleotide and selecting a coupling position that minimizes the mobility shift. Lassiter and coworkers13 utilized fluorescence lifetime detection for detecting DNA sequencing fragments separated by a slab gel. Two commercially available fluorescent dyes in a two-lane scheme were employed. The average lifetime of IRD700 was 718 ps while Cy5.5 exhibited an average lifetime of 983 ps. With this approach, 670 bases of sequencing data were generated with 99.7% accuracy. An overlapping peak with as little resolution as 0.36 was able to be correctly identified.
Developments in the Detection of DNA Sequencing Fragments Using Fluoresφ
Excitation Emission
Intensity
B B'
A A' Time
FIGURE 2.7 A theoretical excitation and emission signal used to determine the fluorescence lifetime at a single frequency is presented. The fluorescence lifetime is calculated utilizing Equations 2.2 and 2.3 based on the phase shift of the emission (relative to the excitation phase) and the demodulation (relative to the excitation amplitude). (Adapted from Nunnally.17)
PHASE DOMAIN The first fluorescence lifetime instruments utilized phase-domain.16 In phase-domain measurements, the excitation light is sinusoidally modulated. When the molecules fluoresce, the emission is phase shifted and demodulated relative to the excitation (Figure 2.7). The equations used to calculate the lifetime (Equations 2.2 and 2.3) are shown below.17 τp = ω–1 tan φ
(2.2)
τm = ω–1[(1/m2) – 1]1/2
(2.3)
where τp is the lifetime measured by the phase shift, ω is the angular modulation frequency applied to the excitation light, φ is the phase shift of the light, τm is the lifetime measured by the demodulation of the emission, m is the demodulation factor, calculated from the ratio of the change in amplitude for the excitation and emission signal, i.e., m = (B/A)/(B′/A′). Figure 2.7 provides a visual for the terms in these equations. For a dye with monoexponential decay, the two lifetimes are equal. Modern instrumentation is capable of measuring multiple frequencies simultaneously. Data analysis software is able to deconvolute the data and provide a more accurate lifetime measurement than was capable with only a single frequency. There has only been one reported use of phase domain measurements for the detection of DNA sequencing fragments.18 The use of phase-domain fluorescence lifetime detection for capillary electrophoresis had been demonstrated previously.19 After demonstrating that the technique was suitable for the detection of dye-labeled DNA primers,20,21 He and McGown18 sequenced nearly 200 bases of DNA with 96% accuracy using a dye system excited by a 488-nm argon ion laser. This detection scheme challenged the detection limit capability of the system and required some
24
Analytical Techniques in DNA Sequencing
H3C HO3S
CH3
H3C
N
CH3 CH3
Cy3
N H3C
N+ HOOC
B O DIPY FL
B F
N+ F COOH
H3C
N(CH3 )2
SO3H Cl O NH+2
O
H2N
O NH Cl HOOC
COOH N(CH3 )2 +
O
HOOC
NH
O
Rhodamine Green
Fluorescein-dTMR
O HO
COOH
COOH
FIGURE 2.8 The 488-nm dye set used by He and McGown.18 All dyes are shown with carboxylic acid groups. These carboxylic acid groups (the carboxylic acid group in the 6 position for Rhodamine Green and the 5 position of the fluorescein dye on the fluoresceindTMR) are changed to other functionalities, usually NHS esters, for conjugation to DNA primers or dideoxynucleotides. (Figure adapted from Nunnally;17 structure of fluoresceindTMR adapted from Lee et al.9)
optic modification to increase the signal collected from the capillary system. The 488-nm dye set used is shown in Figure 2.8. One of the dyes, fluorescein-dTMR, showed significant mobility shifts relative to the other dyes and required sequential injections to compensate for this issue. The lifetime of each of the 488-nm dyes was 1.7 ns (Cy3), 2.5 ns (fluorescein-dTMR), 2.9 ns (Rhodamine Green), and 3.9 ns (BODIPY-FL). The lifetimes of both Rhodamine Green and BODIPY-FL were much shorter than previously noted,17 which may indicate the dye is being quenched by the gel matrix. He and McGown18 attempted to use another dye set excited by the 514-nm line of an argon ion laser. This dye set is shown in Figure 2.9. The 514-nm dye set had good lifetime resolution, but one of the dyes (BODIPY–FL Br2) had a
Developments in the Detection of DNA Sequencing Fragments Using Fluores-
H3C HO3S
CH3
BODIPY FL Br2
H3C
N
Br
CH3 CH3
Cy3
N H3C
N+
B F
Br
N+ F
COOH
H3C
HOOC
SO3H
Tetramethylrhodamine (H3 C)2 N
+
O
BODIPY 530/550
N(CH3 )2
N+
N B
COOH F HOOC
F COOH
FIGURE 2.9 The 514-nm dye set used by He and McGown.18 All dyes are shown with carboxylic acid groups. These carboxylic acid groups are changed to other functionalities, usually NHS esters, for conjugation to DNA primers or dideoxynucleotides. (Adapted from Nunnally.17)
weaker signal and no replacement could be found. By using only the three dye combination (i.e., only three bases could be identified), the accuracy was improved to 98.5%. Li and McGown23 found that the composition of the gel, including degree of cross-linking, type of cross-linker, and organic modifiers could affect the fluorescence lifetime offering the possibility of tuning or optimizing the fluorescence lifetimes for better discrimination in sequencing. A new set of dyes, based on an acridone structure, was developed for use in phase-domain lifetime sequencing.24 The structure of the acridone dyes are shown in Figure 2.10. These dyes have a great deal of homology, thus minimizing mobility shifts. The key property of these dyes is the difference in their fluorescence lifetimes. The four dyes have broad absorption spectra centered around 405 nm24 and can be excited by a violet laser diode. The four dyes have distinctly different fluorescent lifetimes. The lifetimes of the dye-labeled primers detected on capillary were 4 ns (Dye I), 6 ns (Dye II), 11 ns (Dye 22), and 14 ns (Dye IV). These dyes are well suited to DNA sequencing utilizing fluorescence lifetime detection because of the magnitude of their lifetimes, lifetime differences between the dyes, and similar absorption maxima. No sequencing data have been reported using this dye system, but the early results are promising.
26
Analytical Techniques in DNA Sequencing
Dye I
O
O
Br
N N H O
Dye II
NH
COOH
O COOH O NH
CH3
N O N
Dye III
Dye IV
COOH COOH
FIGURE 2.10 The structures of the acridone dye set investigated by Mihindukulasuriya et al.24 All dyes are shown with carboxylic acid groups. These are changed to other functionalities, usually NHS esters, for conjugation to DNA primers or dideoxynucleotides.
CONCLUSION Alternatives to the standard four-color detection scheme for DNA sequencing are varied. Two fluorescence approaches, energy transfer dye sets and fluorescence lifetime, maintain some of the intrinsic advantages of fluorescence while addressing some of the weaknesses of the standard fluorescence detection schemes. Energy transfer dye sets are widely in use, whereas fluorescence lifetime based sequencing has yet to reach its potential. Time will be the final judge of the utility of the fluorescence lifetime approach.
ACKNOWLEDGMENTS I thank my colleague Kun Yao for his review and comments on this chapter. Figures containing chemical structures were prepared using ACD/ChemSketch available from Advanced Chemistry Development, ACD/Labs. A freeware version can be
Developments in the Detection of DNA Sequencing Fragments Using Fluores-
downloaded from www.acdlabs.com/downloads. The author of this chapter has no financial ties to any of the companies mentioned in the chapter.
REFERENCES 1. J Ju, C Ruan, CW Fuller, AN Glazer, RA Mathies. Fluorescence energy transfer dyelabeled primers for DNA sequencing and analysis. Proc Natl Acad Sci USA 92:4347–4351, 1995. 2. J Ju, I Kheterpal, JR Scherer, C Ruan, CW Fuller, AN Glazer, RA Mathies. Design and synthesis of fluorescence energy transfer dye labeled primers and their application for DNA sequencing and analysis. Anal Biochem 231:131–140, 1995. 3. J Ju, AN Glazer, RA Mathies. Energy transfer primers: a new fluorescence labeling paradigm for DNA sequencing and analysis. Nat Med 2:246–249, 1996. 4. SC Hung, J Ju, RA Mathies, AN Glazer. Energy transfer primers with 5- or 6carboxyrhodamine 6G as acceptor chromophores. Anal Biochem 238:165–170, 1996. 5. SC Hung, J Ju, RA Mathies, AN Glazer. Cyanine dyes with high absorption cross section as donor chromophores in energy transfer primers. Anal Biochem 243:15–27, 1996. 6. SC Hung, RA Mathies, AN Glazer. Optimization of spectroscopic and electrophoretic properties of energy transfer primers. Anal Biochem 252:78–88, 1997. 7. http://www.probes.com/servlets/structure?item=6479. 8. SC Hung, RA Mathies, AN Glazer. Comparison of fluorescence energy transfer primers with different donor-acceptor dye combinations. Anal Biochem 255:32–38, 1998. 9. LG Lee, SL Spurgeon, CR Heiner, SC Benson, BB Rosenblum, SM Menchen, RJ Graham, A Constantinescu, KG Upadhya, JM Cassel. New energy transfer dyes for DNA sequencing. Nucleic Acids Res 25:2816–2822, 1997. 10. BB Rosenblum, LG Lee, SL Spurgeon, SH Khan, SM Menchen, CR Heiner, SM Chen. New dye-labeled terminators for improved DNA sequencing patterns. Nucleic Acids Res 25:4500–4504, 1997. 11. SJ Lassiter, WJ Stryjewski, Y Wang, SA Soper. Shedding light on DNA analysis. Spectroscopy 17:14–23, 2002. 12. U. Lieberwirth, J Arden-Jacob, KH Drexhage, DP Herten, R Müller, M Neumann, A Schulz, S Siebert, G Sagner, S Klingel, M Sauer, J Wolfrum. Anal Chem 70:4771–4779, 1998. 13. SJ Lassiter, WJ Stryjewski, BL Legendre, Jr., R Erdmann, M Wahl, J Wurm, R Peterson, L Midendorf, SA Soper. Time-resolved fluorescence imaging of slab gels for lifetime base-calling in DNA sequencing. Anal Chem 72:5373–5382, 2000. 14. MB Smalley, LB McGown. Limits of detection and resolution for on-the-fly fluorescence lifetime detection in HPLC. Anal Chem 67:1371–1376, 1995. 15. ML Metzker, J Lu, RA Gibbs. Electrophoretically uniform fluorescent dyes for automated DNA sequencing. Science 271:1420–1422, 1996. 16. Z Gaviola. Ein Fluorometer. Apparat zur Messung von Fluoreszenzabklingungszeiten. Z Phys 42:853–861, 1926. 17. BK Nunnally. Multiplex detection in capillary electrophoresis using fluorescence lifetime. PhD dissertation, Duke University, Durham, NC, 1998. 18. H He, LB McGown. DNA sequencing by capillary electrophoresis with four-decay fluorescence detection. Anal Chem 72:5865–5873, 2000.
28
Analytical Techniques in DNA Sequencing 19. LC Li, LB McGown. On-the-fly frequency-domain fluorescence lifetime detection in capillary electrophoresis. Anal Chem 68:2737–2743, 1996. 20. H He, BK Nunnally, LC Li, LB McGown. On-the-fly fluorescence lifetime detection of dye-labeled DNA primers for multiplex analysis. Anal Chem 70:3413–3418, 1998. 21. LC Li, H He, BK Nunnally, LB McGown. On-the-fly fluorescence lifetime detection of labeled DNA primers. J Chromatogr B 695:85–92, 1997. 22. JR Lackowicz. Principles of Fluorescence Spectroscopy. New York: Plenum Press, 1983, 52–53. 23. L Li, LB McGown. Effects of gel material on fluorescence lifetime detection of yes and dye-labeled DNA primers in capillary electrophoresis. J Chromatogr A 841:95–103, 1999. 24. SH Mihindukulasuriya, TK Morcone, LB McGown. Characterization of acridone dyes for use in four-decay detection in DNA sequencing. Electrophoresis 24:20–25, 2003.
3
Microscale Sample Preparation for DNA Sequencing and Genotyping Yonghua Zhang and Edward S. Yeung
CONTENTS Introduction..............................................................................................................29 Challenges in Genomic Analysis ............................................................................31 Plasmid Preparation for DNA Sequencing .................................................31 DNA Ladder Purification and Sample Injection.........................................31 Preparation of Biological Samples for PCR ...............................................33 Total System Integration..............................................................................33 Capillary Microfluidics Systems........................................................34 Online Microchip Systems.................................................................34 Capillary Array Instruments ........................................................................35 Emerging Technologies ...........................................................................................37 Sequencing Directly from Single Bacterial Colonies.................................37 Sequencing Based on Nanoliter Reaction Volumes....................................41 Sample Manipulation .........................................................................41 Online Sample Purification................................................................47 High-Throughput PCR Analysis of Clinical Samples ................................52 Acknowledgment .....................................................................................................56 References................................................................................................................56
INTRODUCTION The greatest achievement in molecular biology in the past decade is undoubtedly the sequencing of the human genome. The announcement of the completion of the Human Genome Project in June 2000 marks the availability of the rough draft about 3 years ahead of schedule. The remaining sequencing tasks should be completed in 2003. There is general agreement that one of the major developments that allowed such rapid progress is the availability of high-throughput DNA 29
30
Analytical Techniques in DNA Sequencing
sequencers based on capillary electrophoresis (CE). These automated instruments eliminated most of the manual operations associated with the older generation of DNA sequencers, thereby substantially increasing the throughput. The completion of the Human Genome Project does not mean the end of technology development relevant to DNA sequencing. There are many more genomes to be sequenced. With each sequenced genome, there are many more individuals to be compared with the “standard” sequence. In this chapter, we review three different types of DNA technologies that may be the key to future applications of genomics. Life sciences took center stage virtually around the world on June 26, 2000, when President Clinton announced the completion of the working draft of the entire human genome.1 The working draft consisted of sequences of 85 to 90% of the 3 billion DNA bases. It is essentially the “blueprint” for the construction of humans, which holds great potential in the discovery of functional genes, the elucidation of disease-causing mutations within the genes, and the development of diagnostic and therapeutic procedures to detect, treat, and prevent diseases ranging from cancer to AIDS.2 The human genome is only one of almost 100 genomes currently being sequenced around the world. De novo sequencing, sequencing of other organisms, comparative genomics, single nucleotide polymorphism (SNP), and other genome-related issues are examples of applications that will continue to push the limits of DNA sequencing.2 To realize the full potential that genomics holds, the current techniques for DNA sequencing need to undergo further reduction in cost and increase in throughput by integration, automation, and miniaturization of the sample preparation steps prior to sequencing. The clinical use of genomic information is one of the main objectives of the Human Genome Project.2 The entire human genome is estimated to comprise at least 100,000 genes, of which 4000 have already been identified as the causes of known heritable genetic diseases. Use of genomic information will also help pharmaceutical companies create drugs tailored to a patient’s genetic profile, boosting effectiveness while drastically reducing side effects. It could even change our very concept of what a disease is, replacing broad descriptive categories with precise genetic definitions that make diagnosis confident and treatment swift. Advances in molecular biology have allowed the identification of genes and the specific mutations linked with a variety of human diseases. Rapid and cost-effective methods for the detection of such mutations are the basis of genetic diagnosis, which is expected to play an increasingly important role in the fields of molecular pathology and genetics. A powerful technique for the detection of polymorphism is polymerase chain reaction (PCR), which allows the amplification of selected regions of DNA extracted from a variety of sample sources to a detectable level.3 It is also possible to perform multiplexed amplification in cases where multiple mutations are present. Traditionally, DNA used for PCR-based diagnostic analysis has originated from blood, which involves labor-intensive sample preparation. Large-scale DNA polymorphism detection will require the development of new techniques that are fast, cost-effective, and easily automated. Current DNA sequence analysis involves (1) DNA library construction and template preparation; (2) sequencing reaction, separation and detection; and (3) information analysis. The first two parts are the most challenging and the ratelimiting steps in the whole process.4 Since the inception of the Human Genome
Microscale Sample Preparation for DNA Sequencing and Genotyping
31
Project, the individual steps of DNA sequencing technology have improved dramatically. These include the development of bacterial artificial chromosomes (BACs) for longer insert clones, new thermostable enzymes, high-sensitivity dye sets, and perhaps most importantly, highly multiplexed high-speed capillary array electrophoresis (CAE) instruments.5–8
CHALLENGES IN GENOMIC ANALYSIS PLASMID PREPARATION
FOR
DNA SEQUENCING
Many procedures have been developed over the years for isolation of bacterial plasmids.8 Further, several proprietary methods also give satisfactory results. One aspect that nearly all of these methods share is that they involve three basic steps: growth of bacteria, harvesting and lysis of the cells, and purification of the plasmid. All include centrifugation or several treatments of the colonies that are labor intensive and difficult to automate and to interface with CAE. Some chromatographic columns (size exclusion, ion-exchange, high-performance membranes, hydrophobic interaction) have also been developed to avoid the use of centrifugation. All these methods, which may meet the stringent quality criteria for gene therapy, involve high cost and intensive labor. Another complication is that reagents used in the purification of plasmids, such as ethanol and SDS, might become interferences to the subsequent cycle-sequencing reaction. Alternative methods, which require only heat-induced lysis of cells in bacterial colonies, also exist.9,10 Centrifugation or vigorous vortex is still needed to isolate cell debris. The resulting lysate is then used as the template in cycle sequencing using labeled primers. Even though the performance and the ruggedness demonstrated so far by this method are still inferior to that of the standard protocol, the method shows promise for significant savings in time and cost. In fact, a microwave protocol similar to above procedure has already become the preferred method for purification of double-stranded DNA at the Washington University Genome Sequencing Center.11 In its method, the growth of bacterial cultures and subsequent DNA isolation took place in the same 96-well block and no further purification of DNA, by precipitation or other means, was necessary. The 96-well blocks can be reused indefinitely provided they were cleaned between uses. Furthermore, the lysis solution was easily made and was stable at room temperature for a minimum of 3 months, allowing liter-quantity batches to be made and stored. The cost was estimated to be $0.03/sample. This compared very favorably with the cost of commercial preparation methods, which can be as high as $1/sample. Using this approach, the average high-quality sequence length was 427 bases, while 70.52% of the sequences had at least 400 bases of high-quality data.
DNA LADDER PURIFICATION
AND
SAMPLE INJECTION
Capillary gel electrophoresis (CGE) is an attractive technique for DNA analysis because the narrow-bore, gel-filled capillaries provide high-speed, high-resolution separations, as well as automated gel and sample loading. The use of CGE for DNA
32
Analytical Techniques in DNA Sequencing
sequencing was first demonstrated in 1990, when sequencing separations of ~350 bases were obtained in cross-linked gels in ~80 min.12 Much progress has been made in the past decade, and sequencing read-lengths of more than 1000 bases can now be obtained using replaceable gels.13,14 In fact, CGE has eliminated the bottleneck involved in the separation of the DNA ladder produced by the Sanger reaction and has become the key technology for DNA sequencing. Compared with slab-gel electrophoresis, the sample in CGE is injected into the separation capillary instead of being loaded into wells. Therefore, dye-labeled DNA fragments must compete with ions in the sample matrix when they enter the capillary. It is well documented that the performance and reliability of DNA sequencing by CE is sensitive to the quality of the DNA sample due to the employment of electrokinetic injection. Residual salt and dideoxynucleotides in the sequencing sample cause discrimination against DNA because they have higher mobilities. As a result, large variability in signal strength is often observed in CGE. Another problem associated with sample purification is the rehybridization of the single-stranded DNA injected. This causes the mobilities to change and makes base calling difficult. The benefit of stringent sample purification has been demonstrated before.15,16 A poly(ether sulfone) ultrafiltration membrane pretreated with linear polyacrylamide was first used to remove template DNA from the sequencing samples. Then, gel filtration in a spin column format (two columns per sample) was employed to decrease the concentration of salts to below 10 µM in the sample solution. The method was very reproducible and increased the injected amount of the sequencing fragments 10- to 50-fold compared to traditional cleanup protocols. Using M13mp18 as a template, the resulting purified single DNA sequencing fragments could routinely be separated to more than 1000 bases with a base-calling accuracy of at least 99% for 800 bases. A systematic study to determine the quantitative effects of the sample solution components, such as high-mobility ions (e.g., chloride and dideoxynucleotides) and template DNA, on the injected amount and separation efficiency revealed that, in the presence of only 0.1 µg of template in the sample (one third of the lowest quantity recommended in cycle sequencing) and at very low chloride concentrations (~5 µM), the separation efficiency decreased by 70%. The deleterious effect of template DNA on the separation of sequencing fragments was not observed in slab-gel electrophoresis because it was suppressed in the presence of salt at a concentration above 100 µM in the sample solution. The latest results showed that read length up to 1300 bases (average 1250) with 98.5% accuracy can be achieved in 2 h for single-stranded M13 template.17 Thus, the purified DNA ladder dramatically improved the result but at the expense of high cost and manual manipulation. Swerdlow et al.18 first tried to perform DNA sequencing with unpurified DNA sequencing samples. They used a method called base stacking, which allowed direct injection of unpurified products of dye-primer sequencing reactions onto capillaries without any pretreatment. Briefly, on-column concentration of DNA fragments is achieved simply by electrokinetic injection of hydroxide ions. A neutralization reaction between these OH− ions and the cationic buffer component Tris+ results in a zone of lower conductivity, within which field focusing occurs. Without base stacking, a drastic loss in signal was observed for the crude samples. This method can generate separation resolution of at least 0.5 up to 650 bp. The signal strength was
Microscale Sample Preparation for DNA Sequencing and Genotyping
33
excellent relative to conventional injection of highly purified samples. Furthermore, no significant degradation of the capillary performance was observed over at least 20 sequencing runs using this new sample injection method. One shortcoming of this method is that it did not yield satisfactory results with dye terminator chemistry due to the interference of unreacted dye terminators.
PREPARATION
OF
BIOLOGICAL SAMPLES
FOR
PCR
It is interesting that a new PCR method, FoLT (formamide low temperature) PCR, has been developed for reactions directly from whole blood. Formamide solubilizes blood cells and frees the DNA for amplification An important finding was that an alternative DNA polymerase, Tth polymerase, was less sensitive than Taq polymerase to the presence of proteins in blood. All these make PCR directly from blood possible.19,20 Although blood can be used directly in PCR, there is clearly a need for simpler, noninvasive, and more cost-effective means of sample collection, DNA extraction, and genetic diagnosis in general. There are several disadvantages of using blood. First, blood collection can be very inconvenient, because genetic testing often involves analysis of multiple family members. Furthermore, drawing blood can be uncomfortable for the patient and, most important, the handling of blood samples can increase the chances of infection by blood-borne pathogens such as HIV and hepatitis. To date, a variety of alternative sources of DNA have been used for genetic testing including finger-prick blood samples, hair roots, as well as the use of cheek scrapings and oral saline rinses as a means of collecting buccal epithelial cells. The oral saline rinse is perhaps the most extensively used nonblood-based sampling technique. However, it still involves liquid sample handling and requires an additional centrifugation step to spin down the cells, which is difficult to automate and interface with subsequent analysis. By avoiding centrifugation, a simpler method has been developed and validated by using just swabs and brushes.21 The buccal cells were collected on a sterile brush by twirling the brush on the inner cheek for 30 s. Although still requiring a neutralizing step later, this method is generally easy and very reliable. In a blind study comparing the analysis of 12 mutations responsible for cystic fibrosis in multiplex products amplified with DNA from both blood and buccal cell samples from 464 individuals, there was 100% correlation of the results for blood and cheek-cell DNA. The success rate of PCR amplification on DNA prepared from buccal cells was 99%. This method has also been used to analyze DNA for genetic polymorphism by matrix-assisted laser desorption/ionization mass spectrometry.22
TOTAL SYSTEM INTEGRATION Numerous endeavors have been made in developing robotic workstations to perform sequencing reaction, purification, preconcentration, and sample loading. Although robotics has shown advantages in repetitive operation with high precision, the adaptation to highly multiplexed capillary array separation interface suffers from many incompatibilities in terms of the total reaction volume, purification by centrifugation, and sample injection. Online microfluidics systems based on either capillaries or microchips hold promise for the next generation of totally automated DNA sequencers.
34
Analytical Techniques in DNA Sequencing
Capillary Microfluidics Systems In capillary microfluidics,23 dye-labeled terminator cycle sequencing reactions are performed in a 250 µm i.d. fused-silica capillary, which was placed into a hot-air thermal cycler. After PCR was completed, the reaction mixture was transferred online to a size-exclusion column to purify the reaction product from the unreacted dye terminators. The purified product was then injected through a cross into a gel-filled capillary for size separation. This system was closed and the operation was reliable since no moving parts were involved. Cleaning of the system with 0.1 M NaOH was required to remove cross-contaminants before reuse. The sequence could be called from 36 to 360 bases with an accuracy of 96.5% using in-house software. By manual editing, the accuracy improved to 98% for 370 bases. Later on, a multiplexed system based on above scheme was developed in which eight DNA sequencing samples could be processed simultaneously starting from template to called bases.24 The major achievement in the instrument was the use of freeze/thaw switching valves instead of rotary valves, which were unsuitable for multiplexed systems due to their size. For all eight processed samples, sequences could be called up to 400 bases with an accuracy of 98%. PCR analysis directly from blood was also demonstrated with a similar flow management concept.25 Another fully integrated single capillary instrument comparable in design has also been designed and prototyped.26 The reaction was performed inside Teflon tubing. The purification and separation columns were interfaced through a simple T-connector instead of a cross. The instrument was reliable and fast, performing PCR reaction cycling, purification, and analysis all in 20 min. Adaptation of the instrument prototype for separation of DNA-sequencing reactions was described; cycle sequencing and electrophoresis of a single lane were complete in 90 min with base calling to beyond 600 bases. Miniaturization of the online system will reduce the cost of DNA sequencing substantially below current levels because only 1/100 of the reagent is required for actual CE. Soper et al.27 developed a miniaturized solid-phase cycle sequencing reactor coupled with CE. The nanoreactor consisted of a fused-silica column with a total volume of 62 nl. Biotinylated DNA template was bonded to the surface by biotinstrepavidin–biotin linkage. The main disadvantage of this scheme is the loss of template surface coverage. One solution for reactivation of the nanoreactor could be through adding fresh streptavidin and new biotinylated target DNA. The read length for a single-color run was approximately 450 bases. The system is considered amenable to automation even though there is still manual operation in the published design. Online Microchip Systems Microchips provide a new platform for integration with unique electro-osmotic pumping and nonmechanical valves. A true nano-total analysis device was developed by Burns et al.28 who used microfabricated fluidic channels, heaters, temperature sensors, and fluorescence detectors to analyze nanoliter-size DNA samples. The device is capable of starting with 100 nl reagent and DNA solution, online mixing, amplifying
Microscale Sample Preparation for DNA Sequencing and Genotyping
35
or digesting the DNA to form discrete products, and separating and detecting those products in microfabricated channels. No external lenses, heaters, or mechanical pumps are necessary for complete sample processing and analysis. The components have the potential for assembly into complex, low-power, integrated analysis systems at low unit cost. Microchips still need to overcome some technical difficulties before they can be routinely utilized. These include solvent evaporation and interface with the outside bioanalysis laboratory where the common working volume is µl. Litborn et al. described using a closed humidity chamber to address the problem of solvent evaporation.29 Later, they reported an improved technique for performing parallel reactions in open, 15-nl volume, chip-based vials. The evaporation of solvent from the reaction fluid was continuously compensated for by addition of solvent via an array of microcapillaries. Their results showed that the concept for continuous compensation of solvent evaporation should be applicable to reaction volumes down to 30 pl.30 There are other approaches to avoid the problem of solvent evaporation. Soper developed a hybrid system that coupled nanoliter sample preparation to PMMA (polymethylmethacrylate)-based microchips.31 Unlike standard sample preparations that are performed off-chip on a µl scale, true integration was demonstrated at nl volumes. An integrated system for rapid PCR-based analysis on a microchip has also been demonstrated recently.32 The system coupled a compact thermal cycling assembly based on dual Peltier thermoelectric elements with a microchip gel electrophoresis platform. This configuration allowed fast (~1 min/cycle) and efficient DNA amplification on-chip follo- wed by electrophoretic sizing and detection on the same chip. An unique on-chip DNA concentration technique based on adsorption and desorption has been incorporated into the system to reduce analysis time further by decreasing the number of thermal cycles to 10 cycles, or 20 min for DNA amplification and subsequently detection.
CAPILLARY ARRAY INSTRUMENTS In 1992, Mathies’s group developed this approach to address the throughput requirement of genomic analysis.6 They constructed a confocal fluorescence scanner and demonstrated DNA sequencing in 25 parallel capillaries. Since then, additional improvements in optical design and separation matrixes have made the commercialization of CAE sequencers possible. Today, there are four commercial versions of CAE instruments. PE Biosystems has developed the ABI PRISM 3700 DNA analyzer. This 96-capillary array instrument is based on the approaches of Kambara8 and Dovichi.7 In this instrument, DNA sequencing fragments are detected in a sheath flow and spectrally resolved using a concave spectrograph and a cooled charged coupled device (CCD) camera. Bare capillaries are used with dynamic coating, which is stable for more than 300 runs. The turnaround time is roughly 2.6 h with 600 bp in 120 min. The Molecular Dynamics instrument MegaBACE 1000 is based on confocal detection after Mathies’s group.6 A microscope objective is used to focus the laser light inside the capillaries and, at the same time, collect the emitted light from the center of the column. The lifetime of the instrument may be limited by mechanical
36
Analytical Techniques in DNA Sequencing
stress of moving the scanner when fast sampling rates are required. The system uses linear polyacrylamide (LPA)-coated capillaries, which are stable for 200 runs. The average sequencing data is 500 bp and the turnaround time is less than 2 h. Beckman Coulter has entered the market with an 8-capillary array design, the CEQ 2000 DNA analysis system. The optical design of this instrument is similar to that of Molecular Dynamics except that separate excitation and emission paths are used. It features four-color IR dideoxy-terminator chemistry. On-column detection is the approach implemented in the SpectruMedix instrument that is based on our work.33 The laser beam crosses all 96 capillaries after the laser is expanded by a cylindrical lens. The fluorescent light is collected at right angles from the laser axis and detected by a CCD camera. Because no moving parts are involved in detection, the optic design is very rugged. Bare fused-silica capillaries are used with dynamic coating with a hydrophobic polymer. The turnaround time is 2 h with average base calling of 500 bp. The SpectruMedix system is also employed in the new 16-capillary ABI 3100 and 96 capillary 3710 sequencers. Alternatives in system design mainly concern illumination and detection. Kambara’s group34 further tested side illumination with detection on column. For this design, the number of capillaries in an array is generally limited by laser-power attenuation along the array due to reflection and divergence. They overcame these problems by placing the capillaries in water and adding glass-rod lenses between the capillaries. As a result, up to 45 capillaries could be simultaneously irradiated with a single laser beam and the fluorescence from all the capillaries could be detected with high sensitivity. Quesada and Zhang35 took another approach for a multiple capillary instrument by the use of optical fibers for illumination and collection of the fluorescence in a 90° arrangement. A subsequent version of this instrument utilized cylindrical capillaries as optical elements in a waveguide, where refraction confined a focused laser beam to pass through 12 successive capillaries in a flat parallel array.36 However, larger capillary arrays are limited by the refractive effects that spread the light along the length of the capillaries. Handling more than 96 capillaries is very challenging and several groups have attempted to address this problem by modifying existing designs. Dovichi’s group used sheath-flow detection and a novel two-dimensional arrangement that can hold up to 576 capillaries.37 A prototype 384-capillary array electrophoresis instrument has also been developed for higher throughput analysis by SpectruMedix. Their instrument design is based on the 96 capillary platform with a redesign in the camera lens. Mathies and coworkers have also continued to push the limit of the confocal system. They have developed a system with the capillaries aligned in a circular array. The microscope objective spins inside a drum, illuminating the capillaries one at a time. They have shown sequencing data from 128 capillaries, but a larger number of capillaries could be easily accommodated in this geometry.38,39 A totally different platform to perform CAE is the microchip. The first demonstration of CAE in microchip was by Mathies’s group for genotyping.40 A microplate that can analyze 96 samples in less than 8 min was produced by bonding 10 cm diameter micromachined glass wafers to form a glass sandwich structure. The microplate had 96 sample wells and 48 separation channels with an injection unit that permitted the serial analysis of two different samples in each channel. An
Microscale Sample Preparation for DNA Sequencing and Genotyping
37
elastomer sheet with an 8 × 12 array of holes was placed on top of the glass sandwich structure to define the sample wells. Samples are addressed with an electrode array that makes up the third layer of the assembly. Detection of all lanes with high temporal resolution was achieved by using a laser-excited confocal fluorescence scanner as described above. An SNP typing assay has also been developed and evaluated in a microfabricated array electrophoresis system.41 That study demonstrates the feasibility of using allele-specific PCR with covalently labeled primers for high-speed fluorescent SNP typing. DNA sequencing on the microchip array is very interesting and challenging. Early studies of single channel on a chip required channel lengths comparable to capillaries. Making many turns in a chip also proved to be deleterious to separation performance. It also implies that a larger-diameter chip is needed for DNA sequencing.42 Recent results show that there is still much room for improvement. Liu et al.43 demonstrated DNA sequencing by 16 channel CAE in a microchip format. Samples are loaded into reservoirs by using an eight-tip pipetting device, and the chip is docked with an array of electrodes. Under computer control, high voltage is applied to the appropriate reservoirs in a programmed sequence that injects and separates the DNA samples. An integrated four-color confocal fluorescence detector automatically scans all 16 channels. The system routinely yields more than 450 bases in 15 min in all 16 channels. In the best case using an automated base-calling program, 543 bases have been called at an accuracy of >99%. Separations, including automated chip loading and sample injection, normally are completed in less than 18 min. This demonstrates the potential of the microchip as the next generation CAE platform.
EMERGING TECHNOLOGIES SEQUENCING DIRECTLY
FROM
SINGLE BACTERIAL COLONIES
The small diameter of capillaries coupled with ultrasensitive detection associated with laser-induced fluorescence in CE can reduce the sample requirement from 1 to 10 fmol of DNA in a given band on the slab gel to 1 to 10 amol in capillary gel.44 This means we can reduce the reaction volume from 20 µl to 20 nl if the reaction efficiency is maintained and an efficient sample-loading method can be found.27 However, present sequencing technology still leaves much to be improved if the potential for genomic science is to be fully realized. The front end of the sequencing process, especially sample preparation, which is typically labor intensive, repetitive, and time-consuming, needs to interface smoothly with the back end.45 In a recent study,46 we show that the implementation of colony sequencing in our multiplexed online reaction–purification-sequencing instrument is feasible. Bases can be called directly from a single colony without compromise in spite of the complex matrix of the cell lysate and the small size of the sample. This completes the long-sought-after goal of integration and automation of the front and back ends of sequencing in one instrument. The experimental setup is similar to that described previously.23,24 Escherichia coli DH5α competent cells and plasmid pUC19, Plasmid Bluescript, and pGEM were used. Cell transformation was according to the protocol provided by Clontech.
38
Analytical Techniques in DNA Sequencing
Transformed cells were plated on 2 × TY agar plates and incubated at 37°C for 24 h. A colony was picked up by a wire loop and put into a vial with 15 µl autoclaved deionized water inside. After heating at 96°C for 11 min, sequencing premix (8 µl), BSA (2 µl, 2.5 mg/ml), and 3.2 pmol primer were added. Then, 20 µl of the above solution was aspirated into the reaction capillary. Cycle sequencing began immediately by holding at 96°C for 3 min, followed by 40 cycles (96°C for 10 s, 50°C for 30 s, and 60°C for 4 or 2.5 min). Three different sets of dyes, Rhodamine, dRhodamine, and Energy Transfer, and two polymerases, AmpliTaq FS from ABI and ThermoSequenase from Amersham Life Science, were used in the reaction. Performance in all cases is comparable. For the results presented here, dRhodamine terminators and AmpliTaq FS were used. After reaction, the sequencing ladders were purified by homemade size-exclusion columns (SEC) and injected online into the separation capillary, or purified by spin columns and injected off-line for comparison. Three features associated with the combined lysis/reaction protocol may cause the difference in efficiency. First, cells in the colony are still viable. The enzyme they produced if not deactivated may interfere with the polymerase. In PCR reactions, the cells can be lysed in the reaction buffer because the exponential amplification effect can compensate for the loss caused by this kind of interference. This is not the case for the linear amplification character of cycle sequencing. Second, we suspect that the small inner diameter of the capillary reactor prevents uniform distribution of the plasmids. Cells in colonies tend to stick together even after being drawn into the capillary. After heating, the released plasmids localize in a confined region of the long capillary despite 10 min heating at 96°C. Convection here is small, so the molecular movement is dominated by diffusion. For a diffusion-controlled process, mixing may be taken as nearly complete for Dt/l2 from 0.1 to 1. The diffusion constant for rhodamine-dGTP in water at room temperature is D = (3 – 5) × 10–6 cm2/s.47 Accounting for the increase in diffusion caused by temperature and viscosity at 96°C,48 the effective mixing distance in t = 10 min even for small molecules is thus less than l = 1 cm. The aspiration speed used to load the mixture to the reactor was 2.4 cm/s, which corresponds to a Reynolds number of roughly 12. The flow will therefore be laminar and no extra mixing exists.49 The third reason may relate to the thermal stability of the enzyme. Taq polymerase is thermostable with a half-life of 40 min at 95°C and 10 min at 97.5°C, respectively. The extra heating time for lysis may cause the enzyme to lose some activity. Adjusting the parameters of cycle sequencing was vital to success. Compared to the standard recommended protocol, we use somewhat longer annealing times (5 to 30 s) to assure the correctness and completeness of annealing between the primer and the plasmid to minimize interference from chromosomal DNA and RNA. The total signal strength may also benefit from this, as there should be an increase in the amount of primed template.50 The signals among the four bases were balanced, so no adjustment of ratio of ddNTP/dNTP was necessary. The sequencing reaction kinetics do not appear to be affected by the complex matrix. Reducing the extension time from 4 to 2.5 min was shown to be possible. Extension was also tested at temperatures higher than 60°C, where the Taq enzyme is supposed to have a faster polymerization rate. Similar results were obtained.
Microscale Sample Preparation for DNA Sequencing and Genotyping
39
The lysate of E. coli is a very complicated matrix, which contains salts, proteins, and other biomolecules. Surprisingly, we did not find any extra problems in injection. Presumably these are greatly diluted during the elution process. The Sephadex beads can retain some of the biomolecules such as degraded RNA, lipids, polyamine, and lipopolysaccharide, as long as the molecular weight is less than 5000 Da. There are still some high-molecular-weight molecules that may elute with the DNA ladder. In fact, the carrier protein BSA (10–11 mol) that is added to the reagents may co-elute also. Each E. coli cell may contain 2,350,000 protein molecules so one colony with 107 to 108 cells will result in another 10–11 mol of protein being added to the reaction mixture. As with our earlier experiments, we did not observe any deleterious effect related to injection because of BSA. For BSA the isoelectric point is 4.7 and the molecular weight (MW) is 67,000, which is roughly the MW of 200-bp ss-DNA. But the net charge per molecule at pH 7.4 is only –17, much smaller than a 200-bp ss-DNA. This results in a mobility of BSA that is at least one order of magnitude smaller than DNA. More importantly, by long-time heating, a high fraction of BSA will be polymerized and aggregated and are thus further discriminated against in electrokinetic injection. We also note that the observed interference of BSA to DNA separation is buffer dependent.51 Urea used in the sequencing buffer may also help to reduce the interaction between the protein and DNA. In the reconstructed image plot of the sequencing results from six experiments in a 1-week period, the intensity was not uniform because different DNA samples were used. Generally, the intensities from purified DNA (40% of the channels) are two times higher than the intensities from the lysate. But even the raw data starting directly from the lysate provide adequate signal-to-noise ratios for base calling. Two clones, PGEM and M13mp18, were used in these experiments. The former has known problems with compressions, but the use of 7 M urea here provided excellent separation even at room temperature. Among all 48 runs, only two runs did not produce a useful sequence due to bubble formation at the cross and one run produced only a short sequence (150 bp). All three appeared in the same channel. These intensities are, however, still reasonable, indicating that injection rather than reaction was the culprit. Two runs provided sequence around 350 bp, and the electropherogram of all others provided resolution greater than 0.5 well beyond 430 bp. The turnaround time for each run is 0.2 h for lysate preparation, 3.5 h for reaction, 1 h for regeneration of the system, and 2.5 h for separation. With staggered operation of these individual steps analogous to an assembly line, the turnaround time will be essentially the reaction time, which can be reduced to 2.5 h even with lysates as the template. During these experiments, the reactors and SEC columns were regenerated by washing between runs with 1 × TE and water. No memory effect was observed in the different channels. Figure 3.1 shows the base-calling results (raw data, day 6, bottom channel) up to 620 bp with 98% accuracy. The resolution after 620 bp is still above 0.5. Base calling was accomplished by software written in Labview using the two-color scheme developed before.52 Longer reads can be expected with more sophisticated algorithms. Loss in the front part of the sequence may be due to the long injection time in diluted buffer. This can be solved by a better design of the cross assembly (to fully sweep the volume inside the cross) to allow more efficient injection. This is not a problem in shotgun sequencing because for the EcoR.I and
40
Analytical Techniques in DNA Sequencing
FIGURE 3.1 (Color Figure 3.1 follows page 84.) Sequencing of a DNA insert in the pBluescript vector using the cell lysate from one colony as the template. Primer: M13-40. The raw data from the blue and red channels are plotted. The miscalls are also corrected under the corresponding bases. The resolution is above 0.5 at 620 bp.
the universal primer, which are widely used, the vector sequence is around 100 bp. For primer walking, such a limitation will need to be considered. A major advantage of the present system is the potential for further multiplexing and miniaturization. Multiplexing 100 channels using freeze–thaw valves can be manageable even in the present assembly. By reducing the inner diameter yet keeping the same reagent concentrations, even smaller volume samples could be injected using the current protocol. Our instrumentation therefore promises to further reduce the reagent cost and labor requirement in high-throughout DNA sequencing.
Microscale Sample Preparation for DNA Sequencing and Genotyping
SEQUENCING BASED
ON
41
NANOLITER REACTION VOLUMES
Sample Manipulation Miniaturization of cycle sequencing in a glass capillary27,48,53,54 has been demonstrated at the microliter level. Moving the cycle-sequencing reaction into a capillary has the additional advantage of increasing the reaction speed due to the small heat capacity of a capillary vs. a heating block or a water bath. A capillary reactor is also compatible with highly multiplexed electrophoresis in a parallel capillary array. Several groups23,26 have demonstrated online reaction in a capillary coupled with electrophoretic separation. Multiplexed systems also have been demonstrated.24,25,46 However, they did not exploit the small amount of DNA sample required for CE separation. A microchip providing integrated operation from Sanger reaction to sequencing separation is a promising approach.28,55,56 Evenson et al.57 demonstrated that by using a piezoceramic actuator we can rapidly mix two 1-µl solutions in under 3 s inside a capillary. However, that system may pose a challenge for multiplexed operation. The real issue is whether we can prepare small-volume solutions and deliver these to the reaction zone for the cycle-sequencing reaction, purify (if necessary), and then inject them for CE separation. If we need to premix the reagent with the template on a microliter scale before introducing into the reaction zone, large amounts (1 µl) of reagent would be wasted even when only a small volume (50 nl) is injected into the capillary for electrophoresis. The work presented here58 describes an automated nanoreactor for cyclesequencing reaction with online SEC purification and capillary gel electrophoresis. As little as 25 nl reagent volume was required. A simple procedure allows the reagent solution to mix with the template solution inside the nanoreactor. By using this protocol, the bulk reagent solution can be reused without contamination. This provides real cost savings based on the amount of reagents used. A simple and inexpensive flexible heater design for the nanoreactor allows for future scale-up for capillary-array DNA sequencing. Either the ABI PRISM dye terminator cycle-sequencing ready reaction kit with AmpliTaq DNA polymerase FS or the ThermoSequenase dye terminator cycle sequencing premix kit was used; 0.05 µg/µl M13mp18 ssDNA in 50 mM Tris, 2.5 mM HCl, 2 mM MgCl2, and 1 × BSA as stock solution was used. The reaction mixture for AmpliTaq FS polymerase consisted of 8 µl of terminator ready reaction mix, 3.2 pmol universal –21 M13 primer, and 2 µl 10 × BSA. The reaction mixture for ThermoSequenase consisted of 8 µl of terminator ready reaction mix, 5 pmol universal –17 M13 primer, and 2 µl 10 × BSA. These are prepared in advance and a 0.5-µl aliquot was used for a series of reactions. The temperature protocol for the AmpliTaq cycle-sequencing reaction was as follows: the reaction mixture was heated to 95°C and held for 2 min; 35 thermal cycles were performed with denaturation at 96°C for 10 s, annealing at 50°C for 15 s, and extension at 60°C for 4 min. Then the sample was ramped to 95°C and held for 2 min. When ThermoSequenase cycle-sequencing reaction was used, the annealing temperature was adjusted to 45°C. Figure 3.2 shows the schematic diagram for the instrumental setup. The system consists of a nanoreactor system, an SEC system, and a CE electrophoretic system
42
to gas tank
distribution valve µ-LC pump 1X TE buffer
with 7M urea buffer
temperature controller
freeze-thaw valve
CE capillary
temperature controller
column heater
buffer flow switching valve
power supply
+
buffer
FIGURE 3.2 Schematic diagram of the experimental setup. Samples and reagents are introduced from the lower left and transported from left to right for reaction and then separation.
Analytical Techniques in DNA Sequencing
two-position valve
Microscale Sample Preparation for DNA Sequencing and Genotyping
43
with gel filling. A microtee was used to connect the nanoreactor system, SEC system, and the pumping system, which consisted of a syringe pump and a µLC-500 pump. A two-position valve was used to selectively connect one of the pumps to the nanoreactor or the SEC column. A microcross was used to connect the SEC system, gel capillary electrophoretic system, and the syringe pump. The syringe pump was equipped with a 25 µl syringe with a resolution of 0.52 nl per step. An 8-position multiposition valve was used in conjunction with the syringe pump to allow the selection of different solutions to pump through the reactor capillary for cleaning or to the microcross for CE separation. The nanoreactor was constructed with layers of brass sheet (7.5 × 2.5 × 0.025 cm) and a Kapton insulated flexible heater (7.5 × 2.5 cm, 2 W/cm2, resistively heated). A thermal epoxy was used to bond the brass sheet and the flexible heater together. This nanoreactor has a very small thermal mass since the total thickness excluding the capillary reactor is ~300 µm so that it allows the temperature to change rapidly. The length (7.5 cm) of the heater allowed the use of 8 capillaries (9-mm spacing is the standard 8 × 12-tray format) or 16 capillaries (4.5 mm spacing for the 384-tray format) for simultaneous reactions. A 10-cm-long, 360 µm o.d. and 75 µm i.d. capillary was placed in between two brass sheets. A silicone heat sink compound was applied onto the capillary surface and in between the brass sheets to ensure proper heat transfer. For the 75 µm i.d. capillary, the 23 mm reaction length corresponds to ~110 nl maximum reaction volume. We could simply change to different inner diameters to accommodate different reaction volumes. A 0.08 cm diameter bare K type thermocouple was used to monitor the temperature of the nanoreactor. This thermocouple was inserted into a 250 µm i.d., 360 µm o.d. capillary in which water was filled and both ends of the capillary were sealed. The thermocouple was position ~0.5 cm away from the reaction capillary. A PID temperature controller was used to set the temperature profile for cycle sequencing. A computer was used to communicate with the temperature controller to effect the temperature change and duration. In this way, ±0.5°C accuracy can be obtained and the heating rate was ~3°C/s. A room-temperature nitrogen gas jet, which was controlled by a solenoid valve, was directed to the heater to lower the temperature quickly during the transition from denature to annealing conditions. When ~5 psi gas pressure was used, ~3°C/s cooling rate can be obtained. A faster cooling rate can be obtained by using a higher gas flow rate, but slight overshoot may occur. For capillary cleaning, 250 µl of 1 × TE buffer was first pumped through the reaction capillary by the syringe pump. Then 200 nl of 50 mM Tris, 2.5 mM HCl, and 2 mM MgCl2 solution was aspirated into the capillary reactor followed by aspiration of 50 nl of cycle-sequencing reaction mixture at 21 nl/s (Figure 3.3, left). The Tris solution was used as a buffer zone to isolate the reaction solution from the TE separation buffer since EDTA will interfere the cycle-sequencing reaction. To add the sample, 500 nl template was placed in a microcentrifuge tube. The tip of the reaction capillary was placed into the bottom of the tube. The syringe pump first aspirated 100 nl of the template solution (Figure 3.3, middle) and then dispensed 100 nl (Figure 3.3, middle). This mixing procedure (last two steps) was repeated 12 times to allow complete mixing of the reaction mixture and the template solution. The bulk of the premix reagents was thus maintained inside the capillary throughout
44
Analytical Techniques in DNA Sequencing
nanoreactor
180 nl to the nanoreactor
50 nl reaction mixture
100 nl template
12 times
FIGURE 3.3 Schematic diagram of the solution mixing procedure. (Left) 50 nl of reagent mixture was introduced. (Middle) The pump was cycled 12 times to aspirate and then redispense 100 nl of template solution. (Right) After such mixing, 180 nl total volume was taken up for reaction.
this procedure. After the mixing, the reaction solution was moved up to the nanoreactor by aspirating an additional 180 nl of solution while the capillary tip was still positioned in the template tube (Figure 3.3, right). By aspirating a dye solution into the capillary with a syringe pump for a fixed time period, we can visually determine how accurately the syringe pump could function. It was found that we can easily aspirate 25 nl of the solution into the 75 µm i.d. capillary with ~10% error. Although only a 10-cm length of capillary was used for the nanoreactor, there was a time delay on the fluid movement due to friction. Therefore, between each syringe pump action, a 6-s waiting period was added to ensure that the fluid completed the motion. To evaluate the mixing procedure, 50 nl (corresponded to 1 cm in length) of concentrated Rhodamine 6G solution was aspirated into the capillary. After mixing with water following the above mixing protocol, the dye solution spread out to ~2 cm. Although this mixing procedure may not provide uniform distribution of the reagent, primer, and template across the entire reaction zone, the cycle-sequencing reaction is relatively robust and tolerates such a variation. For further testing, a series of 10, 12, 14, and 16 mixing cycles was used to determine the cycle-sequencing efficiency by observing the fluorescence signal after the SEC separation. It was found that 12 mixing cycles provided the largest DNA signal under these reaction conditions. The initial template concentration also played a role on the reaction efficiency. A range of concentrations from 0.2 µg/µl to 0.025 µg/µl was used to determine the cycle-sequencing reaction efficiency. It is found that 0.05 µg/µl template concentration provides the highest efficiency.
Microscale Sample Preparation for DNA Sequencing and Genotyping
45
A freeze–thaw valve, which was described previously,24 was positioned at the entrance end of the reaction capillary to close it during the cycle-sequencing reaction or SEC separation. During the reaction, TE buffer was flowed through the SEC system to condition the column and to pressurize (>60 psi) the nanoreactor to eliminate bubble formation. After the reaction capillary was cleaned, the reagent mixture was aspirated into the capillary followed by mixing with the template solution with the procedure described above. The freeze–thaw valve was closed followed by switching the twoposition valve so that 1 × TE effluent can flow through the SEC column for conditioning during the cycle-sequencing reaction. Before the reaction was completed, TBE buffer, PVP coating solution, and PEO gel was filled into the electrophoretic capillary in preparation for the CE separation. After the cycle-sequencing reaction, the nanoreactor was heated up to 95°C for 2 min for denaturing the DNA products. Then the two-position valve was switched back to connect the syringe pump to the nanoreactor. The freeze–thaw valve was opened and allowed the aspiration of an additional 800 nl 1 × TE solution to move the reaction products over the microtee. The freeze–thaw valve was closed and the two-position valve was switched back to connect the µ-LC pump to the SEC column to push the reaction products into the SEC column for purification. Fluorescence from the SEC column was monitored. A positive high voltage was applied at 60 V/cm field strength when the DNA signal appeared at the first detector (~10 s delay time due to the 38-cm-long connection capillary). Then, 30 s later, the field strength was increased to 120 V/cm for 60 s followed by a decrease in the field strength to 60 V/cm for the remaining injection period. The total injection time was ~3 min. Stacking occurs during the entire period. After injection, the two-position valve was switched to disconnect the µ-LC pump and the SEC column to stop the flow of the effluent into the microcross. Otherwise, the dye-labeled terminators will continuously pump through the microcross and subsequently become injected into the CE column. The syringe pump then delivered 1 × TBE with 7 M urea buffer to the microcross at a flow rate of 1.3 µl/min for the CE separation. The field strength for the CE separation was set at 120 V/cm. Figure 3.4 shows the electropherogram of the cycle-sequencing products from M13mp18 DNA template after nanoreaction followed by SEC purification with onewavelength excitation and dual wavelength detection. Here, 50 nl reaction mix was aspirated initially for cycle-sequencing reaction. No dye-labeled ddNTPs interference can be observed. The success rate is 100% over 15 consecutive runs. Good signal-to-noise ratio and separation resolution were obtained from the electropherogram with a DNA read length of over 450 bp using an in-house two-wavelength intensity ratio scheme.52 Future implementation of multiwavelength base calling will significantly extend the read length. Miniaturization of the injection region will also provide better signal-to-noise ratio for base calling. It is interesting to see that no denaturing is necessary during the sample injection period. It is possible that when the reaction plug moved over the microtee into the SEC column, sufficient dilution of the reaction plug prevented the DNA from renaturing. As little as 25 nl reaction mix can be used in this system with slightly compromised read length due to a lower signal-to-noise ratio. The mixing procedure was altered
46
Analytical Techniques in DNA Sequencing
Fluorescence
400 bp
AGCAAGCGG TCCACGCTGG T T TG CCCCAGCAGGCGAAAATCCTGTTTGATGGTGGTTCCGAAATCGGCAAAATC
45
110
180
Time (min)
FIGURE 3.4 Electropherogram of DNA fragments after cycle-sequencing reaction for M13mp18 ss-DNA template amplified by AmpliTaq polymerase inside the nanoreactor with purification by SEC followed by online injection into the CE column. Only one wavelength channel was shown for clarity; 120 V/cm field strength with 50 cm effective length was used for CE separation.
slightly to accommodate the smaller uptake volume. Only 60 nl aspirate-dispense mixing cycle was used. The electropherogram still allowed base calling up to 380 bp. To reduce the cost of the primers rather than the sequencing reagents, instead of putting the primer into the ready reaction mixture, we can premix the template with the reaction solution. In this case, 0.4 µg of M13mp18 template was added to the ready reaction mix. The primer stock solution was 0.6 µM. The primer was then mixed with the reaction solution later inside the nanoreactor (Figure 3.3, middle). Such a protocol will be desirable whenever the primer is the expensive component. In this way, we can simply use a different primer for multiple sequencing to implement, for example, the primer-walking scheme.59 We found no apparent difference in the reaction efficiency and the sequencing separation up to 450 bp in this “primermixing” procedure. However, the signal is reduced significantly (3×) afterward and no compression peak can be observed. The use of 500 nl template volume is convenient for standard microvials. If a smaller sample tube such as those used in the 384-tray format is used to hold the reagent solution and a 150 µm o.d. capillary is used as the nanoreactor, only ~150 to 200 nl solution volume is necessary for the operation in Figure 3.3. In the reaction
Microscale Sample Preparation for DNA Sequencing and Genotyping
47
solution, ~60% of the volume (30 of 50 nl) is the expensive ready reaction premix solution containing dye-labeled terminators and enzyme. In the standard reaction protocol, 4 µl of premix solution is used in a total of 10 µl reaction volume. More than 130-fold reduction in reagent used is thus achieved. Even compared to the stateof-the-art 1 µl reaction volume protocol,48,53,54 more than 13-fold reduction is obtained. The turnaround time for this integrated system was ~6 h including 3 h for cyclesequencing reaction, 10 min for the SEC separation, and 3 h for CE separation. If an additional syringe pump is employed to provide the flow during CE separation, the next round of cycle-sequencing reaction can be performed while the first round of separation is taking place. This will cut the turnaround time by half. The cyclesequencing time can in principle be reduced to 30 min.26 Here we are limited by the heating rate and the cooling rate of our heater. The separation speed can also be increased to allow sequencing in 30 min.60 Online Sample Purification The above system is also quite complicated as a result of the use of pressure-driven fluidics, which is required by the SEC purification column. The SEC column also introduces substantial dilution prior to injection into the CGE capillary. Here,61 a simple, miniaturized, and integrated online sample preparation system is developed for DNA sequencing at the scale of nanoliters. The whole system features the use of CZE for purification of the cycle-sequencing products, the integration of nanoreactor and CZE in one capillary, and online coupling of CZE with CGE. Modifications to the original cycle-sequencing reaction mixture developed for ABI Model 9600 thermocycler were made to fit the small-volume reaction in the capillary. A typical 20- µl reaction mixture was composed of 2 µl of 2.5 mg/ml BSA, 1 µl of 20 mM MgCl2, 2 µl of 5 µM 40M13 (5´-GTTTTCCCAGTCACGAC 3´) universal primer, 3 µl of 0.2 µg/µl ss-DNA (M13mp18) or 5 µl of 0.2 µg/µl dsDNA (pGEM) in 1 × TE buffer (pH ~ 7.5), 8 µl of sequencing reagent premix, and 4 µl of deionized water. The reagent premix consists of 125 mM Tris-HCl, pH 9.5, 5 mM MgCl2, 1.25 mM dITP, 0.25 mM each dATP, dCTP, dTTP, ddATP (dyelabeled), ddCTP (dye-labeled), ddGTP (dye-labeled) and ddTTP (dye-labeled), Thermo-Sequenase DNA polymerase, Thermoplasma acidophilum thermostable inorganic pyrophosphatase (TAP), Nonidet P40, Tween 20 and 6.25% glycerol. Figure 3.5 is a schematic diagram of the entire instrumental setup. The capillaries C1 and C2 were first conditioned by 1 M NaOH, deionized water, and THM buffer. Before loading cycle-sequencing reaction mixture, the liquid level in R1 and R2 were equilibrated for 20 min by using a wide-bore plastic tube (30 cm × 3 mm i.d.) filled with THM buffer to connect R1 and R2. R1 and R2 remain connected during cycle sequencing. In addition, the liquid level in R3 was also manually adjusted to the same level as that in R2. This was to ensure that hydrodynamic flow in the three capillaries was nearly zero, and the small-volume reaction mixture stayed in the same location in the capillary during the entire period (∼2.5 h) of reaction. A small volume of reaction mixture was introduced into the reaction region in the thermocycler by hydrodynamic injection followed by a plug of THM buffer. The
48
Analytical Techniques in DNA Sequencing
A/D
PMT1
Controller LPF1 Heating tape
C1
Air pump
PMT2
MO1 A B
C3
Laser
C
L1 Laser
L2 C2
M1
M2
TC
LPF2
Cartridge
PMT3
MO2
MO3
NF
GND2
GND1 R1
R2 HV1
GND1
R3 HV2
GND2
FIGURE 3.5 Schematic of the integrated online cycle-sequencing-CZE-CGE system. TC, thermocouple; C1 and C2, CZE capillaries; C3 CGE capillary; R1, R2, and R3, buffer reservoirs; HV1, negative-voltage power supply; HV2, positive-voltage power supply; GND1 and GND2, grounded lines for HV1 and HV2; L1 and L2, lenses; MO1, MO2, and MO3, microscope objectives; LPF1, 550-nm long-pass filter; LPF2, 610-nm long-pass filter; NF, 543-nm notch filter; M1 and M2, mirrors; PMT1, PMT2, and PMT3, photomultiplier tubes; A/D, data acquisition board.
distance between the inlet tip and the reaction region was ca. ∼3 cm. The reaction volume was in the range of 90 to 120 nl with corresponding length in the range of 2 to 3 cm. The temperature protocol for the on-column cycle-sequencing reaction was adjusted to the following: the sample mixture was heated to 96°C and held for 1 min; 35 cycles were performed with denaturation at 96°C for 10 s, annealing at 45°C for 5 s, and extension at 60°C for 3 min; then the temperature was ramped to 96°C and held for 2 min. After the cycle-sequencing reaction, the wide-bore plastic tube was removed from R1 and R2. A negative high-voltage power supply was used to drive electrophoresis for purification from the anode (R1) to the cathode (R2). Note that the anode in R1 should be grounded to avoid electrical arcing in the µ-thermocycler when the high voltage is applied. Also, the electrode in R3 needed to be removed from the buffer during the CZE separation. Otherwise, the current in the CZE capillary will be seriously affected even if HV2 was not applied. During CZE separation, dye-terminators passed the detection window first. Once the DNA fragments were detected by PMT1, timing was initiated. When the peak of the DNA fragments was expected to go past the tee and
Microscale Sample Preparation for DNA Sequencing and Genotyping
49
enter capillary C2 (based on observed time to the detection window extrapolated to include the extra distance), HV1 was turned off. The electrode at the cathode from HV1 was removed from the buffer in R2. The ground electrode from a positive highvoltage power supply (HV2) was immersed in the buffer in R2, and the anode was placed in the 1 × TBE buffer in R3. Then, a positive voltage (9 kV) was applied between R2 and R3 for 40 to 50 s to inject negatively charged DNA fragments into the CGE capillary. A steel wire with its two ends immersed in the buffer in R1 and R2 should be used to equalize the potential of R1 and R2 during injection and subsequent CGE separation. After injection of the DNA ladder into C3, HV2 was turned off. The THM buffer solutions in capillaries C1 and C2, and in R1 and R2 were replaced by 1 × TBE buffer. Then, HV2 was turned on to apply 12 kV between R2 and R3 to start the separation of the DNA ladder in CGE. In the analysis of DNA fragments produced from the dye-labeled terminatorsequencing reaction, the major interference comes from the unincorporated dyelabeled terminators (d-ddNTPs) and the high concentration of salt. The d-ddNTPs will interfere with the detection of the dye-labeled DNA ladder (d-DNAs) in CGE, and seriously reduce the accuracy of base calling. The high concentration of salt will significantly reduce the amount of DNA injected electrokinetically into the CGE capillary (lower effective potential), and will also degrade the separation of the DNA ladder (perturbation of the separation buffer). In previous sample-cleanup methods, the separation of d-ddNTPs and d-DNAs was based on their solubility differences in organic solvent (e.g., ethanol precipitation) or size differences (e.g., SEC). In the new approach investigated here, the separation of d-ddNTPs and d-DNAs is attained on the basis of their mobility differences in CZE. In CZE, the electrophoretic mobility of a molecule is primarily determined by its charge-to-mass ratio (z/m). It is well known that DNA fragments of different sizes (greater than ∼20 bp) have almost equal electrophoretic mobilities (µele) in free solution electrophoresis due to their very similar z/m ratios.50,62,63 When a dye is attached to the DNA fragments, µele should decrease because the dye has much smaller z/m ratio than the DNA fragments. However, the decrease of µele should be very small for DNA fragments with more than 20 bp, i.e., all fragments larger than the primer, as the z/m ratio of the whole fragment is primarily determined by the nucleotides. So, various d-DNAs are expected to migrate close to each other in free-solution CZE. On the other hand, the attachment of rhodamine dye to the ddTTP reduces its z/m by about half from approximately –3/500 to –3/1000. Note that both ddTTP and d-ddTTP have net –3 charge in weakly basic solutions, and ddTTP and rhodamine dye have similar molecular weights (around 500). Additionally, the dddTTP will form a stable 1:1 complex with Mg2+ present in the reaction mixture,64,65 reducing its net charge from –3 to –1. Hence, the z/m for ddATP-Mg2+ complex is only about –1/1000. On the other hand, the z/m ratio of d-DNA20 is only slightly reduced by the attachment of dye and the presence of Mg2+, and is thus slightly lower than –1/500. Therefore, it can be expected that the µele of d-DNAs should be higher than that of the ddNTPs in basic solution, which forms the basis of their separation by CZE. In previous work on on-line injection of d-DNAs from SEC to CGE, injection was initiated when the top of the d-DNAs peak reached the center of the cross
50
Analytical Techniques in DNA Sequencing
junction.23 In the present system, however, it was observed that small amounts of d-ddNTPs would be injected together with the d-DNAs if the same protocol was utilized. Moreover, the reproducibility of the signal intensity in CGE was poor. This confirms that electro-osmotic flow is less reliable than pressure-driven flow. To circumvent this problem, voltage switching was performed after the d-DNAs peak entered C2 and reached a point about 1.5 cm beyond the center of the tee junction. This was to ensure that the d-DNAs were totally inside C2 despite the run-to-run variations in migration time. Since the electro-osmotic flow from C3 to C2 was largely suppressed by the PEO gel in C3, the d-DNAs moved faster than d-ddNTPs during injection. Therefore, it became easier to control the injection of d-DNAs while avoiding the injection of d-ddNTPs. The performance of the optimized integrated online system was investigated in actual DNA sequencing. In the electropherograms of M13mp18 recorded by using one-wavelength excitation and dual-wavelength detection, data in both channels show high signal-to-noise ratios, and adequate resolution for base calling from 5 to 460 bp with an accuracy of 97%. The majority of miscalled bases were from small G peaks following high T peaks. This implies that the on-column reaction generated more DNA fragments terminated by ddTTP as compared to off-line reaction, e.g., in Reference 52. Note that a minimal amount of dye was present around 20 bp, which, however, did not interfere with base calling. Related experiments indicated that the small amount of dye present in this region was not introduced during injection, but might be caused by diffusion of the concentrated dye labels as it initially passed the center of the µ-tee. Because the excess old-dye terminators comigrate with ~60 bp and ~110 bp DNA fragments in CGE, they will mask several base pairs around those regions in the sequencing separation and introduce errors in base calling. Also the high salt content of the reaction mixture makes electrokinetic injection to the CGE capillary extremely difficult. Proper purification of the cycle-sequencing product to eliminate these interferences must be incorporated into the online system. CZE separation is especially attractive because it does not require additional instrumental components such as a high-pressure pump. However, in bare fused-silica capillaries, because electro-osmotic flow (EOF) dominates the direction of migration, the dye terminators, which have smaller electrophoretic mobilities, migrate faster than the DNA fragments. The strong tailing of the terminator peaks, which is probably due to their strong hydrophobicity, makes the separation very difficult. Furthermore, the uncertainty in EOF due to variable surface conditions of the capillary inner wall makes the migration times in a capillary array very irreproducible.26 This makes multiplexed CZE purification, where very precise timing and very short injection time to the CGE capillary is required, almost impossible. We also use CZE with suppressed EOF to separate the dye terminators from the DNA fragments.66 Several separation systems were studied to optimize the online system. The most obvious idea would be to use the 1 × PCR buffer as the separation buffer (pH = 8.9), which is completely compatible with the cycle-sequencing reaction. Because of its high ionic strength, the cations would shield the deprotonated silanol groups on the inner wall of the capillary to suppress EOF. A very good separation was achieved (Figure 3.6a). The DNA fragments migrated as a narrow
Microscale Sample Preparation for DNA Sequencing and Genotyping
51
150 DNA Fragments
a 100
Dye-labeled ddNTPs
50 0 0
5
10
25
15
20
25
30
DNA Fragments b
20 Dye-labeled ddNTPs 15 5
10
15
20
25
30
35
60 DNA Fragments 40
Dye-labeled ddNTPs
c
20 0 0
5
10 15 Time (min)
20
FIGURE 3.6 CZE purification of cycle-sequencing product. (a) Bare fused-silica capillary, 1 × PCR buffer with 50 mM KCl. (b) PVA-coated capillary, 1 × PCR buffer with 4 mM KCl. (c) Bare fused-silica capillary, 1 × PCR buffer with 2 mM KCl, 0.3% 1,000,000 MW PVP.
band because of their similar mass-to-charge ratios. However, when high voltage is applied across the CZE capillary and the CGE capillary during electrokinetic injection, most of the voltage will drop along the CGE capillary. Thus, the field strength in the CZE capillary will be much smaller than that in the CGE capillary, which is just the opposite scenario as in electrostacking. Therefore, electrokinetic injection turned out to be very inefficient. One of the other choices would be using coated capillaries. Different coated capillaries, such as fluorocarbon (FC), polyethleneglycol (PEG), polyvinylalcohol (PVA), DB-WAX coated capillaries, were tested as the integrated reaction vessel and separation column. 1 × PCR buffer with low concentrations of KCl (pH = 8.9) was tested as the separation medium. The PVA-coated capillary proved to be the best choice in terms of suppressing EOF. Good separation from the dye terminators was achieved (Figure 3.6b), although the DNA fragments appeared as a broader band. Different concentrations of KCl were tested for the CZE separation and electrokinetic injection efficiency. From 2 to 4 mM KCl proved to be best separation condition as a trade-off between DNA bandwidth and online injection efficiency, which was confirmed by good DNA signals and sequencing separation with base
52
Analytical Techniques in DNA Sequencing
calling up to 500 bases. No dye-terminator interference was observed. However, there are two inevitable problems inherent to coated capillaries. One is the cost in a multiplexed system and the other is degradation of the coating. After about 20 reaction and CZE separations, a noticeable decrease in the reaction efficiency was observed. Also, EOF gradually increased. Attempts to regenerate the capillary by washing it with methanol and D.I. water were not successful. In the previous studies, we demonstrated that EOF of bare fused-silica capillary could be substantially suppressed by the dynamic coating of PVP solution due to the strong hydrogen bonding between the hydrophilic carbonyl group of PVP and the residual hydroxyl group on the capillary wall.67 Compatibility of the PVP coating with the cycle-sequencing reaction was therefore studied by flushing the long capillary loop with 2% PVP followed by placing the capillary in the commercial air thermocycler for offline cycle-sequencing reaction. After reaction, about ~2 µl of reaction product was collected and purified by spin column. CGE separation of the purified DNA product showed similar signal strength as that without PVP coating, which confirmed that PVP did no harm to the reaction. During CZE separation, PVP was added to the separation buffer to achieve more even coating. Different concentrations of PVP were investigated for efficiency for suppressing EOF and for separation. At pH 8.9, 1.0% PVP was required to suppress EOF consistently. However, because the entanglement limit of 1,000,000 MW PVP is about 0.7%, at such a high PVP concentration the DNA fragment peak was substantially broadened by the sieving effect. An alternative approach was to lower the pH of the separation buffer. It was found that at pH 8.2, only 0.3% PVP was needed to suppress EOF. Different sized DNA fragments comigrated as a narrow band with half peak width of ~1.5 min (Figure 3.6c). More important was that there was no compromise in the reaction efficiency in such a low pH buffer. The surfactant, Triton X-100, was taken out from the buffer to avoid bubble formation around the microtee connection during CZE separation. Very reproducible separation (±2% in migration times) was achieved with PVP dynamic coating. The bare fused-capillary could be reused again and again by simply flushing the capillary with the separation buffer between runs. For over 1 month of experiments, more than 40 reactions and separations were performed on the same capillary. No decay in the online reaction efficiency was observed and the DNA fragments showed very reproducible migration times.
HIGH-THROUGHPUT PCR ANALYSIS
OF
CLINICAL SAMPLES
For laser-induced fluorescence (LIF) detection in CE, as few as 105 molecules are typically detectable in most laboratories and with state-of-the-art equipment. Even single-molecule detection is attainable.68 However, the DNA fragments need to be fluorescently labeled, which involves expensive reagents and increases the concern for waste disposal because of the toxic nature of the reagents. Instrumentation for LIF detection in CAE is also costly. Here,69 we show a new PCR sample preparation protocol starting directly from cheek cells or from blood that can be used in multiplexed CE with UV detection. No purification of the PCR products was necessary by simply applying base stacking.18 The basis for this approach is that for every
Microscale Sample Preparation for DNA Sequencing and Genotyping
53
PCR reaction, the concentration of the product will eventually reach a plateau that approaches the µM range.3 This is sufficient for UV detection because each DNA fragment has more than 100 absorbing units. The complete integration of sample preparation and detection provides a very cost effective scheme to be used in the clinical and forensic laboratories for PCR-based DNA analysis. In the approach, 5-ml blood samples were collected from volunteers into the containers, which have 0.057 ml, 0.34 M K3EDTA as a preservative. The final concentration of EDTA in blood is 3.9 µM, which has no effect on the PCR reaction. The blood sample was stored in a refrigerator until use to prevent hemolysis. For analysis, a 6- µl blood sample was mixed thoroughly with 90 µl formamide. The mixture was incubated at 95°C for 10 min before PCR reaction. Then, 3 µl of the above sample was used in a 20- µl reaction mixture to amplify a 110-bp fragment of the β-globin gene with specific primers. The 20- µl reaction mixture had the following final composition: standard 1 × PCR buffer from Promega, 50 mM KCl and 10 mM Tris/HCl, pH 8.3; 3.5 mM MgCl2; 250 µM each of dNTP, 1 µM of each primer; 0.25 µg/µl BSA; 0.5 µg/µl T4 gene 32 protein; 0.25 unit/µl Tth enzyme. The reaction was performed in a 360 µm o.d., 250 µm i.d. capillary using a Rapid Cycler. The PCR protocol is listed in Table 3.1. The fully automated, integrated online setup and operation are similar to what we used before.25 Briefly, PCR solution was aspirated by a syringe pump to the reaction capillary and sealed by freeze–thaw valves. After reaction, the reaction mixture was online-transferred to the injection cross and injected at 50 V/cm for 6 min. Then injection of 0.1 M NaOH followed to ensure the stacking of the DNA sample. Finally, 1 × TE buffer was employed to run the electrophoresis. A 115-bp fragment from the gag region of the HIV-1 DNA was amplified using the HIV test kit from Perkin-Elmer. The individual components were added according to the manufacturer’s suggestion, except that 0.25 µg/µl BSA was added to prevent the adsorption of the Taq enzyme on the capillary. The protocol is 94°C for 2 min followed by 40 cycles of denaturation at 95°C for 15 s, annealing and extension at 60°C for 1 min. The annealing and extension temperatures were the same for this protocol. Buccal epithelial cells were collected by twirling a sterile swab on the inner cheek for 30 s. The swab was immersed into 400 µl of formamide in a microfuge tube. TABLE 3.1 PCR Protocol Using Blood Directly as the Template Operation
Temp. (°C)
Time (s)
Cycle No.
Incubation Denature Anneal Extension Denature Anneal Extension Hold
85 80 45 60 80 45 60 60
120 60 60 60 15 30 60 600
1 3
40
1
54
Analytical Techniques in DNA Sequencing
The tube with the swab was heated at 95°C for 15 min and the swab was removed. A 20- µl reaction consists of 3 µl of the buccal cell DNA solution, 1 µM of each of the primers, 200 µM of dNTP; 3 mM of MgCl2, 2.5 units of Taq DNA polymerase and 1 × Tris/HCl buffer with 0.25 µg/µl BSA. The cheek cell can also be transferred into the reaction mixture directly using a plastic toothpick, in which case lysing of the cheek cell was achieved by the incubation step of the PCR reaction. Cheek cells from five individuals were tested and PCR reactions were performed in a PerkinElmer GeneAmp PCR system 2400. The temperature protocol was incubation at 80°C for 2 min, followed by 35 cycles of denaturation at 80°C for 20 s, annealing at 53°C for 1 min and extension at 60°C for 1 min. When using cheek cells directly in the PCR reaction mixture, the incubation step is 7 min at 80°C. The concentration of DNA after reaction generally approaches µM and should be sufficient for UV detection. However, for CE with UV detection, excess salts in the sample matrix interfere with effective sample injection.70,71 A possible solution is to use a size-exclusion column to purify the sample and online inject the sample into the capillary. As we already demonstrated in online DNA sequencing, samples in low-ionic-strength buffers can be injected up to 3 min at the running voltage without sacrificing the resolution.46 However, a simpler way exists for the analysis of crude PCR mixtures. There are several stacking methods that can be used to overcome problems associated with inefficient sample utilization.72,73 Swerdlow18 described a base-stacking method for DNA sequencing from unpurified products. Briefly, the hydroxide ions neutralize the Tris ions to generate a zone of low conductivity. On-column concentration of the DNA fragments was achieved by electrokinetic injection of hydroxide ions. A low-conductivity zone was produced by the neutralization reaction between OH– ions with the cationic buffer. The higher electric field in the zone causes DNA to be concentrated. We use this stacking method to inject PCR reaction mixtures which contain 50 mM KCl, although the KCl is not always necessary.73 The signal is higher in the case of base stacking than for ordinary injection. We find there is no interference from dNTP because they move faster than the PCR products. To achieve base stacking in these small volumes, the 0.1 M NaOH vials should be kept closed after stacking. Otherwise CO2 will neutralize some OH− and ruin the stacking. In genetic analysis, it is always desirable to amplify DNA directly from clinical materials to avoid sample manipulation. Although blood is a very complicated mixture and using blood is prone to contamination, the amount of DNA in blood is relatively constant: 1 µl of blood generally contains 4.1 to 10.3 × 103 white blood cells. It was found that the major problem for PCR direct from blood was the inability of the DNA polymerase to access the target DNA.19 The solution is to find conditions that will release DNA from cells in a form suitable for PCR while preserving the activity of Taq DNA polymerase. We tried to use water to lyse the cells, but PCR was not successful. Based on the observed cell debris, the DNA most likely was trapped by coprecipitation with proteins. So, FoLT (formamide low temperature) PCR, which was demonstrated before for slab-gel electrophoresis, was used here for UV-CE analysis.20 For cheek cells, the matrix is cleaner than blood. Cheek cells lysed in water have been used in PCR. The common method is to use 15 ml NaCl solution to wash the mouth. This procedure produces a yield of total genomic DNA of about 2 to 5 µg
Microscale Sample Preparation for DNA Sequencing and Genotyping
55
and is sufficient for many PCR reactions. One inconvenient feature is that centrifugation is needed to precipitate the cells. The use of cytology brushes and swabs as a more efficient means to cell collection/DNA extraction has also been demonstrated and validated in several research groups.21,22 This method is easily performed in a 96-well format and is compatible with high-throughput testing. In previous reports, cheek cells were lysed in 0.1 M NaOH and later neutralized with Tris/HCl. Here, we show that we can avoid the neutralization step by heating in formamide to lyse the cells either before or during the PCR reaction. Compared with normal PCR starting from pure DNA, PCR from cheek cells or from blood gave good results. In Figure 3.7, PCR amplification of β-globin directly from blood and HIV analysis were demonstrated. First, 1 × TE buffer was injected into capillary 13 and was used for base-line subtraction to cancel out the flicker noise from the mercury lamp, as reported before.74 In all, 12 different samples using cheek cells from five individuals with two different primer sets were amplified in a commercial thermal cycler and analyzed by the array. The electropherograms from two capillaries show negative PCR results, for which no cheek cell was added but formamide and all other reagents for PCR reaction were present. This shows the lack of DNA contamination in the system. A longer-term study with actual clinical samples will be necessary to verify that memory effects are absent from repeated use of the system.
-5800 A β-globin 125 bp
-6000
-6200
HIV
35bp0
B
25
30
-6400 15
20
35
Time (min)
FIGURE 3.7 Online PCR analysis of (A) a 110-bp fragment of β-globin gene amplified from blood and spiked with 25-bp DNA ladder; (B) a 115-bp fragment of HIV gag DNA spiked with 50-bp DNA ladder.
56
Analytical Techniques in DNA Sequencing
Amplification from mitochondrial DNA generates more DNA products because hundreds of copies of mitochondrial DNA are present in each human cell.75 To increase the confidence level for identification, the PCR products were coinjected with a 100-bp ladder for some of the capillaries. The electropherograms show the two products, which are the 241-bp fragment for the cyto primer and the 256-bp fragment for the M69 primer. The capillary array was flushed with water between runs and did not show degradation over months. Because the sample preparation step and sample injection step can be easily integrated and automated by this protocol, this has the potential of becoming a costefficient and high-throughput approach to perform genetic analysis or disease diagnosis at a low cost. For example, one can envision equipping a doctor’s office with a CAE instrument and a thermal cycler. Test kits in 96-well microtiter plates can be factory-prepared for such analyses. Each vial in the microtiter plate would contain the premix solution as specified here plus a distinct primer pair. PCR analysis can thus be performed 96 at a time for multiple genetic regions or for multiple patients directly from cheek cell swabs or microliter volumes of blood. No solution preparation or sample preparation will be required at the test site. Such a system will allow doctors and nurses, as opposed to highly skilled laboratory technicians, to gain immediate access to genetic dispositions relevant to disease in 1 or 2 h. The protocol described here is applicable to both fluorescence-based and absorptionbased capillary array instruments, although the latter is less expensive to operate (no lasers and no dyes). Because such instruments are already commercially available, practical applications should be imminent.
ACKNOWLEDGMENT The authors thank the many coworkers whose work laid the foundation of this chapter. The Ames Laboratory is operated for the U.S. Department of Energy by Iowa State University under Contract No. W-7405-Eng-82. This work was supported by the Director of Science, the Office of Biological and Environmental Research, and by the National Institutes of Health.
REFERENCES 1. E Pennesi. Human genome: Finally, the book of life and instructions for navigating it. Science 288:2304–2307, 2000. 2. F Collins, A Patrinos, E Jordan, A Chakravarti, R Gesteland, L Walters. New goals for the U.S. human genome project: 1998–2003. Science 282:682–689, 1998. 3. W Bloch. A biochemical perspective of the polymerase chain reaction. Biochemistry 30:2735–2747, 1991. 4. Y Hu, JL Glass, AE Griffith. Observation and simulation of electrohydrodynamic instabilities in aqueous colloidal suspensions. J Chem Phys 100:4674– 4682, 1994. 5. K Ueno, ES Yeung. Simultaneous monitoring of DNA fragments separated by capillary electrophoresis in a multiplexed array of 100 capillaries. Anal Chem 66:1424–1431, 1994.
Microscale Sample Preparation for DNA Sequencing and Genotyping
57
6. XC Huang, MA Quesada, RA Mathies. DNA sequencing using capillary array electrophoresis. Anal Chem 64:2149–2154, 1992. 7. NJ Dovichi, H Swerdlow, JZ Zhang, DY Chen, HR Harke. Three DNA sequencing methods using capillary gel electrophoresis and laser-induced fluorescence. Anal Chem 63:2835–2841, 1991. 8. H Kambara, S Takahashi. Multiple-sheathflow capillary array DNA analyser. Nature 361:565–566, 1993. 9. C Kilger, M Krings, H Poinar, S Pääbo. “Colony sequencing”: Direct sequencing of plasmid DNA from bacterial sources. BioTechniques 22:412–418, 1997. 10. Q Chen, C Neville, A MacKenzie, RG Korneluk. Automated DNA sequencing requiring no DNA template purification. BioTechniques 21:453–457, 1996. 11. MA Marra, TA Kucaba, LW Hillier, RH Waterstion. High-throughput plasmid DNA purification for 3 cents per sample. Nucleic Acids Res 27:e37, i–vi, 1999. 12. AS Cohen, DR Najarian, BL Karger. Separation and analysis of DNA sequence reaction products by capillary gel electrophoresis. J Chromatogr 516:49–60, 1990. 13. O Salas-Solano, E Carrilho, L Kotler, AW Miller, W Goetzinger, Z Sosic, BL Karger. Routine DNA sequencing of 1000 bases in less than one hour by capillary electrophoresis with replaceable lineary polyacrylamide solutions. Anal Chem 70:3996–4003, 1998. 14. W Wei, ES Yeung. Improvements in DNA sequencing by capillary electrophoresis at elevated temperature using polyethylene oxide) as a sieving matrix. J Chromatogr A 745:221–230, 2000. 15. MC Ruiz-Martinez, O Salas-Solano, E Carrilho, L Kotler, BL Karger. A sample purification method for rugged and high-performance DNA sequencing by capillary electrophoresis using replaceable polymer solutions. A. Development of the cleanup protocol. Anal Chem 70:1516–1527, 1998. 16. O Salas-Solano, MC Ruiz-Martinez, E Carrilho, L Kotler, BL Karger. A sample purification method for rugged and high-performance DNA sequencing by capillary electrophoresis using replaceable polymer solutions. B. Quantitative determination of the role of sample matrix components on sequencing analysis. Anal Chem 70:1528–1535, 1998. 17. H Zhou, AW Miller, Z Sosic, B Buchholz, AE Barron, L Kotler, BL Karger. DNA sequencing up to 1300 bases in two hours by capillary electrophoresis with mixed replaceable linear polyacrylamide solutions. Anal Chem 72:1045–1052, 2000. 18. Y Xiong, SR Park, H Swerdlow. Base stacking: pH-mediated on-column sample concentration for capillary DNA sequencing. Anal Chem 70:3605–3611, 1998. 19. M Panaccio, AM Lew. PCR based diagnosis in the presence of 8% (v/v) blood. Nucleic Acids Res 19:1151, 1991. 20. M Panaccio, AM Lew. Direct PCR from whole blood using formamide and low temperatures. In: HG Griffin, AM Griffin, eds. PCR Technology: Current Innovations. New York: CRC Press, 1994, 151–157. 21. B Richards, J Skoletsky, AP Shuber, R Balfour, RC Stern, HL Dorkin, RB Parad, D Witt, KW Klinger. Multiplex PCR amplification from the CFTR gene using DNA prepared from buccal brushes/swabs. Hum Mol Genet 2:159–163, 1993. 22. Y Liu, J Bai, Y Zhu, X Liang, D Siemieniak, PJ Venta, DM Lubman. Rapid screening of genetic polymorphisms using buccal cell DNA with detection by matrix-assisted laser desorption/ionization mass spectrometry. Rapid Commun Mass Spectrometry 9:735–743, 1995. 23. H Tan, ES Yeung. Integrated on-line system for DNA sequencing by capillary electrophoresis: From template to called bases. Anal Chem 69:664–674, 1997.
58
Analytical Techniques in DNA Sequencing 24. H Tan, ES Yeung. Automation and integration of multiplexed on-line sample preparation with capillary electrophoresis for high-throughput DNA sequencing. Anal Chem 70:4044–4053, 1998. 25. N Zhang, H Tan, ES Yeung. Automated and integrated system for high-throughput DNA genotyping directly from blood. Anal Chem 71:1138–1145, 1999. 26. H Swerdlow, BJ Jones, CT Wittwer. Fully-automated PCR and DNA sequencing: Reaction and analysis in a fluidic capillary instrument. Anal Chem 69:848–855, 1997. 27. SA Soper, DC Williams, Y Xu, SJ Lassiter, Y Zhang, SM Ford, RC Bruch. Sanger DNA sequencing reactions performed in a solid-phase nano-reactor directly coupled to capillary gel electrophoresis. Anal Chem 70:4036–4043, 1998. 28. MA Burns, BN Johnson, SN Brahmasandra, K Handique, J Webster, M Krishnan, TS Sammarco, PM Man, D Jones, D Heldsinger, CH Mastrangelo, DT Burke. An integrated nanoliter DNA analysis device. Science 282:484–487, 1998. 29. E Litborn, A Emmer, J Roeraade. Chip-based nanovials for tryptic digest and capillary electrophoresis. Anal Chim Acta 401:11–19, 1999. 30. E Litborn, A Emmer, J Roeraade. Parallel reactions in open chip-based nanovials with continuous compensation for solvent evaporation. Electrophoresis 21:91–99, 2000. 31. SA Soper, SM Ford, Y Xu, S Qi, S McWhorter, S Lassiter, D Patterson, RC Bruch. Nanoliter-scale sample preparation methods directly coupled to polymethylmethacrylate-based microchips and gel-filled capillaries for the analysis of oligonucleotides. J Chromatogr A 853:107–120, 1999. 32. J Khandurina, TE McKnight, SC Jacobson, LC Waters, RS Foote, JM Ramsey. Integrated system for rapid PCR-based DNA analysis in microfluidic devices. Anal Chem 72:2995–3000, 2000. 33. Q Li, T Kane, C Liu, H Zhao, R Fields, J Kernan. Fully automated DNA sequencing with a commercial 96-capillary array instrument. HPCE ’99, Palm Springs, CA, 1999, Abstract 32. 34. T Anazawa, S Takahashi, H Kambara. A capillary-array electrophoresis system using side-entry on-column laser irradiation combined with glass rod lenses. Electrophoresis 20:539–546, 1999. 35. M Quesada, S Zhang. Multiple capillary DNA sequencer that uses fiber-optic illumination and detection. Electrophoresis 17:1841–1851, 1996. 36. M Quesada, H Dhadwal, D Fisk, F Studier. Multi-capillary optical wavelengths for DNA sequencing. Electrophoresis 19:1415–1427, 1998. 37. NJ Dovichi. DNA sequencing by capillary electrophoresis. Electrophoresis 18:2393– 2399, 1997. 38. JR Scherer, I Kheterpal, A Radhakrishnan, WW Ja, RA Mathies. Ultra-high throughput rotary capillary array electrophoresis scanner for fluorescent DNA sequencing and analysis. Electrophoresis 20:1508–1517, 1999. 39. I Kheterpal, RA Mathies. Capillary array electrophoresis DNA sequencing. Anal Chem 71:31A–37A, 1999. 40. PC Simpson, D Roach, AT Woolley, T Thorsen, R Johnston, GF Sensabaugh, RA Mathies. High-throughput genetic analysis using microfabricated 96-sample capillary array electrophoresis microplates. Proc Natl Acad Sci USA 95:2256–2261, 1998. 41. I Medintz, W Wong, G Sensabaugh, RA Mathies. High speed single nucleotide polymorphism typing of a hereditary haemochromatosis mutation with capillary array electrophoresis microplates. Electrophoresis 21:2352–2358, 2000. 42. S Liu, Y Shi, WW Ja, RA Mathies. Optimization of high-speed DNA sequencing on microfabricated capillary electrophoresis channels. Anal Chem 71:566–573, 1999.
Microscale Sample Preparation for DNA Sequencing and Genotyping
59
43. S Liu, H Ren, Q Gao, D Roach, R Loder, TM Armstrong, Q Mao, L Blaga, D Barker, S Jovanovich. Automated parallel DNA sequencing on multiple channel microchips. Proc Natl Acad Sci USA 97:5369–5374, 2000. 44. H Drossman, JA Luckey, AJ Kostichka, J D’Cunha, LM Smith. High speed separations of DNA sequencing reactions by capillary electrophoresis. Anal Chem 62:900–903, 1990. 45. JC Venter, HO Smith, L Hood. A new strategy for genome sequencing. Nature 381:364–366, 1996. 46. Y Zhang, H Tan, ES Yeung. Multiplexed and automated DNA sequencing directly from single bacterial colonies. Anal Chem 71:5018–5025, 1999. 47. X Xu, ES Yeung. Direct measurement of single-molecule diffusion and photodecomposition in free solution. Science 276:1106–1109, 1997. 48. O Kalinina, I Lebedeva, J Brown, J Silver. Nanoliter scale PCR with TaqMan detection. Nucleic Acids Res 25:1999–2004, 1997. 49. LA Kolmodin, JF Williams. PCR Cloning Protocols. Totowa, NJ: Humana Press, 1997, 3–15. 50. LG Lee, CR Connell, SL Woo, RD Cheng, BF McArdle, CW Fuller, ND Halloran, RK Wilson. DNA sequencing with dye-labeled terminators and T7 DNA polymerase: Effect of dNTPs on incorporation of dye-terminators and probability analysis of termination fragments. Nucleic Acids Res 20:2471–2483, 1992. 51. JP Landers, RP Oda, TC Spelsberg, JA Nolan, KJ Ulfelder. Capillary electrophoresis: A powerful microanalytical technique for biologically active molecules. BioTechniques 14:98–111, 1993. 52. Q Li, ES Yeung. Simple two-color base-calling schemes for DNA sequencing based on standard four-label Sanger chemistry. Appl Spectrosc 49:1528–1533, 1995. 53. DR Meldrum. A biomechatronic fluid-sample-handling system for DNA processing. IEEE/ASME Trans Mechatronics 2:99–109, 1997. 54. DR Meldrum, HT Evensen, WH Pence, SE Moody, DL Cunningham, PJ Wiktor. ACAPELLA-1K, a capillary-based submicroliter automated fluid handling system for genome analysis. Genome Res 10:95–104, 2000. 55. MU Kopp, AJ deMello, A Manz. Chemical amplification: Continuous-flow PCR on a chip. Science 280:1046–1048, 1998. 56. LC Waters, SC Jacobson, N Kroutchinina, J Khandurina, R Foote, JM Ramsey. Multiple sample PCR amplification and electrophoretic analysis on a microchip. Anal Chem 70:5172–5176, 1998. 57. HT Evenson, DR Meldrum, DL Cunningham. Automated fluid mixing in glass capillaries. Rev Sci Instr 69:519–526, 1998. 58. H-M Pang, ES Yeung. Automated one-step DNA sequencing based on nanoliter reaction volumes and capillary electrophoresis. Nucleic Acids Res 28:e73, i–viii, 2000. 59. MC Raja, D Zevin-Sonkin, J Shwartzburd, TA Rozovskaya, IA Sobolev, O Chertkov, V Ramanathan, L Lvovsky, LE Ulanovsky. DNA sequencing using differential extension with nucleotide subsets (DENS). Nucleic Acids Res 25:800–805, 1997. 60. EN Fung, H-M Pang, ES Yeung. Fast DNA separations by using poly(ethylene oxide) in non-denaturing medium with temperature programming. J Chromatogr A 806:157–164, 1998. 61. Y He, H-M Pang, ES Yeung. Integrated electroosmotically-driven on-line sample purification system for nanoliter DNA sequencing by capillary electrophoresis. J Chromatogr A 894:179–190, 2000.
60
Analytical Techniques in DNA Sequencing 62. DM Goodall, SJ Williams, DK Lloyd. Quantitative aspects of capillary electrophoresis. TrAC 10:272–279, 1991. 63. D Rickwood, BD Hames, Eds. Gel Electrophoresis of Nucleic Acids: A Practical Approach. Washington, DC: IRL Press, 1983. 64. H Sigel, Ed. Metal Ions in Biological Systems. New York: Marcel Dekker, 1979, Vol. 9. 65. F Sanger, S Nicklen, AR Coulson. DNA sequencing with chain-terminating inhibitors. Proc Natl Acad Sci USA 74:5463–5467, 1977. 66. G Xue, H-M Pang, ES Yeung. On-line nanoliter cycle sequencing reaction with capillary zone electrophoresis purification for DNA sequencing. J Chromatogr A 914:245–256, 2001. 67. Q Gao, ES Yeung. A matrix for DNA separation: Genotyping and sequencing using poly(vinylpyrrolidone) solution in uncoated capillaries. Anal Chem 70:1382–1388, 1998. 68. Y-H Lee, RG Maus, BW Smith, JD Winefordner. Laser-induced fluorescence detection of a single molecule in a capillary. Anal Chem 66:4142–4149, 1994. 69. Y Zhang, Y He, ES Yeung. High throughput PCR analysis of clinical samples by capillary electrophoresis with UV detection. Electrophoresis 22:2296, 2001. 70. XC Huang, SG Stuart, PF Bente, TM Brennan. Capillary gel electrophoresis of singlestranded DNA fragments with UV detection. J Chromatogr A 600:289–295, 1992. 71. PE Williams, MA Marino, SA Del Rio, LA Turni, JM Devaney. Analysis of DNA restriction fragments and polymerase chain reaction products by capillary electrophoresis. J Chromatogr A 680:525–540, 1994. 72. R-L Chien, DS Burgi. On-column sample concentration using field amplification in CZE. Anal Chem 64:489A–496A, 1992. 73. JP Quirino, S Terabe. Exceeding 5000-fold concentration of dilute analytes in micellar electrokinetic chromatography. Science 282:465–468, 1998. 74. X Gong, ES Yeung. An absorption detection approach for multiplexed capillary electrophoresis using a linear photodiode array. Anal Chem 71:4989–4996, 1999. 75. JS Hanekamp, WG Thilly, MA Chaudhry. Screening for human mitochondrial DNA polymorphisms with denaturing gradient gel electrophoresis. Hum Genet 98:243–245, 1996.
4
Microfabricated DNA Sequencing Devices Brian M. Paegel, Robert G. Blazej, and Richard A. Mathies
CONTENTS Introduction..............................................................................................................61 DNA Sequencing Bioprocessors .............................................................................64 Single-Channel Beginnings .........................................................................64 Capillary Array Electrophoresis Microchips...............................................65 Applications of the µCAE Bioprocessor ....................................................71 Prospects: Bioprocessors with Integrated Chemistries ...........................................74 Integrated DNA Amplification ....................................................................74 Integrated DNA Purification........................................................................75 Acknowledgments....................................................................................................80 References................................................................................................................80
INTRODUCTION The evolution of analytical technology is crucial for the advancement of any scientific discipline, but perhaps never in history has this fact been more poignantly illustrated than in the rapid and efficient completion of the human genome sequence.1 Over the course of 10 years, the costs, complexity, and analysis time were systematically reduced and the sample throughput increased through the development of fluorescence-based methods,2,3 engineered polymerases,4,5 efficient fluorescent dye-labeling constructs,6 and high-throughput capillary array electrophoresis (CAE) instrumentation.7–9 Now that the Human Genome Project is in its finishing stage, our thirst for genomic knowledge is only intensifying, with genome sequencing projects targeting myriad model and industrially important organisms,10,11 as well as the emergence of interspecies studies of genetic variation.12 The current CAE paradigm was instrumental in providing the sample throughput required to tackle the massive, repeat-rich human genome, but the dependence of this format on large, expensive robotic systems that are incapable of manipulating submicroliter volumes make it an interim solution to a much larger analytical challenge: How do we exploit the nanoliter sampling capabilities of capillary electrophoresis (CE) analysis, eliminate robotics and difficultto-automate sample preparation steps, increase data quality and throughput, and further reduce costs? 61
62
Analytical Techniques in DNA Sequencing
Bond
Spin on Photoresist
Mask and Expose
Glass Etch
Develop
FIGURE 4.1 Schematic of the microfabrication process for making CE devices. A blank glass wafer is spin-coated with PR and the desired pattern is transferred to the PR film by exposure to UV through a photomask. The PR is developed and the exposed glass regions are etched in HF to produce trenches 20 to 50 µm deep. After etching, the remaining PR is stripped, the etched wafer is drilled through at reservoir locations, and thermally bonded to a blank glass wafer to form the capillary channels.
In 1992, CE analysis in planar silicon and glass chips was introduced by Manz and Harrison.13,14 The planar glass wafer fabrication method is schematically outlined in Figure 4.1. A blank glass wafer is spin-coated with a photoreactive resin called photoresist (PR). The desired pattern of microcapillary channels described on a master photomask is then transferred to the PR by contact exposure with ultraviolet (UV) light. Exposed regions of PR are washed away in a developer bath, and the substrate is immersed in HF to etch the glass isotropically. Microchannels for DNA analysis range from 10 to 50 µm deep, and from 30 to 200 µm wide. The remaining photoresist is stripped away, holes are drilled through the etched substrate at the locations of access reservoirs, and the channels are completed by thermal compression bonding with a blank glass substrate of similar size. The entire fabrication procedure is compatible with the microelectronics industry very large scale integration (VLSI) processing techniques and instrumentation.15 The key advantage of planar CE chip technology lies in the photo-patterning step. Modern contact printing permits the control of patterns to the UV diffraction limit, facilitating the micron-scale control of such features as capillary geometry, reactor shape and placement, and array interconnectivity. Alternative conventional capillary systems rely on cumbersome and unreliable physical joints to connect sections of capillaries and are geometrically confined to the cross section of a drawn capillary.16 Photolithography permits monolithic construction of massively parallel fluidic networks and micron-scale control of local channel geometry. The quintessential demonstration of these advantages is the cross-injector, a ubiquitous feature of CE microchips. In 1993, Harrison17 showed that an intersection of channels used as an injector allows the formation of extremely narrow sample plugs, making possible the separation of complex mixtures in a fraction of the column length required in conventional capillary systems. This concept is diagrammed in Figure 4.2.
Microfabricated DNA Sequencing Devices
Injection
63
Waste
Cathode
Anode Sample
Separation
Waste
Cathode
Anode Sample
DNA
GEL
FIGURE 4.2 Schematic of the cross-injection process. The sample reservoir is filled with DNA solution and the remaining reservoirs and channels are filled with gel buffer. During injection, sample is electrophoresed to the waste, thus filling the intersection of channels with sample. The anode and cathode reservoirs are poised at a slightly negative potential such that the sample is confined to the intersection (top). During separation, the sample contained in the intersection is driven to the high-voltage anode, while a positive potential is applied to the sample and waste reservoirs to avoid bleeding (bottom).
A cross-injector is an intersection of channels addressed by four reservoirs, typically labeled sample, waste, cathode, and anode. The running buffer is introduced through the anode, filling the entire system. The sample reservoir is filled with the analyte mixture and the rest are filled with the run buffer. A negatively charged analyte, such as DNA, is driven through the intersection by applying a positive potential at the waste reservoir while grounding the sample reservoir during “injection.” Switching to “separation” mode entails applying a large positive potential to the anode reservoir while grounding the cathode. Excess analyte in the sample and waste arms of the intersection is cleared by applying a small, positive potential to the sample and waste reservoirs. This process, called back-biasing, ensures that no analyte will leak or bleed from the reservoirs onto the separation column during the run. Processes for additional control of analyte flow during injection were refined by Jacobson et al.18 For example, the initial plug size can be further reduced through the application of slightly negative potentials at the anode and cathode, thus “pinching” the analyte stream and confining it to less than the volume defined by the intersection. This mode of injection allowed separations of dye-labeled amino acids in ~2 cm of column in less than 10 s.17 The implications of these early amino acid analysis experiments were profound because analysis times were reduced by more than an order of magnitude and the
64
Analytical Techniques in DNA Sequencing
possibilities for controlling channel density, interconnectivity, and geometry were seemingly limitless. This original work nucleated a variety of experiments exploring simple online labeling,19 characterizing electroosmotic pumping and valving,20 and porting classical CE applications such as electrochromatography to the microchip CE platform.21 The most dramatic reductions in analysis time, however, would come in the separation of DNA. In 1994, Woolley and Mathies22 reported separations of restriction enzyme-digested DNA using only a 3.5-cm-long channel, requiring less than 120 s for completion. The DNA separation experiment amplified the major advantage of miniaturized and integrated injection microfluidics: a small initial plug length requires less column length and therefore less time to achieve separation. With a comparable separation length and time to the original amino acid analysis device, separations of DNA are limited solely by the length of the initially injected plug because the diffusion coefficient of DNA in a gel is much lower than that of small molecules in free solution. Therefore, the demanding DNA sequencing separation requiring high-efficiency, single-base resolution is also an ideal candidate application for microchip CE.
DNA SEQUENCING BIOPROCESSORS SINGLE-CHANNEL BEGINNINGS The first sequencing results from a microfluidic CE device were described by Woolley and Mathies in 1995.23 In these seminal experiments, a cross-shaped channel was filled with acrylamide (9% T) and polymerized in situ. With an effective separation distance of 3.5 cm, ~200 bases (≥97% accuracy) were sequenced in 10 min. These results were not wholly unexpected in the context of previous DNA fragment sizing separations,22,24 but they strikingly presented the potential of the microchip CE paradigm. However, the work did leave open some very important questions. For example, the use of in situ polymerization of high-percentage linear polyacrylamide (LPA) made device reuse impossible because the gel matrix was too viscous to be removed from the channels. Furthermore, 200-base read lengths were relatively low compared to concurrently evolving CAE instrumentation. A solution to these issues was to be found in the replaceable, low-viscosity, large-chain LPA25 and longer effective length channels. Research focused on implementing replaceable polymers for DNA sequencing has advanced with the goal of allowing device reuse and increasing the read length through extended channel lengths. Schmalzing and coworkers26 reported single-color sequencing with an effective separation distance of 11.5 cm, generating 400 bases in 20 min, while the Liu and coworkers,27 utilizing the replaceable LPA formulation and optimized energy transfer (ET) primer cycle sequencing chemistry,6 generated 500 bases of fourcolor sequence (≥99% accuracy) in 20 min on a chip with an effective separation distance of only 7 cm. Early work with production sequencing samples indicated that the microchip paradigm could yield comparable, if not superior, results to commercially available CAE systems for “real-world” samples.28 Further optimization of sequencing on 11.5-cm-long channels was achieved by implementing a mixed molecular weight blend of emulsion-polymerized LPAs,29 resulting in 580-base read lengths
Microfabricated DNA Sequencing Devices
65
(≥98.5% accuracy) in 18 min.30 Paralleling this work, sequencing was also presented on a 40-cm-long channel that produced an average of 800 bases in 80 min. However, in this format, the analysis time was close to that required by conventional CAE sequencers.31 From these four collected studies, we may conclude that enhanced DNA sequencing in microfluidic devices requires a combination of superior sequencing chemistry, optimized polymer matrix, and extended separation distance, all of which play a pivotal role in determining a system’s performance.
CAPILLARY ARRAY ELECTROPHORESIS MICROCHIPS The single-channel experiments laid the groundwork for the development of microfabricated DNA sequencing bioprocessors: massively parallel arrays of sequencing channels. Microfabricated devices, in addition to providing reductions in analysis time, also offer the unique advantage of monolithic array construction. Dense arrays of precisely arranged channels are fabricated simply by increasing the complexity of the master photomask. An elegant demonstration of this principle may be found in the rapid scale-up of array complexity and density from 12, 48, 96, and finally to 384 lanes over a 5-year period.32–36 These devices, consisting of short channel lengths, showcased the benefits of microfabrication in constructing intricate and high-density arrays coupled to novel, compact injection microfluidics for genotyping, but were incompatible with the requirements of a successful sequencer device. The first prototype microfabricated CAE (µCAE) DNA sequencing array of 16 lanes was presented by Liu et al.37 The schematic for the device is presented in Figure 4.3A. The 16 lanes (effective separation distance of 7 cm) are fanned out on a 100-mm-diameter glass wafer, each lane containing an individual cross-injector with three reservoirs. The lanes converge on the detection area at the high-voltage bottom end of the device, which is scanned by a galvanometer-based rectilinear scanner. However, this channel design does not utilize the wafer surface area effectively and requires distance compensation at the anode end to equalize the electric field in all channels. Nonetheless, the array was an excellent preview of the throughput increases possible for µCAE, generating an average of 457 bases called to ≥99% accuracy across all lanes (effective separation distances ranging from 7 to 7.6 cm) in 15 min. With 16 channels, the device has a throughput of ~0.5 kbp/min, greater than the conventional, commercial 96-lane CAE instrumentation, which operates at ~0.4 kpb/min. An alternative design was accomplished by abandoning the constraints of VLSI wafer processing standards and adopting a custom plate size that permits the layout of long, straight channels (Figure 4.3B). The array of 48 lanes was fabricated on a large, rectangular glass plate measuring 53 × 13 cm. Substrates of this size are difficult to work with, requiring nonstandard processing equipment and large baths of dangerous glass etchants. Furthermore, reproducible thermal compression bonding becomes increasingly problematic as the device surface area increases. Of greater note here is the individual channel design, in which a 50-cm-long channel is terminated with a single well at each end with an effective separation distance of 46.5 cm. In lieu of a cross-injector, this device operates identically to a standard capillary. The penalty for abandoning the cross-injector is manifested in the 2.5-h
66
Analytical Techniques in DNA Sequencing
A
Waste Cathode Sample
Anode
B
7.2 cm
50 cm
FIGURE 4.3 Prototype µCAE sequencing devices. (A) A 16-lane array on a 4-in.-diameter glass wafer. The 16 standard, individually addressed cross-injectors line the top of the array and the channels converge at the scanning region near the bottom of the device. The magnified view shows the structure used to make the total column length identical for each channel. (From SR Liu et al., Proc Natl Acad Sci USA 97:5369–5374, 2000. With permission.) (B) A 48-lane device on a rectangular 21 × 5 in. glass plate. Two rows of 24 channels are staggered. Each 50-cm-long channel is comprised of a sample inlet and outlet. (From C Backhouse et al., Electrophoresis 21:150–156, 2000. With permission.)
run time necessary to acquire 640 bases with accuracy ≥98%.38 Array data for this device have yet to be presented. The only alternative method for increasing effective separation distance while maintaining a compact, VLSI-compatible wafer size is to fold the channel into a serpentine geometry. Serpentine channel geometries maximize space utilization on the wafer; however, they necessitate the introduction of turns in the separation path. Early in the microchip CE literature, turns incorporated in the separation portion of the device were identified as a potential source of geometric dispersion.18 The source of this geometric dispersion is the path length difference between the inner and outer radii of the turn, and was dubbed the “racetrack effect.” Given a set of cars traveling at equal velocity around a racetrack, those vehicles closest to the inside corner of the turn have a shorter path length to traverse, thus completing the turn more quickly than those traversing the outer radius. Electrophoresing molecules behave in an identical fashion, and turns tend to tilt separating bands of analyte. Culbertson and coworkers39 described the dependence of this phenomenon in terms of the width
Microfabricated DNA Sequencing Devices
67
added to a band, ∆l, by a turn with a channel width, w, and turning an angle, θ, as the product of these components. This effect was analyzed in detail by Paegel et al.,40 who used a novel rotary scanner to interrogate the same separation at multiple points. The dramatic effect of turns on separations of DNA digest ladders is presented in the left frame of Figure 4.4. Here, fragments of the φX174 HaeIII digest are crossinjected and separated in a serpentine channel containing two U-shaped turns. Three detection points along the course of the channel (before a turn, x, after a left turn, y, and after a right turn, z) illustrate the effect of the turn on band morphology. At x, the bands are substantially orthogonal to the direction of electromigration, while at y, the bands have been tilted by the racetrack effect. After the right turn, the bands are restored to their original orientation, but signal intensity and resolution have decreased due to transverse diffusion while the bands traveled in a tilted orientation. Electropherograms in the lower left frame of Figure 4.4 demonstrate the peak shape as seen by detecting at points x, y, and z. The peaks at y are extremely broad and unresolved due to the tilted band orientation. Because the severity of band tilting was expected to be proportional to the channel width, w, Paegel et al.40 introduced the concept of a tapered turn, or “hyper-turn,” in which the channel width is constricted in the region of the turn. The effect on the separation is presented in the right frame of Figure 4.4. Here, we see that the bands remain substantially orthogonal to the direction of electromigration at y, and the peaks in the corresponding electropherogram remain sharp and well resolved. Utilizing the optimal tapering geometry, the serpentine channels operate at 91% the theoretical efficiency of a comparable straight-channel device. Numerical optimizations of the hyper-turn design have suggested asymmetrically tapered structures that will potentially further diminish geometry dispersion introduced by turns.41,42 With the optimal hyper-turn geometry in hand, the first high-throughput µCAE DNA sequencing bioprocessor was fabricated on a 150-mm-diameter glass wafer. The channel layout schematic, presented in Figure 4.5, is based on the radial array design developed by Mathies’ group in 1999.34 In the design, 48 “doublet” structures are arrayed around a common, central anode reservoir. Each doublet, shown in the bottom portion of Figure 4.5, comprises two sample wells addressed by common waste and cathode reservoirs, halving the number of required reservoirs for crossinjection. As before, analyte is injected through the intersection of channels by driving it toward the waste reservoir, and the plug is separated by driving it down the 15.9 cm serpentine separation channel. As the plug approaches the center of the device, fluorescence is detected by the Berkeley rotary scanning confocal microscope, which is presented in Figure 4.6. Developed by Mathies’ group,34 the “chip scanner” directs 488-nm laser excitation through the hollow shaft of a stepper motor. A rhomb prism displaces the beam 1 cm from the axis of rotation into a 0.7 NA 60× microscope objective. The objective collects multispectral fluorescence from the migrating DNA sequencing fragments, passing the light back through the same optical path and through the dichroic beamsplitter to a four-color detector housing. Here, fluorescence is sequentially sorted into four color channels, spatially filtered, and detected by four PMTs. The µCAE bioprocessor sits on a heated stage directly above the rotary scanning objective. An elastomeric buffering loop fixed to the top of the bioprocessor creates two 3-ml concentric and electrically isolated buffer moats for fluidically
68
Analytical Techniques in DNA Sequencing
x
y
z
x
y
z
y
Fluorescence
x
0
y
z
x
x
x
y
y
z
z 20
40
60
80
0 Time (s)
20
40
60
y
z
80
FIGURE 4.4 The effect of turns on separation quality in folded channels. U-shaped turns introduce dispersion and disrupt separation quality (left side). Bands of the same separation imaged before a turn (x), after a left turn (y), and after a second right turn (z), show a tilting distortion at y due to the racetrack effect. The opposing turn rectifies the bands, but signal and resolution are lost due to lateral diffusion. Hyper-turns mitigate the racetrack effect, maintaining separation performance and signal intensity (right side). Peaks in the corresponding electropherogram retain resolution and signal intensity at all positions. (From BM Paegel et al., Anal Chem 72:3030–3037, 2000. With permission.)
Microfabricated DNA Sequencing Devices
69
A
B
Sample
Cathode Waste C
FIGURE 4.5 The 96-lane µCAE DNA sequencing bioprocessor. (A) The 48 identical doublet structures are arrayed around a common anode at the center of the device. (B) Expanded view of a doublet. Each injector contains two different sample reservoirs addressed by a common cathode and waste reservoir located in the center of the injector. Channels leading away from the injection intersection are fluidically balanced by using different channel widths. (C) The serpentine channel contains four hyper-turns for an effective channel length of 15.9 cm. (From BM Paegel et al., Proc Natl Acad Sci USA 99:574–579, 2002. With permission.)
addressing all cathode and waste ports with enough buffer to sustain electrophoresis for 30 min. An acrylic 96-pin electrode ring electrically addresses the sample wells on the periphery of the bioprocessor. Filling the array with viscous LPA sequencing matrix, as well as high-pressure water-mediated removal of the matrix, is accomplished using a loader device developed by Scherer et al.43 Sequencing products of single-stranded M13mp18 run in all 96 lanes are shown in a gel image format in Figure 4.7. Each vertical section of the image corresponds to one lane of output from the bioprocessor, and each band within a lane represents
70
Analytical Techniques in DNA Sequencing
Sample Voltage
Sample Ring
Cathode Voltage and Buffer Supply
Elastomer Buffer Loop
Waste Voltage and Buffer Supply
Bioprocessor Wafer
Heated Stage
Rhomb
60 x 0.7 NA Objective
Hollow-Shaft Stepper Motor Beamsplitter
4-Color PMT Housing
Ar+ Laser 488 nm
FIGURE 4.6 The Berkeley four-color rotary chip scanner and an exploded view of the assembled bioprocessor. An acrylic ring electrode array individually addresses the 96 peripheral sample reservoirs. An elastomeric buffer loop creates two annular, concentric, electrically isolated troughs (3-ml capacity) that separately address the cathode and waste wells. This assembly is placed on the heated stage of the four-color chip scanner. Excitation from an Ar+ laser (488 nm) is reflected from a dichroic beamsplitter through the hollow shaft of a stepper motor. The beam is translated 1 cm from the axis of rotation by a rhomb prism and focused onto the channels through a 60× 0.7 NA microscope objective. Fluorescence is collected by the same objective and passed through the beamsplitter to the four-color PMT (photomultiplier) housing for spectral sorting and spatial filtering prior to detection. (Adapted from Emrich et al., 2002.)
one called base. Of the 96 lanes, only one lane failed to produce sequence of any appreciable length due to a defect in the lithography. An average of 430 bases with ≥99% accuracy were called per channel and the entire analysis required only 24 min. A plot of the average phred quality value as a function of base position in a 10-base moving window is shown in Figure 4.8. This plot indicates that the average accuracy equals or exceeds 99.9% for the majority of the run.44 The rapid decline in quality at the end of the run was due to the properties of the LPA matrix used in this particular experiment. Using an optimized, blended LPA as described in previous single-channel experiments, the bioprocessor produces on average 621 bases to ≥99% accuracy in 28 min. This level of throughput corresponds to ~2 kbp/min, fivefold higher than currently deployed 96-lane CAE instruments, and even surpassing the 384-lane CAE instruments currently in testing.
Microfabricated DNA Sequencing Devices
71
8
RUN TIME (min)
12
16
20
24
1
24
48
72
96
LANE NUMBER
FIGURE 4.7 Gel image from the 96-lane µCAE DNA sequencing bioprocessor. Lanes are represented in the vertical dimension. Each horizontal band corresponds to one called base. The image contains 41,000 bases called with ≥99% accuracy acquired in only 24 min.
APPLICATIONS
OF THE
µCAE BIOPROCESSOR
With the expanded sequencing capacity provided by µCAE, polymorphism detection and screening based on DNA sequencing becomes a tractable and, in fact, very attractive alternative to modern genotyping techniques. To demonstrate this concept, Blazej et al.45 developed a novel, sequencing-based polymorphism screening and
Analytical Techniques in DNA Sequencing
40
99.99
30
99.9
20
99
10
90
0 0
Accuracy (%)
PHRED Score
72
100 200 300 400 500 Base Position
FIGURE 4.8 Average phred quality value in 10-base windows as a function of base position for the data in Figure 4.7. The average read length over 96 lanes was 430 bp, defined as the number of phred q ≥ 20 (accuracy ≥ 99%) bases. In-house synthesized linear polyacrylamide (4.5% T, 7 M urea, 1× TTE), 50°C, ET dye-primer chemistry, M13mp18 ssDNA template, 200 V/cm, 24-min operation. (From BM Paegel et al., Proc Natl Acad Sci USA 99:574–579, 2002. With permission.)
detection assay called Polymorphism Ratio Sequencing (PRS). In this technique, two sequences are compared by creating single base extension ladders via the Sanger cycle-sequencing reaction, but utilizing a different pooling scheme from conventional four-color sequencing. DNA from a reference individual (or population) and DNA from a sample individual (or population) are used to generate the four standard single-base extension ladders using dye-primer sequencing chemistry. In the case of the reference individual for the A ladder, the ET-R6G primer is used, whereas for the sample individual, the A ladder is prepared with the ET-FAM primer. Similarly, the C ladder for the reference would be prepared using the ET-ROX primer for the reference and the ET-TAMRA primer for the sample. To prepare the A/C PRS sample, these four ladder reactions are pooled, precipitated, and electrophoretically resolved on the bioprocessor in an identical fashion to a standard four-color sequencing sample. An analogous pooling scheme for the T and G ladders is used to generate the T/G PRS trace to provide complete coverage of all bases. To detect polymorphisms between the sample and reference sequence, extension ladders are color-corrected and normalized utilizing standard base-calling processing procedures. The corrected output is then examined for variations in signal intensity for a given base identity. The plot of the squared difference of intensities, for example, from the T ladder for the sample and reference individual is the PRS plot (∆2 plot), and peaks in this plot indicate the presence of a polymorphic base. Examples of PRS output from the bioprocessor are presented in Figure 4.9. At top, box A shows the A/C and T/G PRS traces as well as the ∆2 plot. Along the length of the A/C trace, almost all A and C terminations are shown to overlap exactly, and the PRS plot in these locations is essentially null. In the middle of the traces, however, a polymorphism shows an A → G transition, and is manifested as a peak disappearing from the blue (sample, A) channel of the A/C trace and appearing as a blue G (sample, G) in the T/G trace. The polymorphic base is clearly identified in the ∆2 plot. Box B presents a transversion polymorphism, A → C, in which a peak has shifted from the blue channel (sample, A) to the green channel (sample, C). Although the polymorphic peaks overlap, the relative reference-to-sample signal ratio for the A and C traces has
Microfabricated DNA Sequencing Devices
73
A ∆2 A/C T/G
B
TCACACTACTCCCCTA G TCTAA CAACGTAAAA
∆2
A/C
ACAA CCCACC A CA CCAAACAACCA A
ACA
C
∆2
T/G
G GG A GGA
T
TT T GTGTGTT TT TT C
TG
Control 12s Region Cyt b rRNA ND6 16s rRNA ND1
ND5 Hu mtDNA Map ND4
ND2
6 ase ATP ase8 ATP
COI
ND4L ND3 COIII
COII
FIGURE 4.9 High-speed PRS analysis of human mtDNA. (Top) Examples of different polymorphism types. The PRS (∆2) plot is shown above the PRS traces. (A) Transition polymorphisms result in a peak disappearing from one PRS trace (in this case, the A/C trace) and appearing in its companion trace (G/T trace). (B) Transversion polymorphisms result in peaks changing color in the same PRS trace. (C) Due to fewer interfering peaks, extended PRS read lengths allow polymorphism detection in the classically low-quality region at the end of the run. (Bottom) Tiled PRS traces provide complete coverage of the human mitochondrial genome. The plots are overlaid on an mtDNA map showing the polymorphism positions relative to mitochondrial genes. (From RG Blazej et al., Genome Res 13:287–293, 2003. With permission.)
changed and is reflected in the ∆2 plot. As a final demonstration of the utility of this technique, box C presents polymorphism detection in the classically low-quality region at the end of the sequencing run. Because any given PRS trace contains fewer interferences than a standard sequencing sample (containing all four base terminations) and because relative, not absolute signals are compared, greatly increased effective read lengths are possible, permitting polymorphism detection in regions that would otherwise contain no useful sequence information.45 The PRS method was applied to the analysis of human mitochondrial DNA (mtDNA) from two individuals to screen for polymorphic bases. The PRS traces
74
Analytical Techniques in DNA Sequencing
and ∆2 plot are overlaid on a genetic map of the mtDNA heavy strand in the bottom frame of Figure 4.9. Polymorphic bases are indicated as peaks in the ∆2 plot shown in black on the outside of the map. Highly condensed PRS traces spanning the entire mtDNA genome are shown as the overlapping, unresolved peaks immediately adjacent to the map for scale comparison. The PRS analysis of the two individuals uncovered 30 previously published polymorphisms as well as 6 novel polymorphisms, an effective demonstration of the advantages of adopting a global screening technique. An entire comparative analysis of the two genomes was completed in one operation of the bioprocessor, requiring only 29 min for separation.45
PROSPECTS: BIOPROCESSORS WITH INTEGRATED CHEMISTRIES Although the absolute sequencing throughput of µCAE devices is impressive in the context of separation analysis alone, the fivefold decrease in analysis time pales in comparison to the total time required to process a sample from a BAC clone library to the front end of the electrophoresis device. For example, clone propagation in cell culture requires incubation and growth steps that may exceed 18 hours. Thus, the holy grail of bioanalytical instrumentation is the development of a process that eliminates lengthy cell growth steps, reduces the standard reaction volume from the present day values of 10 µl to 100 nl or lower, integrates all sample handling and transfer steps to eliminate tracking errors and sample contamination, and facilitates submicroliter fluid manipulation. To this end, research emphasis is shifting toward devices that will expedite and miniaturize the time-consuming chemistry and molecular biology steps that dominate the modern sequencing sample preparation process.
INTEGRATED DNA AMPLIFICATION The DNA sequencing process universally relies on thermal cycling for the creation of dideoxy-terminated extension fragments, and in some cases also makes use of PCR to generate template DNA from subclones of a large-insert (e.g. BAC, YAC) library. These reactions are problematic in high- and low-throughput settings for three key reasons: (1) the reagents (polymerase cocktails, primers, etc.) used for thermally cycled reactions are costly; (2) large-volume reactions (5 to 20 µl) occur in plastic tubes that conduct heat poorly; (3) thermal cycling blocks typically have large thermal masses with low heating rates (3°C/s) and even lower cooling rates (1°C/s). Of the microfabricated separation devices we have considered thus far, injected sample volumes are on the order of 1 nl, and thus an integrated thermal cycling system that takes advantage of the microchip’s native nanoliter-scale handling capabilities could address reagent cost, preparation time, and sample transfer problems. Woolley and coworkers46 first demonstrated hybrid integrated PCR-CE in a silicon microreactor attached to a microfabricated CE device in 1996. As a consequence of the low thermal mass of the reactor system, thermal cycling time was 25 s, compared to cycle times of 2 to 6 min in a commercial thermal cycler. Once cycling was complete, product was directly injected into the microfabricated CE system for high-speed electrophoretic resolution. This work highlighted the potential
Microfabricated DNA Sequencing Devices
75
for microchips to eliminate sample transfer between processing steps, instead relying solely on electromigration to move the sample from reactor to CE column.46 These experiments spurred subsequent studies of online PCR and cell lysis on a microfabricated device.47,48 but the reaction volume was never reduced to the nanoliter scale. However, in 2000, Lagally et al.49 described the low-volume amplification of M13 template DNA in which a 280-nl reactor was rapidly thermally cycled (20 cycles in 10 min), and the resulting product was directly injected onto a microfabricated CE column for electrophoretic analysis. Subsequent integration of heating and temperature-sensing elements with the nanoliter reactor further advanced the capabilities of this miniaturized analytical instrumentation.50 Although these nanoliter-scale reactions provide significant improvements in thermal cycling speed and reagent consumption, the synthesis and analysis of DNA sequencing products presents some unique challenges. PCR generates a monodisperse, double-stranded product population, which allows nonspecific, multiple-site labeling by intercalating fluorescent dyes. The presence of literally hundreds of fluorophores per molecule allows detection of these species down to the single-molecule limit.51 In contrast, the polydisperse DNA sequencing sample comprises approximately 1000 different single-stranded species, each of which is singly labeled. Purification and preconcentration of this sample is necessary to reach the requisite detection sensitivity, but conventional macroscale purification methodologies are incompatible with microchip-scale synthesis, thus necessitating a nanovolume sample preparation step prior to CE analysis.
INTEGRATED DNA PURIFICATION In 1998, Ruiz-Martinez and Salas-Solano52,53 published studies on the effects of the sequencing reaction composition (specifically, template and chloride concentration) on sequencing read length. They found that the longest read lengths were obtained from samples that contained a minimal concentrations of chloride ions and template molecules. These interferences were efficiently removed in a two-step process involving serial treatment with ion exchange followed by size exclusion spin columns.52,53 A cheaper, more commonly adopted alternative to this protocol is ethanol precipitation. Ethanol precipitation, however, is extremely difficult to automate efficiently due to multiple sample transfer and centrifugation steps, suffers from poor (~65%) yield, and requires ~1 h to complete. Importantly, precipitation does not remove template, which can have the most detrimental effect on separation quality. A miniaturized purification technology is needed that will address the automation, speed, and cost issues associated with sample purification while providing the requisite sample purity. A variety of methods for sample purification and preconcentration have been presented in the microchip electrophoresis literature such as solid phase extraction (SPE) and preconcentration using bead-based chromatography reagents,54 and a porous glass frit allowing continuous preconcentration of DNA prior to injection.55 None of these strategies accomplished all three objectives of desalting the sample, removing template, and selectively preconcentrating the sequencing fragments. A solution to this problem was to be found in exploiting the self-complementarity of DNA itself.
76
Analytical Techniques in DNA Sequencing
H N
( )6
GTTGTAAAACGACGGCCAGT
O
Acrylamide TEMED APS g aacgac
gttgtaa
ac
g
gttgta aaac g
gt tg ta a
aa
cg
acg
g aacgac gttgtaa
Capture Site 5’
gt tg
ta
aa
ac
ga
cg
gttgta a
aacg
acg
M13 (-28) Reverse Primer Insert DNA 3’
M13 (-40) Forward Primer
M13mp18
FIGURE 4.10 (Middle) Addition of the 5´-methacryl-modified capture oligo to a solution of acrylamide with radical-generating catalysts APS and TEMED yields a DNA-acrylamide capture copolymer. (Bottom) The M13mp18 cloning vector map. The capture sequence (gray) is held between the insert DNA site and the universal -40 forward M13 sequencing primer site. Extension products from the primer contain the capture sequence followed by the insert DNA sequence of interest.
In 1992, Baba and coworkers56 at Tokushima introduced the concept of covalently linking DNA oligos of a chosen sequence to a polymeric gel matrix. An example structure of such an oligo is presented in Figure 4.10. The oligo is synthesized with a hexyl spacer separating the 5´-end from a methacryl group, which allows participation in the radical-initiated polymerization of acrylamide. When mixed with a low percentage solution of acrylamide and catalyzed with APS and TEMED, a DNAacrylamide copolymer is formed, as shown in the middle frame of Figure 4.10, where the solid line represents the C–C backbone of the polymer. The gray oligos, or capture oligos, appear randomly along the backbone (~0.001% compared to acrylamide). This DNA-acrylamide copolymer matrix is capable of sequence-specific capture of DNA that is electrophoresed through it, providing a one-step selective capture, preconcentration, and cleanup. Sequencing fragments are selectively captured by choosing a capture sequence that is specific only to enzymatic extension products. The bottom panel of Figure 4.10 schematically presents a map of the M13mp18 cloning vector in the vicinity of the polylinker cloning site containing
Microfabricated DNA Sequencing Devices
77
the insert DNA to be sequenced. Between the universal −40 forward M13 sequencing primer site and the beginning of the polylinker cloning site lies a region of constant vector sequence. Sequencing products of all insert DNA cloned into this vector will contain the capture sequence. The length of the capture oligo should be chosen such that the probability of the complementary sequence appearing in the target genome is minimized, and ideally should be short enough to allow full denaturation at the sequencing process temperature (a 19-mer satisfies these requirements for a process temperature of 65°C and a target genome of 1 Gbp). Driving an unpurified DNA sequencing sample through this capture matrix will cause the sequencing products to bind selectively to the matrix and preconcentrate to ~10 µM. Contaminating ionic species such as unspent nucleotide triphosphates, chloride, primer, and buffer components have no specificity for the capture matrix and will electrophorese through the capture matrix to the waste. Template DNA is too large to enter the polyacrylamide matrix appreciably (M13mp18 clones will be ~8 kbp) and will be excluded. This method of sample purification is advantageous for two primary reasons: (1) it combines solid-phase immobilization strategies with the high activity intrinsic of a solution phase reactions, and (2) it is entirely electrokinetically driven, obviating the need for robotic sample transfer and hydrodynamic driving apparatus. An integrated bioprocessor for DNA sequencing sample purification followed by high-speed microchip electrophoresis was presented by Paegel et al. in 2002. The serpentine doublet separation channels and injector geometry were derived from the first-generation 96-lane bioprocessor, with a capture chamber placed in line with the cross-injector. A schematic of the injection microfluidics and device operation is shown in Figure 4.11. The 60-nl capture chamber has a 1-mm-wide body and 100-µm-wide inlet and outlet arms. The sample inlet side of the chamber is split between the sample input arm leading to the sample reservoir and a coupling arm leading to the cross-injector. Prior to operation, the entire device is filled with sequencing matrix and then the capture chamber is filled with capture matrix. All wells are filled with run buffer unless otherwise noted. In product binding mode, the device is heated to 50°C to maximize DNA hybridization kinetics (the oligoDNA duplex TM = 60.4°C), and DNA sequencing sample taken from the thermal cycler is driven electrophoretically through the capture chamber from well “S.” DNA binding selectively occurs at the front taper of the chamber where the local electrophoretic flow rate is decreased due to the rapid increase in local conductivity. Product binding is usually complete in 90 s. Product washing is accomplished by evacuating the sample well and replacing it with fresh run buffer, followed by electrophoresis for an additional 30 s to remove residual low-mobility species such as primer. The bound product is released from the capture matrix by elevating the device to the DNA sequencing process temperature (67°C) and performing a standard cross-injection as previously discussed. Sequence output from the integrated DNA sequencing purification processor is presented in Figure 4.12. In the top panel, the C terminations of three four-color sequencing experiments are shown. Trace A shows terminations obtained from the integrated purification process, while traces B and C were obtained by running the same sequencing sample on the first-generation 96-lane bioprocessor. Trace B is obtained from ethanol-precipitated sequencing sample while trace C is the result
78
Analytical Techniques in DNA Sequencing
+
+
S
Product Binding
Product Washing
+
+
+
CE Separation
Injection
FIGURE 4.11 Schematic operation of a microfabricated device for integrated sequencing sample purification and CE analysis. Unpurified sequencing reaction mix (S, white) is electrophoretically driven through the capture matrix in the chamber and concentrated in the tapering region of the capture chamber. After 90 s, the input reservoir is cleaned and fresh buffer (B) is used to wash the bound product electrophoretically. During injection, the capture matrix–product duplex is thermally denatured and free, purified product is electrophoretically driven through the injection cross to the waste. Separation is initiated by applying a large positive potential to the central anode, drawing ~1 nl purified sample into the CE separation column. A small positive back bias is applied to the capture chamber and waste reservoirs to prevent leakage during the run.
of injecting unpurified sample. The signal intensity of the integrated purification device is on average 85% of the corresponding peak from the ethanol-precipitated sample, whereas the unpurified sample yielded peaks that were ≤10%. An examination of the early region of these electropherograms shows the specificity of the capture matrix exclusively for the sequencing extension fragments. In traces B and C, the unincorporated primer peak and first four terminations are shaded in black. These five peaks are missing from the capture matrix-purified sample because the fluorescent primers are not captured by the matrix, and the first four terminations are all contained within the capture sequence itself. These fragments have melting temperatures lower than the binding process temperature, and therefore are not captured. High-speed microchip electrophoresis of the bound product yielded 560 bases of ≥99% accuracy. This microfluidic circuitry reduces the time for sample purification 10-fold, reduces the process volume 100-fold, and eliminates all associated robotic transfer steps. This result provides dramatic evidence that microchip-level integration is evolving beyond merely expediting separations and toward a completely independent system for transferring, reacting, purifying, as well as analyzing samples.57
Microfabricated DNA Sequencing Devices
79
A
B
C
10
15
20
25
30
40
99.99
30
99.9
20
99
10
90
0
200
400
Accuracy (%)
PHRED Score
5
600
Base Position
FIGURE 4.12 Integrated, high-speed oligonucleotide-capture purification of DNA sequencing products. (Top) C-terminations of four-color microchip CE sequencing runs for comparison of different purification methods. (A) Integrated oligonucleotide-capture purification followed by microchip CE. (B) Ethanol-precipitated sequencing sample that was resuspended in 50% formamide solution in DI H2O to 1× manufacturer’s specification. (C) Sample that was injected without purification. The magnified traces show the first 60 bases from each trace. Darkened peaks in traces B and C show the primer peak and the first four C terminations contained in the capture sequence, which are not present in the capture-purified sample. (Bottom) Phred analysis of the integrated capture purification microchip CE DNA sequencing run, showing 560 phred q ≥ 20 bases called. Integrated purification required 2 min, and microchip DNA sequencing was complete in 30 min. (From BM Paegel et al., Anal Chem 74:5092–5098, 2002. With permission.)
The miniaturization of the current DNA sequencing processes in an integrated µCAE format will result in dramatic decreases in reagent consumption, analysis time, and reliance on robotics, centrifuges, and other large, expensive, and unreliable laboratory equipment. The next generation of commercial microfluidic DNA sequencers will contain entirely integrated nanoliter fluidic networks for sorting and distributing individual subclones, lysing and high-speed amplification of the
80
Analytical Techniques in DNA Sequencing
template DNA molecules, isolating template amplicons for delivery to integrated cycle-sequencing reactors, sequencing product preconcentration and purification, and finally electrophoretic resolution.58 We envision a sequencing lab of the future where microtiter plates, pipettors, test tubes, and macro robotics have been relegated to museums, replaced by stacks of highly efficient microchip bioprocessors.
ACKNOWLEDGMENTS This work was supported by grants from the National Institutes of Health (HG01399) and from the Director, Office of Science, Office of Biological and Environmental Research of the U.S. Department of Energy under Contract DEFG91ER61125. B.M.P. acknowledges NIH fellowship support from the Berkeley Program in Genomics (T32 HG00047). Charles Emrich provided key insight on microfabrication techniques and circuit design, James Scherer designed the Berkeley four-color rotary confocal scanner, and Eric Lagally provided expertise on PCR. Additionally, we thank the entire Mathies Microchip Group for providing valuable input in the conception and execution of the µCAE DNA sequencing system.
REFERENCES 1. ES Lander, LM Linton, B Birren et al. Initial sequencing and analysis of the human genome. Nature 409:860–921, 2001. 2. LM Smith, JZ Sanders, RJ Kaiser, P Hughes, C Dodd, CR Connell, C Heiner, SBH Kent, LE Hood. Fluorescence detection in automated DNA-sequence analysis. Nature 321:674–679, 1986. 3. JM Prober, GL Trainor, RJ Dam, FW Hobbs, CW Robertson, RJ Zagursky, AJ Cocuzza, MA Jensen, K Baumeister. A system for rapid DNA sequencing with fluorescent chain-terminating dideoxynucleotides. Science 238:336–341, 1987. 4. S Tabor, CC Richardson. DNA-sequence analysis with a modified bacteriophage-T7 DNA-polymerase. Proc Natl Acad Sci USA 84:4767–4771, 1987. 5. S Tabor, CC Richardson. A single residue in DNA-polymerases of the Escherichiacoli DNA-polymerase-I family is critical for distinguishing between deoxyribonucleotides and dideoxyribonucleotides. Proc Natl Acad Sci USA 92:6339–6343, 1995. 6. JY Ju, CC Ruan, CW Fuller, AN Glazer, RA Mathies. Fluorescence energy-transfer dye-labeled primers for DNA sequencing and analysis. Proc Natl Acad Sci USA 92:4347–4351, 1995. 7. RA Mathies, XC Huang. Capillary array electrophoresis — an approach to highspeed, high-throughput DNA sequencing. Nature 359:167–169, 1992. 8. H Kambara, S Takahashi. Multiple-sheathflow capillary array DNA analyzer. Nature 361:565–566, 1993. 9. HJ Crabtree, SJ Bay, DF Lewis, JZ Zhang, LD Coulson, GA Fitzpatrick, SL Delinger, DJ Harrison, NJ Dovichi. Construction and evaluation of a capillary array DNA sequencer based on a micromachined sheath-flow cuvette. Electrophoresis 21:1329– 1335, 2000. 10. T Sasaki. The rice genome project in Japan. Proc Natl Acad Sci USA 95:2027–2028, 1998.
Microfabricated DNA Sequencing Devices
81
11. MD Adams, SE Celniker, RA Holt, et al. The genome sequence of Drosophila melanogaster. Science 287:2185–2195, 2000. 12. P Dehal, P Predki, AS Olsen, A Kobayashi, P Folta, S Lucas, M Land, A Terry, CLE Zhou, S Rash, Q Zhang, L Gordon, J Kim, C Elkin, MJ Pollard, P Richardson, D Rokhsar, E Uberbacher, T Hawkins, E Branscomb, L Stubbs. Human chromosome 19 and related regions in mouse: Conservative and lineage-specific evolution. Science 293:104–111, 2001. 13. A Manz, DJ Harrison, EMJ Verpoorte, JC Fettinger, A Paulus, H Ludi, HM Widmer. Planar chips technology for miniaturization and integration of separation techniques into monitoring systems — capillary electrophoresis on a chip. J Chromatogr 593:253–258, 1992. 14. DJ Harrison, A Manz, ZH Fan, H Ludi, HM Widmer. Capillary electrophoresis and sample injection systems integrated on a planar glass chip. Anal Chem 64:1926–1932, 1992. 15. PC Simpson, AT Woolley, RA Mathies. Microfabrication technology for the production of capillary array electrophoresis chips. Biomed Microdevices 1:7–26, 1998. 16. HD Tan, ES Yeung. Integrated on-line system for DNA sequencing by capillary electrophoresis: From template to called bases. Anal Chem 69:664–674, 1997. 17. DJ Harrison, K Fluri, K Seiler, ZH Fan, CS Effenhauser, A Manz. Micromachining a miniaturized capillary electrophoresis-based chemical-analysis system on a chip. Science 261:895–897, 1993. 18. SC Jacobson, R Hergenroder, LB Koutny, RJ Warmack, JM Ramsey. Effects of injection schemes and column geometry on the performance of microchip electrophoresis devices. Anal Chem 66:1107–1113, 1994. 19. SC Jacobson, R Hergenroder, AW Moore, JM Ramsey. Precolumn reactions with electrophoretic analysis integrated on a microchip. Anal Chem 66:4127–4132, 1994. 20. K Seiler, ZHH Fan, K Fluri, DJ Harrison. Electroosmotic pumping and valveless control of fluid-flow within a manifold of capillaries on a glass chip. Anal Chem 66:3485–3491, 1994. 21. SC Jacobson, R Hergenroder, LB Koutny, JM Ramsey. Open-channel electrochromatography on a microchip. Anal Chem 66:2369–2373, 1994. 22. AT Woolley, RA Mathies. Ultra-high-speed DNA fragment separations using microfabricated capillary array electrophoresis chips. Proc Natl Acad Sci USA 91:11348–11352, 1994. 23. AT Woolley, RA Mathies. Ultra-high-speed DNA sequencing using capillary electrophoresis chips. Anal Chem 67:3676–3680, 1995. 24. CS Effenhauser, A Paulus, A Manz, HM Widmer. High-speed separation of antisense oligonucleotides on a micromachined capillary electrophoresis device. Anal Chem 66:2949–2953, 1994. 25. MC Ruiz-Martinez, J Berka, A Belenkii, F Foret, AW Miller, BL Karger. DNAsequencing by capillary electrophoresis with replaceable linear polyacrylamide and laser-induced fluorescence detection. Anal Chem 65:2851–2858, 1993. 26. D Schmalzing, A Adourian, L Koutny, L Ziaugra, P Matsudaira, D Ehrlich. DNA sequencing on microfabricated electrophoretic devices. Anal Chem 70:2303–2310, 1998. 27. SR Liu, YN Shi, WW Ja, RA Mathies. Optimization of high-speed DNA sequencing on microfabricated capillary electrophoresis channels. Anal Chem 71:566–573, 1999.
82
Analytical Techniques in DNA Sequencing 28. D Schmalzing, N Tsao, L Koutny, D Chisholm, A Srivastava, A Adourian, L Linton, P McEwan, P Matsudaira, D Ehrlich. Toward real-world sequencing by microdevice electrophoresis. Genome Res 9:853–858, 1999. 29. W Goetzinger, L Kotler, E Carrilho, MC Ruiz-Martinez, O Salas-Solano, BL Karger. Characterization of high molecular mass linear polyacrylamide powder prepared by emulsion polymerization as a replaceable polymer matrix for DNA sequencing by capillary electrophoresis. Electrophoresis 19:242–248, 1998. 30. O Salas-Solano, D Schmalzing, L Koutny, S Buonocore, A Adourian, P Matsudaira, D Ehrlich. Optimization of high-performance DNA sequencing on short microfabricated electrophoretic devices. Anal Chem 72:3129–3137, 2000. 31. L Koutny, D Schmalzing, O Salas-Solano, S El-Difrawy, A Adourian, S Buonocore, K Abbey, P McEwan, P Matsudaira, D Ehrlich. Eight hundred base sequencing in a microfabricated electrophoretic device. Anal Chem 72:3388–3391, 2000. 32. AT Woolley, GF Sensabaugh, RA Mathies. High-speed DNA genotyping using microfabricated capillary array electrophoresis chips. Anal Chem 69:2181–2186, 1997. 33. PC Simpson, D Roach, AT Woolley, T Thorsen, R Johnston, GF Sensabaugh, RA Mathies. High-throughput genetic analysis using microfabricated 96-sample capillary array electrophoresis microplates. Proc Natl Acad Sci USA 95:2256–2261, 1998. 34. Y Shi, PC Simpson, JR Scherer, D Wexler, C Skibola, MT Smith, RA Mathies. Radial capillary array electrophoresis microplate and scanner for high-performance nucleic acid analysis. Anal Chem 71:5354–5361, 1999. 35. IL Medintz, CCR Lee, WW Wong, K Pirkola, D Sidransky, RA Mathies. Loss of heterozygosity assay for molecular detection of cancer using energy-transfer primers and capillary array electrophoresis. Genome Res 10:1211–1218, 2000. 36. CA Emrich, H Tian, IL Medintz, RA Mathies. Microfabricated 384-lane capillary array electrophoresis bioanalyzer for ultrahigh-throughput genetic analysis. Anal Chem 74:5076–5083, 2002. 37. SR Liu, HJ Ren, QF Gao, DJ Roach, RT Loder, TM Armstrong, QL Mao, I Blaga, DL Barker, SB Jovanovich. Automated parallel DNA sequencing on multiple channel microchips. Proc Natl Acad Sci USA 97:5369–5374, 2000. 38. C Backhouse, M Caamano, F Oaks, E Nordman, A Carrillo, B Johnson, S Bay. DNA sequencing in a monolithic microchannel device. Electrophoresis 21:150–156, 2000. 39. CT Culbertson, SC Jacobson, JM Ramsey. Dispersion sources for compact geometries on microchips. Anal Chem 70:3781–3789, 1998. 40. BM Paegel, LD Hutt, PC Simpson, RA Mathies. Turn geometry for minimizing band broadening in microfabricated capillary electrophoresis channels. Anal Chem 72:3030–3037, 2000. 41. SK Griffiths, RH Nilson. Low dispersion turns and junctions for microchannel systems. Anal Chem 73:272–278, 2001. 42. JI Molho, AE Herr, BP Mosier, JG Santiago, TW Kenny, RA Brennen, GB Gordon, B Mohammadi. Optimization of turn geometries for microchip electrophoresis. Anal Chem 73:1350–1360, 2001. 43. JR Scherer, BM Paegel, GJ Wedemayer, CA Emrich, J Lo, IL Medintz, RA Mathies. High-pressure gel loader for capillary array electrophoresis microchannel plates. BioTechniques 31:1150–1156, 2001. 44. BM Paegel, CA Emrich, GJ Wedemayer, JR Scherer, RA Mathies. High throughput DNA sequencing with a microfabricated 96-lane capillary array electrophoresis bioprocessor. Proc Natl Acad Sci USA 99:574–579, 2002. 45. RG Blazej, BM Paegel, RA Mathies. Polymorphism ratio sequencing: a new approach for single nucleotide polymorphism discovery and genotyping. Genome Res 13:287–293, 2003.
Microfabricated DNA Sequencing Devices
83
46. AT Woolley, D Hadley, P Landre, AJ deMello, RA Mathies, MA Northrup. Functional integration of PCR amplification and capillary electrophoresis in a microfabricated DNA analysis device. Anal Chem 68:4081–4086, 1996. 47. LC Waters, SC Jacobson, N Kroutchinina, J Khandurina, RS Foote, JM Ramsey. Multiple sample PCR amplification and electrophoretic analysis on a microchip. Anal Chem 70:5172–5176, 1998. 48. LC Waters, SC Jacobson, N Kroutchinina, J Khandurina, RS Foote, JM Ramsey. Microchip device for cell lysis, multiplex PCR amplification, and electrophoretic sizing. Anal Chem 70:158–162, 1998. 49. ET Lagally, PC Simpson, RA Mathies. Monolithic integrated microfluidic DNA amplification and capillary electrophoresis analysis system. Sens Actuator B-Chem 63:138–146, 2000. 50. ET Lagally, CA Emrich, RA Mathies. Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis. Lab Chip 1:102–107, 2001. 51. BB Haab, RA Mathies. Single-molecule detection of DNA separations in microfabricated capillary electrophoresis chips employing focused molecular streams. Anal Chem 71:5137–5145, 1999. 52. MC Ruiz-Martinez, O Salas-Solano, E Carrilho, L Kotler, BL Karger. A sample purification method for rugged and high-performance DNA sequencing by capillary electrophoresis using replaceable polymer solutions. A. Development of the cleanup protocol. Anal Chem 70:1516–1527, 1998. 53. O Salas-Solano, MC Ruiz-Martinez, E Carrilho, L Kotler, BL Karger. A sample purification method for rugged and high-performance DNA sequencing by capillary electrophoresis using replaceable polymer solutions. B. Quantitative determination of the role of sample matrix components on sequencing analysis. Anal Chem 70:1528–1535, 1998. 54. RD Oleschuk, LL Shultz-Lockyear, YB Ning, DJ Harrison. Trapping of bead-based reagents within microfluidic systems: On-chip solid-phase extraction and electrochromatography. Anal Chem 72:585–590, 2000. 55. J Khandurina, SC Jacobson, LC Waters, RS Foote, JM Ramsey. Microfabricated porous membrane structure for sample concentration and electrophoretic analysis. Anal Chem 71:1815–1819, 1999. 56. Y Baba, M Tsuhako, T Sawa, M Akashi, E Yashima. Specific base recognition of oligodeoxynucleotides by capillary affinity gel electrophoresis using polyacrylamide poly(9-vinyladenine) conjugated gel. Anal Chem 64:1920–1925, 1992. 57. BM Paegel, SHI Yeung, RA Mathies. Microchip bioprocessor for integrated nanovolume sample purification and DNA sequencing. Anal Chem 74:5092–5098, 2002. 58. BM Paegel, RG Blazej, RA Mathies. Microfluidic devices for DNA sequencing sample preparation and electrophoresis analysis. Curr Opin Biotech 14:42–50, 2003.
5
Analysis of Nucleic Acids by Mass Spectrometry Dirk van den Boom and Franz Hillenkamp
CONTENTS Introduction..............................................................................................................85 The Challenge of MALDI Mass Spectrometry for Oligonucleotide Analysis ......... 86 Sample Purification......................................................................................86 Sample Preparation for MALDI Mass Spectrometry .................................87 Ion Fragmentation........................................................................................88 Instrumentation ............................................................................................89 Quantification and Mixture Analysis ..........................................................90 Role of MALDI-TOF-MS in High-Throughput Sequence Analysis Applications ..........................................................................................90 MALDI-TOF-MS–Based DNA Sequencing and Resequencing ................91 MALDI-TOF-MS–Based SNP Scoring and Mutation Analysis ................96 Conclusions and Future Prospects ........................................................................101 References..............................................................................................................103
INTRODUCTION With the advent of the soft ionization techniques electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI), mass spectrometry (MS) has developed over the last decade into a key analytical method for the analysis of biological macromolecules. ESI and MALDI mass spectrometers are today indispensable tools in all aspects of protein research and identification. For a detailed discussion of the techniques as such and their application to the analysis of peptides and proteins, the reader is referred to Reference 1. The routine application of these techniques for the analysis of nucleic acids is only emerging at this point in time and is still much less widespread than that of proteins. The main reason for this slow introduction is the relative lability of gas-phase ions of oligonucleotides, which limits the accessible size of these ions, particularly for MALDI-MS. The availability of several well-established alternative analytical techniques also contributes to the somewhat slow penetration. The applications of mass spectrometry to the large variety of different fields in oligonucleotide research and analysis have been described in a recent review article, 85
86
Analytical Techniques in DNA Sequencing
which also contains a list of 180 references.2 The reader is directed to this review for a more complete coverage of the field, including such applications as identification of modified RNAs, DNAs, and of RNA–drug interaction, analysis of DNA–protein non-covalent complexes, to name a few. This chapter concentrates on the application of MALDI-MS to industrial-scale applications where automation and high throughput are the prime goals, requirements that are more difficult to meet by ESI and most of the mass analyzers commonly used with this ion source. In this chapter “sequencing of DNA” is taken in a somewhat loose sense, encompassing resequencing, proofreading, detection of polymorphisms, and similar applications. At least at this point in time MS is not used for de novo sequencing in competition to gel-based sequencing.
THE CHALLENGE OF MALDI MASS SPECTROMETRY FOR OLIGONUCLEOTIDE ANALYSIS A number of problems had to be solved before a routine successful MS analysis of oligonucleotides was established. First, careful sample purification is a prerequisite for MALDI and even more so for ESI-MS. Choice of the matrix and optimized preparation protocols for the samples as they are introduced into the mass spectrometer is a second, and last, but not least, molecular assays had to be developed, which take the specific requirements of the mass spectrometric analysis into account. The scientific basis for these requirements and the technical solutions are discussed in the first part of this chapter. The second part presents specific application examples.
SAMPLE PURIFICATION Oligonucleotides as analytes in conjunction with the MALDI process introduce very specific requirements for a stringent sample purification. While all phosphate groups of the oligonucleotides are dissociated in solution, they get neutralized by a proton or any of the ubiquitous cations, such as Na+ or K+, upon incorporation into the solid MALDI matrix. Following desorption of the usually singly charged oligonucleotide ions, these heterogeneous salts lead to a multiplicity of signals in the spectrum, spaced by the mass of Na or K. The larger the sequence, the more extensive the mass heterogeneity. For small polymers, these different peaks are still resolved in the spectrum, but the total number of ions for a given oligomer is distributed over many peaks, which will decrease the signal-to-noise ratio and thereby limit the sensitivity. For larger oligomers the cluster of signals will not be resolved, which again limits sensitivity, but, more importantly, will prevent a correct mass assignment. Desalting of the analytes and the matrix is commonly achieved by adding ammonium salts such as di-ammoniumcitrate,3 or by suitable treatment with ion exchange beads.4 Upon desorption, ammonia is quantitatively lost from all phosphate groups leaving the free acid ion for detection. Reversed phase purification, commonly used in protein and peptide analysis (for example, with ZipTips), has not been similarly successful for oligonucleotides. The easy availability of negative charges on the backbone and the high proton affinity of the A, C, and G-bases make oligonucleotides amenable to an analysis in the positive as well as the negative ion mode, usually with comparable
Analysis of Nucleic Acids by Mass Spectrometry
87
signal intensity. The choice of ion polarity depends somewhat on the choice of the matrix. For 3-hpa (see below) the positive ion mode is usually preferred because doubly charged ions are less abundant in the positive ion mode. Successful UV-MALDI analysis with solid-state matrices requires an undisturbed crystallization of the sample on the target. Buffers, detergents, and other additives, such as glycerol, interfere with this crystallization even at low concentrations. Therefore, ammonium buffers should replace phosphate and similar buffers in the molecular biological procedures for sample generation. Detergents should be avoided, or non-ionic detergents should be used, if necessary. Proteins, such as polymerases, exo- or endonucleases or restriction enzymes, in the final sample can partially or fully suppress the oligonucleotide signals in the spectrum because of their higher proton affinity. Templates from polymerase chain reaction (PCR) or other enzymatic reactions may also cause problems. All these components need to be removed by precipitation or other suitable methods. Several companies market commercial purification kits. In so-called “homogeneous assays” (see below) a sample dilution may also decrease their concentration below a critical value. Sample purification is even more critical in ESI-MS. A comparison of the efficacy of different purification procedures has recently been published by Null et al.5
SAMPLE PREPARATION
FOR
MALDI MASS SPECTROMETRY
The proper choice of matrix is of utmost importance for a successful MALDI-MS of oligonucleotides. 3-Hydroxypicolinicacid (3-hpa) has proved to be the matrix of choice for the UV-MALDI-MS of DNA at the commonly used 337 nm wavelength of the nitrogen laser or the 353 nm of the frequency tripled Nd:YAG laser, mainly because it induces the least fragmentation of analyte ions. Unless very special precautions are taken, only signals of the single strands are recorded in MALDI spectra. It is assumed that the acidity of this matrix leads to a separation of doublestranded species already in solution. Interestingly, acidic base hydrolysis is observed only rarely, provided that the solvent is evaporated off immediately after mixing analyte and matrix. Once in the solid state, the samples remain stable for prolonged times if kept in a strictly dry atmosphere. Compared to the α-cyano-4-hydroxy-cinnamic acid matrix, frequently used for peptide analysis, 3-hpa has a less favorable crystallization behavior, forming rather heterogeneous samples with a pronounced statistical morphology and a separation of the analytes into so called sweet spots. Such sweet spots describe areas of a given sample, which turn out to give good spectra. The cause for this heterogeneity and why some areas give much better results than others are largely unknown. Fractionation of analytes into different areas may contribute, but is certainly not the only reason. The former limits mass accuracy in linear time-of-flight (lin-TOF) analyzers to typically a few mass units. The latter requires probing of a fair number of different areas of the sample in order to obtain spectra that truthfully reflect the analyte content and have a good signal-to-noise ratio. This is particularly worrisome in mixture analysis where a truthful representation of all components in the mixture is required (see “quantification” below). A very sizable improvement in the influence of this sample morphology has been achieved through the preparation
88
Analytical Techniques in DNA Sequencing
of microsample from a few nanoliters of matrix and analyte solutions, yielding samples only a few hundred micrometers in size;6 the standard dried droplet method, in comparison, uses a few microliters of matrix and sample, resulting in millimeter size preparations. For high-throughput analysis such nanoliter samples are best prepared on chips a few centimeters in size, which accommodate 96 or 384 samples in a microtiter plate format.7 These chips are surface-modified with hydrophilic plaques in a hydrophobic surrounding to reproducibly anchor the samples in predetermined locations, as has been described by Schürenberg et al.8 for microtiterplate size sample plates. Several other matrices have been tested for the analysis of oligonucleotides with mixed success. Exception may be a mixture of 2,3,4-, 2,4,6-trihydroxyacetophenone (THAP) (both 0.2 M ) and diammoniumcitrate (0.3 M ) in a 1:1:2 ratio (v:v) for the analysis of RNA-oligomers and 6-aza-2-thiothymine (ATT) for the detection of ds-DNA9 and of DNA/protein non-covalent complexes in research applications.
ION FRAGMENTATION Quite in contrast to the situation in a physiological solution, ions of DNA in the gas phase are much more prone to fragmentation than proteins/peptides. This abundant fragmentation severely limits the accessible mass range and size of analytes at least in UV-MALDI-MS. Routine application of MALDI-MS for oligonucleotide analysis has therefore required and induced the development of suitable molecular assays, which allow us to obtain the information of interest from oligomers of limited size, such as the analytes described below. High-throughput analysis is currently limited to oligomers of less than approximately 50 bases in length. Fragmentation is another reason, which has so far prevented applications of MALDI-MS to de novo sequencing by the Sanger or similar approaches. The cause for this lability of DNA has been discussed controversially in the literature over the years. Two recent publications showed by H/D-exchange, postsource-decay (PSD) experiments that the fragmentation is initiated by facile loss of any of the high-proton-affinity A, C, and G bases, induced by a weakening of the N-glycosidic bond after protonation of the base.10,11 Surprisingly, this is even the case in negative ion mode where the base protonation results from a zwitterion formation of these bases with their 5′-neighboring phosphate groups. Following base loss, the DNA-strand becomes destabilized, which results in a series of zipper-type fragmentations of the backbone and a total loss of information on the original strand. Whereas base losses are also observed “prompt,” i.e., on a timescale below ∼100 ns, most of the following fragmentation occurs metastably on a micro- to millisecond timescale. Many attempts have been reported to limit the fragmentation by chemical modifications. These modifications have involved the bases (e.g., 7-deaza-A and G), the ribose (e.g., 2′-F) and the phosphate backbone. None of these modifications has found large-scale applications mostly because they all more or less strongly compromise the molecular biology of the common sample generation procedures. The only exception is alkylation of the backbone as the very last step of sample generation, which is usually combined with charge tagging of the oligomers.12 Although very successful
Analysis of Nucleic Acids by Mass Spectrometry
89
in stabilizing the ions, a reproducibly complete alkylation is restricted to oligomers of at most 15 bases in length. An interesting aspect of the fragmentation mechanism is the inherently higher stability of RNA relative to DNA: the 2′-OH group stabilizes the N-glycosidic bond and thereby essentially prevents base loss. Recently, assays comprising transcription and analysis of RNA strands have been reported13 (see below). IR-MALDI with infrared wavelengths in the 3-µm region exhibits a dramatically reduced fragmentation. Accordingly, ions of single-stranded restriction enzyme fragments up to 2 kb in length have been recorded with a glycerol matrix.14 Intense matrix adduct formation unfortunately limits the mass resolution in these spectra to values of 100 or less, which has, so far, prevented routine application of this technique. ESI is also inherently softer than MALDI. Highly charged ions of plasmid and phage DNA of more than 10 kb have been generated by ESI. Exact determination of the charge state is difficult in these cases, limiting the accuracy of mass determination to less than ±10%. This work is reviewed in Reference 2.
INSTRUMENTATION Fragmentation also strongly influences the choice of mass analyzers suitable for DNA analysis. Lin-TOF analyzers are almost exclusively used in conjunction with UV-MALDI sources. Ions decaying in the field free drift tube after the ∼1 µs time of (delayed extraction) acceleration in the source will continue to travel at essentially the same speed as the parent ion and arrive at the detector concurrently with it, thus contributing to the signal of interest. Mass resolutions of 500 to 1000 are routinely achieved in such instruments. Reflectron-TOF (ref-TOF) analyzers are not suitable, because of the mass dispersion of the fragments in the reflector field, except for the identification of specific fragments by PSD analysis in a research mode. All other standard mass analyzers such as ion traps (IT) and Fourier-transform ion-cyclotronresonance (FT-ICR) analyzers require milliseconds to seconds for the analysis, which interfere with the ion lifetimes. Recently, hybrid quadrupole-TOF analyzers with an orthogonal ion extraction into the ref-TOF analyzer have been marketed by several companies (Q-TOF: Micromass Ltd, Manchester, U.K. or Q-star: MDS Sciex, Inc., Toronto, Canada). These instruments offer the option of injecting the MALDI ions into a region of elevated pressure at typically 1 to 100 mbar, where they become thermalized by collisions with the neutral gas. This thermalization dramatically reduces metastable fragmentation and permits the analysis even of oligonucleotide ions in the following ref-TOF. The first results of the analysis of DNA fragments with such instruments were very promising.15 A combination of such thermalization MALDI-ion sources with ion traps and FT-ICR also holds some promise and has been successfully tested for other analytes of similar lability.16 FT-ICR analyzers have been used very successfully for the analysis of oligonucleotides in combination with ESI sources. The very high mass resolution of these analyzers permits the unambiguous identification of the signals of different charge state even for rather complex mixtures of analytes in a given sample. A good example for such an application has recently been described by Null et al.17 The stringent sample purification requirements and the complexity and analytical speed
90
Analytical Techniques in DNA Sequencing
of FT-ICR instruments somewhat limit this approach in routine and high-throughput analysis of oligonucleotides.
QUANTIFICATION
AND
MIXTURE ANALYSIS
Absolute quantification is not an option for most MS applications and even relative quantification requires great care. Fortunately, even oligonucleotides of different mixed sequence desorb and ionize with at least comparable efficiencies in a MALDI source, except for a general decrease of signal intensity with increasing size of the oligomer. This decrease can be attributed to the decreasing yield of ion formation as well as to the increasing fragmentation. Signals of oligonucleotides of nearby masses in the same spectrum can, therefore, be compared quantitatively with a precision of a few percent. Algorithms, which account for the decrease of signal with size and the minor influence of the base content, can also be developed. The main limitation for quantification is the dispersion and disproportionation of analytes in the matrix preparation discussed above. Quantification of 3-hpa UV-MALDI spectra, therefore, strictly requires accumulation of a large enough number of spectra from different locations of a given preparation. Improvements in sample preparation toward more homogeneous samples would be highly desirable for analyses requiring quantification. Sample disproportionation can also be a problem in mixture analysis. Again, spectra obtained from one given location of the preparation may not be representative for the full content of analytes in the sample. This can be particularly worrisome for the analysis of primer extension products for the analysis of single nucleotide polymorphisms (SNPs), where a heterozygote may be classified as homozygous because of analyte disproportionation. Analysis of mixtures with a very large number of different oligonucleotides such as would be encountered in a Sanger ladder or an exo- or endonuclease digest may give rise to another problem. It is generally assumed that the total charge available for the formation of ions in a given desorption event is limited and largely independent of the number of different analytes in the mixture. If this charge is distributed among an increasing number of ions of different mass, the signal-to-noise ratio of each single signal will decrease. The limited dynamic range of typically 8 bit of the ion detection may also introduce a limitation, if signals of a much wider range of intensities occur in the spectrum.
ROLE OF MALDI-TOF-MS IN HIGH-THROUGHPUT SEQUENCE ANALYSIS APPLICATIONS Efficient sequence analysis of whole genomes of individual species and organisms as well as efficient sequence comparison of the information contained therein is still one of the major tasks to advance our understanding in fields such as biology, medicine, or evolution. The fulfillment of these tasks demanded technological developments in the field of DNA sequence analysis: first, methods for large-scale de novo sequencing were (and still are) required, which allow for timely and cost-effective analysis of megabase to gigabase DNA stretches (generation of reference sequences); second, methods for large-scale comparative sequence analysis, which allow for fast
Analysis of Nucleic Acids by Mass Spectrometry
91
but accurate elucidation of inter- and intraspecies genetic variation and heterogeneity (exploration of genetic markers); and third, methods that can efficiently score very large numbers of genetic markers in selected populations to determine genotypephenotype correlations.
MALDI-TOF-MS–BASED DNA SEQUENCING
AND
RESEQUENCING
In the early phase of the Human Genome Project, MS, and MALDI-TOF-MS in particular, received attention as an alternative method for separation and detection of Sanger sequencing ladders.18 The basic underlying idea was to improve the speed and accuracy of the sequence analysis process. MALDI-TOF-MS offered an unparalleled speed in signal acquisition (microseconds in TOF systems opposed to hours for conventional gel-electrophoresis-based systems), a higher accuracy due to analysis of an intrinsic molecule property, the molecular mass, and the potential for a high degree of automation. Several biochemical schemes had then been developed, which generated DNA sequencing ladders of sufficient yield and purity to suit the specific requirements for the analysis by MALDI-TOF-MS.19–22 Following the concept of conventional dideoxy sequencing, the nested set of truncated sequences originating from a primer can, in principle, be analyzed by MALDI-TOF-MS and the mass difference between the DNA fragments can be used to calculate the nucleotide sequence. However, because of the nearly exponential decay in sensitivity of MALDI-TOF-MS with increasing mass of the DNA fragments, as described in earlier paragraphs of this chapter, the read length of this approach was rather limited and hardly competitive with fluorescence-based dideoxy sequencing. Despite very promising results for solid-phase-based sequencing and cycle sequencing, the 100 bp barrier was never overcome on a routine basis. In addition to sensitivity issues limiting the overall read length, the mass resolution of conventional axial-TOF instruments was in some cases insufficient for very accurate sequence determination. Insufficient discrimination between polymerase pausing signals generated by secondary structures of the template and “real” termination signals, moreover, significantly hamper sequence analysis in the higher mass range. Sensitivity as well as mass resolution and mass accuracy issues in the higher mass range have all contributed to the fact that analysis of dideoxy sequencing ladders by MALDI-TOF-MS has not yet been implemented in high-throughput sequencing applications. For all these reasons, early advances in the use of MS for the analysis of oligonucleotides have, therefore, occurred for the analysis of single nucleotide polymorphisms rather than sequencing. These applications are discussed further below. Recently, however, a new scheme for sequence analysis by MALDI-TOF-MS has been introduced.13 Rather than using a primer extension–based method, which yields a ladder of DNA fragments with increasing sizes starting from the primer length and thus rapidly interferes with the current capabilities of MALDI-MS, this scheme relies on the generation of rather short base-specific fragments from a given nucleic acid amplificate, in principle similar to peptide mapping in protein identification. It uses base-specific RNases for template digestion, followed by an analysis of the resulting cleavage products by MS.23
92
Analytical Techniques in DNA Sequencing
Base-specific cleavage of nucleic acids represents a paradigm shift in sequencing by MS. The principle resembles more closely the original approach of Maxam and Gilbert for DNA sequencing.24 It is, however, not a de novo sequencing method and rather represents identification or resequencing, where an experimentally determined sequence is cross-compared to a known reference sequence. In base-specific cleavage, a single-stranded copy of a target sequence is generated and cleaved to completion in four separate base-specific reactions. Each reaction reduces the original sequence to a set of oligonucleotides, which is readily separated and analyzed by MALDI-TOF-MS. To each mass signal of a base-specific cleavage reaction, a set of compomers can be assigned. The sequence can be reconstructed from this set of compomers by combining the information of all four cleavage reactions and comparing it to a predicted set of mass signals as provided for an in silico digest of the reference sequence. Sequence changes between the reference sequence and the experimentally analyzed sample sequence have a profound impact on the mass signal pattern. A heterozygous sequence change can generate up to five observations in the mass signal patterns: it can add or remove a cleavage site in one or more cleavage reactions as well as shift the mass of single products by the mass difference between exchanged nucleotides. For heterozygous samples, additional mass signals appear in the spectra. A homozygous sequence change might even provide up to 10 observations, because not only additional but also missing signals can be used to detect, identify, and locate the sequence change. Figure 5.1 illustrates how the principle would relate to the detection of a G-C sequence change in a target region. Assuming that the region of interest is analyzed after a C- and a T-specific cleavage of both, the forward and the reverse strand (equivalent to four base-specific cleavages), the sequence change from G (as the reference nucleotide) to C would generate five additional mass signals for a heterozygous sample. In the T-specific cleavage (forward reaction), one oligonucleotide resulting from the cleavage would shift by 40 Da (as the mass difference between C and G). In C-specific cleavage (forward), the sequence change would generate a new cleavage site and would thus split the original 8-mer fragment into a 3-mer and a 5-mer fragment. Supporting information would then be generated in the analysis from the reverse strand. Here again, the T-specific cleavage would show one fragment shifted by the mass difference between C and G, and for the C-specific reaction, a cleavage site would be removed, generating a 12-mer fragment instead of the original 10-mer fragment. In most cases, the combined observations of the four reactions allows for an unambiguous identification and localization of the sequence change. This scheme has the limitation that some cleavage information is lost in either the low or the high mass range or by overlapping cleavage products. With increasing length of the target region (from 200 bp upward to 1 kb), the mono-, di-, tri-, and even sometimes tetra-nucleotides are completely non-informative due to many fragments of nominally equal mass. Additionally, their detection is often hindered by strong matrix signals in the low mass range. Longer target sequence regions increase the total number of cleavage products and thereby cause more cleavage products to overlap in mass. This reduces the number of possible observations based on either additional or missing signals. Thus, the ability to locate a sequence change exactly is a more likely limitation than sensitivity and mass accuracy for long fragments,
Analysis of Nucleic Acids by Mass Spectrometry
93
FIGURE 5.1 Allele-specific mass signal patterns generated by base-specific cleavage. Displayed is a hypothetical sequence carrying a G-C polymorphism. Assuming two transcription reactions of the forward and two from the reverse strand, both followed by either T- or Cspecific cleavage, the resulting cleavage pattern shows distinct changes. The T-specific cleavage of the forward transcript yields a new fragment with 40-Da mass difference to the reference fragment when a G-C substitution is present. The substitution does not change the cleavage sites, but leads to fragments with the same length, but different composition; hence, a mass difference can be observed. In the C-specific cleavage, the same substitution introduces a new cleavage site and thus yields two new fragments of 3- and 5-nucleotide length, respectively, as opposed to the single 8-mer fragment generated by the reference. Supplementary information is generated in the reverse transcription and cleavage reactions. Again, the T-specific cleavage leads to a new fragment of same length but different composition. The compositional difference between C and G yields a 40-Da mass difference. The substitution removes a cleavage site for C-specific cleavage and generates a new fragment that is two nucleotides longer compared to the reference cleavage pattern. Combining the information contained in the four cleavage reactions, five additional mass signals can be observed in a sample heterozygous for the respective sequence change.
as encountered in the mass spectrometry of sequence ladders. An initial simulation of arbitrarily chosen 500 bp amplicons in the human genome revealed that about 90% of all theoretically possible sequence changes could be detected, characterized, and localized. An additional 10% can still be detected and characterized, leaving a fraction of nondetectable sequence changes below 1% (P. Stanssens, Methexis Genomics, personal communication, 2002). A way to further improve these numbers, especially for even longer amplicons, would be the additional evaluation of the (properly normalized) signal intensities or peak areas. This approach would enlarge the observations based on additional and missing signals by supporting observations based on significant changes in single peak intensities. The success of such an approach will largely depend on the reproducibility of overall signal-to-noise ratios between spectra and between samples, a challenge that is closely related to sample preparation and analyte homogeneity. Several approaches have been developed that allow for the generation of such base-specific cleavage patterns.25–27 Among these, transcription of the PCR amplicons into RNA prior to base-specific cleavage appears most promising, because the
94
Analytical Techniques in DNA Sequencing
transcription process further amplifies the number of molecules available for mass spectrometric analysis and generates single-stranded templates, thereby eliminating complicated means of generating single-stranded DNA molecules from the PCR product. Moreover, RNA is more stable under MALDI-TOF-MS conditions, as discussed above. The technique for a transcription-based approach is illustrated in Figure 5.2. PCR is performed with a primer pair carrying two different promoters at their 5′ positions. Following PCR and deactivation of the deoxy-NTPs by dephosphorylation, RNA polymerase and ribonucleotides are added to the reaction mixture. The RNA transcript is then cleaved by a base-specific RNase, and the resulting cleavage products are purified and conditioned for subsequent analysis by MALDI-TOF-MS. Typical mass spectra obtained from forward and reverse transcriptions of a 400-bp amplicon followed by G-specific cleavage with RNase T1 are depicted in Figure 5.3. The list of potential applications for base-specific cleavage followed by mass spectrometric analysis is widespread: it ranges from pathogen-typing and SNP discovery to the analysis of methylation patterns or mutation screening. Even the
FIGURE 5.2 Process flow for base-specific cleavage by RNA transcription. The target region is amplified with PCR primer carrying promoter tags. The PCR product is subsequently transcribed into a single-stranded RNA molecule, which then is cleaved base specifically by an RNase. The resulting cleavage pattern is analyzed by MALDI-TOF-MS. Comparison of an in silico reference sequence-derived cleavage pattern with the experimental data allows for sequence validation and detection of sequence changes.
Analysis of Nucleic Acids by Mass Spectrometry
2000
3000
4000
5000
6000
7000
95
8000
1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000
FIGURE 5.3 Representative MALDI-TOF-MS spectra of G-specific cleavage patterns generated by RNase T1 treatment of a 500-mer transcript. Both forward and reverse transcription was performed. The analyzed mass window usually ranges from 1000 to 9000 Da. Signals below 1000 Da are suppressed to minimize interfering matrix signals. Mass signals over 9000 Da usually have insufficient signal-to-noise ratios to contribute faithfully to the analysis.
large-scale characterization of cDNAs and their alternative splice variants might be approached by base-specific cleavage. All these applications comprise large-scale comparative sequence analysis. They are a next cornerstone in the attempt to further elucidate the genetic code and its individual variations. As shown again later, the advantage of MALDI-TOF-MS in comparative sequence analysis rests on two important features: speed of signal acquisition and accuracy. The real-time spectra acquisition and analysis of a single sample is today routinely achieved in about 1 s when chip arrays are used as launching pads. This holds for base-specific cleavage patterns as well. Even if more than just one sum spectrum is acquired for a given sample, the acquisition can be completed in about 5 s at a laser pulse repetition rate of 20 Hz. Considering four base-specific cleavage reactions and an average amplicon length of 500 bp (4 × 5 s = 20 s/500 bp), a single MALDI-TOF mass spectrometer can easily scan 1 million to 2 million base pairs per day. This compares favorably with state-of-the-art sequencing equipment. Automated analysis of this amount of data is a challenging task, especially when single base changes have to be detected with high reliability. The combination of MS with base-specific cleavage offers some significant advantages in that respect: redundancy of information and, thereby, the reliability of the result is strongly enhanced, because the identification of a polymorphism or mutation is based on one or multiple observations, which occur at separate and distinct positions of one or more mass spectra. This is in strong contrast to standard fluorescence-based Sanger sequencing,
96
Analytical Techniques in DNA Sequencing
where sequence changes have to be identified by multiple bands/colors occurring at the exact same position of the electropherogram. Moreover, the measured fragment mass is an inherent property of the analyte, in contrast to the fluorescence of tagged nucleotides.
MALDI-TOF-MS–BASED SNP SCORING
AND
MUTATION ANALYSIS
The continuing progress of genome projects28,29 has provided the basis for identification of a very large and still increasing set of DNA markers. DNA markers are stretches of inheritable polymorphic nucleotide sequence. They proved useful in assessing inter- and intraspecies specific variations and help to understand the genetic contributions to phenotypic expression of an organism as well as its differences. DNA markers are widely used in a diverse set of applications, which include criminal suspect identification, linkage analysis, pharmacogenomics, or routine clinical diagnostics of mutations, suspected or known to cause a given disease, to name just a few. Genetic marker analysis evolved through different stages. It first made use of restriction fragment length polymorphisms (RFLPs), then microsatellites (short tandem repeats, or STRs) and, most recently, single nucleotide polymorphisms (SNPs). Prevalence for the use of one or the other type of marker in genetic mapping and other applications was, and still is, largely a question of their availability, information content, and the availability of a suitable technology. SNPs, the “youngest” member of the family of genetic markers, occur with a high frequency in most genomes and thus have a tremendous impact on the generation of high-resolution genetic maps. Studies performed on human genomic samples lead to an estimate of a frequency of about 1 SNP for every 1000 bp, with even higher frequencies suggested for certain gene regions.30 Diversity in other organisms, like plants, is expected to be five to seven times larger.31 Because of the simplicity of their bi-allelic nature, SNPs offer a high potential for process automation and fully automated data analysis, a key aspect when entering high-throughput genetic analysis projects. The efforts to explore the genetic basis of complex inherited diseases or disease predisposition have generated an increasing demand for high-throughput marker analysis.32 Many further research areas, like plant and animal genomics, require the large-scale identification of quantitative trait loci for molecular breeding.33 These efforts have in common that candidate or target genes/gene regions need be identified. To accomplish this task, whole genome association or linkage disequilibria studies in large populations have to be performed. The approaches use either large STR or SNP marker sets or a combination of both.34–36 Upon identification of candidate gene regions, further validation using a particular subset of even more densely spaced markers in affected and unaffected individual samples may be required, especially because functional allelic variants need to be explored to understand genotype-to-phenotype correlations. To illustrate the experimental workload of such approaches, consider the scoring of about 300,000 genome-wide distributed SNPs to deduce the association of particular genomic regions in a polygenic disease. For a statistically significant association, about 1000 individuals need to be analyzed for the complete set of
Analysis of Nucleic Acids by Mass Spectrometry
97
300,000 SNPs, totaling to 3 × 108 data points to be acquired. Projects of this size can only be performed with reasonable time and cost using technologies with a high enough rate of data point acquisition at low cost. High reliability and accuracy of the technology are of prime importance. Both are required to avoid any manual interference for data interpretation, a crucial factor in high-throughput applications. Furthermore, both influence the required sample size, often a decisive limitation, where the number of diseased individuals is limited. Many different platforms have been developed promising to fulfill the needs of current and future SNP scoring. Among them, MALDI-TOF-MS–based systems have gained significant attention due to their accuracy, speed, degree of automation, and their low cost per assay. Considering for example the estimated 3 to 5 M SNPs in the human genome, assay design, flexibility, and ease of assay implementation become further important aspects for a sustainable typing platform. Initially, MALDI-TOF-MS–based DNA analysis focused on the detection of PCR products associated with disease identification.37 The analysis of mutations in the cystic fibrosis gene is one such example, where the molecular mass of the detected PCR product indicates the presence or deletion of codon 508. The identification of mutations by MALDI-TOF-MS was also exemplified using restriction endonuclease digests,38 ligase chain reaction, and hybridization with PNA probes.39,40 All these experiments proved the general feasibility of MS in DNA analysis, but they required skillful scientists to acquire the spectra in a nonroutine environment; time-consuming hunting for so-called sweet spots of MALDI matrix preparations was necessary to obtain data with good signal-to-noise ratio and high resolution. Most assays and assay formats required optimization to obtain a minimum signalto-noise ratio and mass resolution. Additionally, sample preparation techniques were not applied in medium- to high-throughput mode. The development of generic methods for the analysis of polymorphisms and mutations was another cornerstone in the development of MALDI-TOF-MS to a highthroughput genotyping platform. Primer extension methods are such a generic scheme, which produce diagnostic DNA fragments of suitable length for analysis by MALDI-TOF-MS. The general principle is depicted in Figure 5.4. The target region carrying the polymorphism or mutation is first amplified by PCR. In a subsequent reaction, a primer is annealed adjacent to the polymorphic site and is terminated allele-specifically upon addition of a DNA polymerase and a suitable nucleotide mix. Termination products are analyzed by MALDI-TOF-MS and the obtained molecular masses are used to assign the corresponding genotype information. Several modifications of this basic scheme have been described in the literature. It had been introduced originally as the primer oligo base extension (PROBE) assay.41 PROBE was a solid-phase assay. Amplification was performed with one biotinylated primer, which allowed for an immobilization of the PCR product on streptavidincoated solid support. Following denaturation, the detection primer was annealed directly adjacent to the polymorphic region. Extension is initiated by addition of a DNA polymerase and a nucleotide mix, with at least one natural nucleotide (dNTP) replaced by its corresponding terminator (ddNTP). As depicted in Figure 5.4, this leads to an allele-specific termination and the termination products differ in mass by at least one nucleotide.
98
Analytical Techniques in DNA Sequencing
a.i 1900 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 6000
8000
10000
12000
m/z
FIGURE 5.4 Principle of primer extension–based analysis of SNPs. Following amplification, a primer is annealed adjacent to the polymorphism. The extension is terminated allele-specific. The products are analyzed by MALDI-TOF-MS and unambiguous assignment of the alleles is performed based on the molecular weight information.
With a careful choice of the termination mix, this reaction allows identification of virtually any kind of single mutations or polymorphisms. In addition, polymerase pausing artifacts, often occurring in complicated sequence contexts, can be discriminated from real alleles. Pausing events lead to primer extension products not terminated by incorporation of a dideoxynucleotide. Thus, the corresponding products show mass signals of at least 16 Da difference to the allele specific products. Again, careful design of the assay, using, for example, three terminating nucleotides (ddNTPs), increases the mass difference between allele-specific termination products and unwanted polymerase artifacts and avoids misinterpretation of mass signals even in routine high-throughput environments. The use of paramagnetic particles in high-throughput processes soon became a significant bottleneck. It required complicated pipetting and handling steps, hindered miniaturization, and added significant costs. Thus, alternative approaches were introduced.
Analysis of Nucleic Acids by Mass Spectrometry
99
The PinPoint™ assay, for example, used reversed-phase columns in the form of ZipTips (Millipore) for the purification of extension products.42 ZipTips, however, required frequent replacement and showed a tendency to become clogged, a reason this purification approach did not comply with high-throughput processing. PinPoint also employed a nucleotide mix devoid of any elongators (dNTPs). The primer is only extended by one nucleotide and alleles are discriminated by the value of the mass difference between the four ddNTPs. This assay type increases the flexibility for the design of multiplexed assays, but also imposes the risk of poor discrimination between A and T alleles (only 9 Da mass difference) and between adduct signals (for example, sodium and potassium: 23 and 39 Da, respectively) and “real” alleles (mass difference T – G is 25 Da and C – G is 40 Da, respectively). A different approach was introduced with the GOOD assay.43 In contrast to the other two methods, this approach did not require any purification steps prior to mass spectrometric analysis. The extension reaction is performed with an oligonucleotide primer carrying α-S-dNMPs at the 3′ end and in the presence of α-S-ddNTPs. After the extension reaction, the unmodified 5′ end of the primer is removed by degradation with phosphodiesterase II. The remaining extended oligonucleotide is backbonealkylated with methyliodide, to suppress the otherwise abundant formation of multiple salts of monovalent and divalent cations and limit ion fragmentation, known to be initiated by zwitterion formation of the bases with their neighboring 5′phosphate group. Chemical charge-tagging of this molecule with either a single excess positive or negative charge allows the analysis of positive or negative ions from the crude solution with high sensitivity. Although this approach avoids purification steps, it increases the complexity of the genotyping process by adding several more reaction layers. A major drawback is also the use of the toxic methyliodide. To address these issues, a modification of the original protocol has been introduced recently, which makes use of methylphosphonate primers.44 The methyl groups are already introduced at the stage of primer synthesis by the use of respective phosphoamidites so that no further postextension modification except the phosphodiesterase treatment is required. Commonly used DNA polymerases did not extend methylphosphonate primer efficiently, but the group also introduced a new DNA polymerase, which seems to eliminate this issue. The accuracy and efficiency of mass spectrometric separation and detection of primer extension products have recently been commercialized as an integrated system for SNP analysis.45 Original solid-phase formats have been replaced by homogeneous single-tube assays, which are combined with the simple addition of ion-exchange resin beads for conditioning of the extension products prior to mass spectrometric analysis. To fulfill the demands of high-throughput genotyping, parallel processing in 384-well formats has been combined with miniaturized sample preparation on chip arrays as launching pads for the mass spectrometry. Advanced nanoliquid handling based on piezoelectric pipettes or pin tools allows the preparation of as little as 15 nl matrix or sample on surface-modified silicon chips. MALDI-TOF-MS benefits from this miniaturization in that crystal formation is much more homogeneous, allowing fully automated scanning with
100
Analytical Techniques in DNA Sequencing
only a few laser shots per sample. Currently, as many as 3840 samples can be analyzed in unattended mode, with an average data acquisition time of only 1.5 s per sample. This allows a single mass spectrometer to acquire up to 50,000 mass spectra per day. Further increases in throughput can be achieved by multiplexing of the SNP assay. The analysis of a single primer extension reaction requires only a fraction of the accessible mass window. Figure 5.5 depicts a mass spectrum of a tetraplexed primer extension assay, which shows that intercalation of the extension products allows a more efficient use of the available mass window. Through intelligent assay design, even higher multitudes of primer extension reactions can be combined in a single reaction or detection. Multiplexing of as many as 12 SNPs assays has already been described,46 although the current level of generically developed multiplexes is in the range of 6- to 8-plexes. The main factor influencing this number is the ability to perform multiplexed amplification of the target loci in the initial PCR without major deviations in PCR yield between the respective products. The use of a genotyping platform in high-throughput environments also depends strongly on the bioinformatics capabilities. Large numbers of data sets must be automatically translated into genotype information without requirement for manual interference. Also, the assay design process and any required assay validation procedures need to be very efficient. Mass spectrometry meets both these requirements extremely well in that this technology determines directly an intrinsic molecule property, the molecular mass. Each of the primer extension products can only consist of the four natural dNTPs (dATP, dCTP, dGTP, and dTTP) as well as one or more of the terminators of the primer extension reactions (ddATP, ddCTP, ddGTP, and ddTTP).
6000.0
7000.0
8000.0
FIGURE 5.5 Multiplexed analysis of SNPs. Depicted is a MALDI-TOF mass spectrum of a 4-plex MassEXTEND reaction. The four sets of primer and primer extension products are marked with a number. 1P to 4P represent the positions of unextended primer. Primer extension efficiencies vary with the sequence context and length. In some cases no unextended primer is detectable (4P). Corresponding alleles are marked with an A. The respective DNA is homozygous for assays 1, 2, and 4 and heterozygous for assay 3.
Analysis of Nucleic Acids by Mass Spectrometry
101
Thus, any possible product can be precalculated and there is no need for complex algorithms to analyze the molecular mass information. Given the use of a suitable nucleotide mix, polymerase artifacts like pausing can be discriminated from “real” termination products by their molecular mass. These features have been combined in a computer-aided assay design tool, which allows the generation of large numbers of primer extension reactions for detection by MS in high-throughput mode. An interesting new application for MALDI-TOF-MS is the determination of allele frequencies by means of pooled DNA samples. Rather than analyzing the genotype of individual samples to determine the allele frequency in a given population, this approach uses DNA pools, which comprise equimolar amounts of up to several hundred individual DNAs. The DNA pool is subjected to amplification. Then the described primer extension reaction is performed. A careful quantitative analysis of the relative peak areas of the two alleles in the mass spectra allows us to estimate the respective allele frequency in the sample pool. Allele frequency data generated this way can be an important feature for current aims of high-throughput SNP scoring, i.e., large-scale SNP validation. Before use of any in silico identified SNP (isSNP) in genome screens or candidate gene approaches, there has to be some sort of validation for this potential marker with respect to the phenotype of interest: Is the isSNP a relevant polymorphism, or is it a sequencing artifact? In this respect, validation, for example, can be performed in ethnic pools. In addition, the use of pools could provide a way to filter large sets of SNPs for those candidates worthy of follow-up, without carrying the burden of individual genotyping for all these markers.47–49 Combining the described features of MS in automated assay design and highthroughput SNP scoring with the concept of sample pooling has recently been shown to allow the large-scale implementation of several thousand SNP assays within a period of only 1 month.50
CONCLUSIONS AND FUTURE PROSPECTS MALDI-TOF-MS has become a vital technology in current and emerging bioanalytical approaches. It plays a pivotal role in protein and carbohydrate analysis. Application of MALDI-TOF-MS to analysis of nucleic acids has also increased vastly in recent years. MALDI-TOF-MS combines core features, such as the speed of signal acquisition, determination of an analyte-specific inherent physical property, the molecular mass, a high accuracy, and a high degree of automation. These features enabled MALDI-TOF-MS to capture a leading position in the highthroughput analysis of genetic variations. As shown, the predominant application for MALDI-TOF-MS of nucleic acids is the analysis of SNPs and mutations in large-scale genetic studies. The determination of allele frequencies in DNA pools has been introduced recently and has found widespread use. Although the quantitative nature of MALDI has been a topic of debate in protein analysis, it was found that the area-under-the-curve ratios of allele-specific primer extension products provide an accurate estimate of the allele prevalence in a mixture of several individual genomic DNAs. This is mainly because nucleic acids are composed of only
102
Analytical Techniques in DNA Sequencing
four building blocks (dAMP, dCMP, dGMP, and dTMP) with very similar desorption characteristics compared to amino acids/peptides. Furthermore, miniaturization of the sample preparation in chip array formats decreased the variance caused by inhomogeneous crystallization. Primer extension–based MALDI-TOF-MS methods for genetic analysis not only have found widespread use in research laboratories; but they have also been perfected for industrial-scale processes when combined with suitable automation robotics and are now routinely used in high-throughput environments. Expansion of the portfolio of available molecular biological methods, such as the principle of base-specific cleavage, is a significant milestone, which allows a more generic use of MALDI-TOF-MS in the field of genomics. This approach is comparatively young and is not established to the same degree as the SNP scoring approaches presented. However, it exemplifies the prospects to keep MALDI-TOF-MS on board as a competitive technology in nucleic acid analysis. Currently, the envisioned future developments can be separated into three main categories: instrument developments, application developments, and sample generation/preparation. Multiplexed SNP analysis, as well as resequencing using base-specific cleavage, is starting to challenge the capabilities of current axial MALDI-TOF mass spectrometers. Mass accuracy, mass resolution, and sensitivity can become a limiting factor, when we attempt to fully exploit these applications on a biochemical basis. The dynamic range might be another concern relevant for those applications, where a minority of genetic information has to be detected in the presence of excess of wild-type information. Such applications include the detection of rare genetic variants in DNA pools or sample mixtures such as tumor biopsies. The combination of a MALDI ion source with a quadrupole-TOF (orthogonal [O]-TOF mass spectrometer) has a very high potential to meet the increased need in more complex applications of nucleic acid analysis. Extremely high-level multiplexing in SNP analysis, as well as de novo sequencing, requires the analysis of a very high density of nucleic acid fragment species within a defined mass window and thus will depend on higher-resolution advanced instrumentation. Further expansion of the application suite will be driven through improvements and redevelopment of biological/biochemical processes. In addition to SNP/mutation analysis by primer extension and SNP discovery by base-specific cleavage, new schemes can be envisioned for analysis of mRNA expression levels, the large-scale assessment of methylation patterns, screening of cDNA libraries, and analysis of microsatellites. This growing number of applications will help to establish MALDITOF-MS as one of the most versatile generic platforms in nucleic acid analysis. Last, further technology development must synchronize with current trends in miniaturization of sample handling and sample processing. Part of this trend is already implemented through the use of miniaturized chip arrays for MALDITOF-MS analysis as detailed above. As little as 10 nl of analyte is currently dispensed on these chip arrays in high-throughput settings. Considering that as much as 25 µl of analyte per well is currently produced in 384 microtiter plate formats and that only a 1/2500 fraction is actually used for analysis, the potential for process miniaturization without loss in performance becomes evident.
Analysis of Nucleic Acids by Mass Spectrometry
103
REFERENCES 1. K Strupat. Molecular weight determination of peptides and proteins by ESI- and MALDI-MS, in Methods in Enzymology, AL Burlingame, Ed., San Diego: Academic Press, in press. 2. J Gross, F Hillenkamp. Mass Spectrometry of Nucleic Acids. Encyclopedia of Analytical Chemistry: Applications, Theory and Instrumentation, Vol. 7, RA Meyers, Ed., New York: Wiley, 2000, 5022–5051. 3. U Pieles, W Zürcher, M Schär, HW Moser, Nucleic Acids Res 21(4):3191–3196, 1993. 4. E Nordhoff, Trends Anal Chem 15(6): 67–138, 1996. 5. AP Null, LT George, DC Muddiman, J Am Soc Mass Spectrom 13(4):338–344, 2002. 6. DP Little, TJ Cornish, MJ O’Donnell, A Braun, RJ Cotter, H. Koester, Anal Chem 69(229): 4540–4546, 1997. 7. DP Little, A Braun, MJ O’Donnell, H Koster. Mass spectrometry from miniaturized arrays for full comparative DNA analysis. Nat Med 3:1413–1416, 1997. 8. M Schürenberg, C Luebbert, H Eickhoff, M Kalkum, H Lehrach, E Nordhoff, Anal Chem 72(15):3436–3442, 2000. 9. P Lecchi, LK Pannell, J Am Soc Mass Spectrom 6(10):972–975, 1995. 10. J Gross, S Hahner, M Karas, A Leisner, F Lützenkirchen, E Nordhoff, J Schäfer, F Hillenkamp, J Am Soc Mass Spectrom 9:866–878, 1998. 11. J Gross, F Hillenkamp, KX Wan, ML Gross, J Am Soc Mass Spectrom 12:180–192, 2001. 12. S Sauer, D Lechner, K Berlin, C Plancon, A Heuerman, H. Lehrach, IG Gut, Nucleic Acids Res 28(23):e100/1–e100/6, 2001. 13. CP Rodi, B Darnhofer-Patel, P Stanssens, M Zabeau, D van den Boom. A strategy for rapid discovery of disease markers using the MassARRAY system. BioTechniques Suppl: 62–69, 2002. 14. S Berkenkamp, F Kirpekar, F Hillenkamp, Science 281:260–262, 1998. 15. S Berkenkamp, M Bromirski, W Ens, KG Standing, F Hillenkamp and A Loboda, Proceedings of the 49th ASMS Conference on Mass Spectrometry and Allied Topics, Chicago, IL, May 27–31, 2001. 16. PB O’Connor, E Mirgorodskaya, CE Costello, J Am Soc Mass Spectrom 13:402–407, 2002. 17. AP Null, JC Hannis, DC Muddiman, Anal Chem 73(18):4514–4521, 2001. 18. LM Smith. The future of DNA sequencing. Science 262:530–532, 1993. 19. H Koster, K Tang, DJ Fu, A Braun, D van den Boom, CL Smith, RJ Cotter, CR Cantor. A strategy for rapid and efficient DNA sequencing by mass spectrometry. Nat Biotechnol 14:1123–1128, 1996. 20. F Kirpekar, E Nordhoff, LK Larsen, K Krisitansen, P Roepstorff, F Hillenkamp. DNA sequence analysis by MALDI mass spectrometry. Nucleic Acids Res 26:2554–2559, 1998. 21. E Nordhoff, C Luebbert, G Thiele, V Heiser, H Lehrach. Rapid determination of short DNA sequence by the use of MALDI-MS. Nucleic Acids Res 28:E86, 2000. 22. NI Taranenko, SL Allman, VV Golovlev, NV Taranenko, NR Isola, CH Chen. Sequencing DNA using mass spectrometry for ladder detection. Nucleic Acids Res 26:2488–2490, 1998. 23. Hahner S, HC Ludemann, F Kirpekar, E Nordhoff, P Roepstorff, HJ Galla, F Hillenkamp. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI) of endonuclease digests of RNA. Nucleic Acids Res 25:1957–1964, 1997.
104
Analytical Techniques in DNA Sequencing
24. AM Maxam, W Gilbert. A new method for sequencing DNA. Proc Natl Acad Sci USA 74:560–564, 1977. 25. MS Shchepinov, MF Denissenko, KJ Smylie, RJ Worl, AL Leppin, CR Cantor, CP Rodi. Matrix-induced fragmentation of P3′-N5′ phophoramidate-containing DNA: high-throughput MALDI-TOF analysis of genomic sequence polymorphisms. Nucleic Acids Res 29:3864–3872, 2001. 26. F von Wintzingerode, S Bocker, C Schlotelburg, NH Chiu, N Storm, C Jurinke, CR Cantor, UB Gobel, D van den Boom. Base-specific fragmentation of amplified 16S rRNA genes analyzed by mass spectrometry: a tool for rapid bacterial identification. Proc Natl Acad Sci USA 99:7039–7044, 2002. 27. R Hartmer, N Storm, S Boecker, CP Rodi, F Hillenkamp, C Jurinke, D van den Boom. RNase T1 mediated base-specific cleavage and MALDI-TOF MS analysis for highthroughput comparative sequence analysis. Nucleic Acids Res 31:e47, 2003. 28. FS Collins, A Patrinos, E Jordan, A Chakravarti, R Gesteland, L Walters, and the members of DOE and NIH planning groups. New goals for the US human genome project. Science 282:682–689, 1998. 29. S Broder, JC Venter. Whole genomes: The foundation of new biology and medicine. Curr Opin Biotechnol 11:581–585, 2000. 30. DA Nickerson, SL Taylor, KM Weiss, AG Clark, RG Hutchinson, J Stengard, V Salomaa, E Vartiainen, E Boerwinkle, CF Sing. DNA sequence diversity in a 9.7-kb region of the human lipoprotein lipase gene. Nat Genet 19:233–240, 1998. 31. GL Sun, O Diaz, B Salomon, R von Bothmer. Genetic diversity in Elymus caninus as revealed by isozyme, RAPD, and microsatellite markers. Genome 42:420–431, 1999. 32. N Rich, K Merikangas. The future of genetic studies of complex human diseases. Science 273:1516–1517, 1996. 33. R Mott, CJ Talbot, MG Turii, AC Collins, J Flint. From the cover: a method for fine mapping quantitative trait loci in outbred animal stocks. Proc Natl Acad Sci USA 97:12649–12654, 2000. 34. GC Johnson, JA Todd. Strategies on complex disease mapping. Curr Opin Genet Dev 10:330–334, 2000. 35. L Kruglyak. Prospects for whole-genome linkage disequilibrium mapping of common disease genes. Nat Genet 22:139–144, 1999. 36. MK Halushka, JB Fan, K Bentley, L Hsie, N Shen, A Weder, R Cooper, R Lipshutz, A Chakravarti. Patterns of single-nucleotide polymorphisms in candidate genes for blood-pressure homeostasis. Nat Genet 22:239–247, 1999. 37. LY Chang, K Tang, M Schell, C Ringelberg, KJ Matteson, SL Allman, CH Chen. Detection of delta F508 mutation of the cystic fibrosis gene by matrix-assisted laser desorption/ionization mass spectrometry. Rapid Commun Mass Spectrom 9:772–774, 1995. 38. D Little, A Jacob, T Becker, A Braun, B Darnhofer-Demar, C Jurinke, D van den Boom, H Koster. Direct detection of synthetic and biologically generated doublestranded DNA by MALDI-TOF MS. Int J Mass Spectrom Ion Processes 169/170:133– 140, 1997. 39. C Jurinke, D van den Boom, A Jacob, K Tang, R Wörl, H Köster. Analysis of ligase chain reaction products via matrix-assisted laser desorption/ionization time-of-flightmass spectrometry. Anal Biochem 237:174–181, 1996. 40. PL Ross, K Lee, P Belgrader. Discrimination of single-nucleotide polymorphisms in human DNA using peptide nucleic acid probes detected by MALDI-TOF mass spectrometry. Anal Chem 69:4197–4202, 1997.
Analysis of Nucleic Acids by Mass Spectrometry
105
41. A Braun, D Little, H Köster. Detecting CFTR gene mutations by using primer oligo base extension and mass spectrometry. Clin Chem 43:1151–1158, 1997. 42. LA Haff, IP Smirnov. Single-nucleotide polymorphism identification assays using a thermostable DNA polymerase and delayed extraction MALDI-TOF mass spectrometry. Genome Res 7:378–388, 1997. 43. S Sauer, D Lechner, K Berlin, H Lehrach, JL Escary, N Fox, IG Gut. A novel procedure for efficient genotyping of single nucleotide polymorphisms. Nucleic Acids Res 28:E13, 2000. 44. S Sauer, DH Gelfand, F Boussicault, K Bauer, F Reichert, IG Gut. Facile method for automated genotyping of single nucleotide polymorphisms by mass spectrometry. Nucleic Acids Res 30:e22, 2002. 45. C Jurinke, D van den Boom, CR Cantor, H Koster. High-throughput genotyping based on MassARRAY. In Advances in Biochemical Engineering Biotechnology, J Hoheisel, Ed., Berlin: Springer-Verlag, 2002, 57–74. 46. P Ross, L Hall, I Smirnov, L Haff. High level multiplex genotyping by MALDI-TOF mass spectrometry. Nat Biotechnol 16:1347–1351, 1998. 47. M Werner, M Sych, N Herborn, T Illig, IR Konig, M Wjst. Large-scale determination of SNP allele frequencies in DNA pools using MALDI-TOF mass spectrometry. Hum Mutat 20:57–64, 2002. 48. A Bansal, D van den Boom, S Kammerer, C Honisch, G Adam, CR Cantor, P Kleyn, A Braun. Association testing by DNA pooling: An effective initial screen. Proc Natl Acad Sci USA 99:16871–16874, 2002. 49. KL Mohlke, MR Erdos, LJ Scott, TE Fingerlin, AU Jackson, K Silander, P Hollstein, M Boehnke, FS Collins. High-throughput screening for evidence of association by using mass spectrometry genotyping on DNA pools. Proc Natl Acad Sci USA 99:16928–16933, 2002. 50. KH Buetow, M Edmonson, R MacDonald, R Clifford, P Yip, J Kelley, DP Little, R Strausberg, H Koester, CR Cantor, A Braun. High-throughput development and characterization of a genomewide collection of gene-based single nucleotide polymorphism markers by chip-based matrix-assisted laser desorption/ionization timeof-flight mass spectrometry. Proc Natl Acad Sci USA 98:581–584, 2001.
the Single 6 Sequencing DNA Molecule Kenneth D. Weston and Markus Sauer CONTENTS The Idea of Single-Molecule DNA Sequencing ...................................................107 Detection and Identification of Single Molecules by Laser-Induced Fluorescence.........................................................................110 Identification of Single Molecules ........................................................................113 Incorporation and Degradation of Fluorescently Labeled Nucleotides by DNA Polymerases and Exonucleases ..........................................................121 Single-Molecule DNA Sequencing in Hydrodynamically Focused Sample Streams...................................................................................128 Single-Molecule DNA Sequencing in Microchannels and Submicrometer Capillaries .........................................................................134 Future Prospects ....................................................................................................146 References..............................................................................................................148
THE IDEA OF SINGLE-MOLECULE DNA SEQUENCING The U.S. Human Genome Project was initiated in 1990 and was originally planned to last 15 years. Effective resources and technological advances have substantially accelerated the determination of the sequence of all 3 × 109 base pairs (bp) that make up human DNA and the identification of the approximately 30,000 genes in human DNA. Several types of genome maps have already been completed, and the first analysis of the working draft of the entire human genome sequence was published in February 2001.1,2 Although Sanger’s enzymatic chain termination method proved to be very reliable, the limited read length of 100 ns) are inappropriate for single-molecule detection. The brightness, or detected fluorescence count rate, is particularly important because residence time of a diffusing molecule in the laser focus is very short (30 photon counts. Although the MLE algorithm is an extremely efficient and accurate method for determining lifetime values for fluorescence burst data, it is disadvantageous in several respects: First, the decay-time fitting procedure is time-consuming, which can be especially problematic when applying the algorithm to online data evaluation, where one would like to identify 100 or more molecules per second. Second, the fitting procedure and estimation of error rates become significantly more complicated for molecules that have a multiexponential fluorescence decay. Finally, the error of the fitting procedure itself adds to the overall error of correctly identifying the molecules. Recently, an advanced pattern-matching algorithm was presented for single-molecule identification based on fluorescence decay characteristics.73 This algorithm is applicable to arbitrary fluorescence decays and does not assume any knowledge of its underlying nature. Thus, no lifetime fitting or similar methods are involved. Moreover, the algorithm can be mathematically proved to be the best option for distinguishing molecules by their fluorescence decay behavior. The algorithm was applied to measured single-molecule data in solution for three different red-absorbing rhodamine derivatives with similar absorption and emission characteristics but slightly different fluorescence decay times of 3.85, 2.78, and 2.13 ns.73 A comparison with the error rates reported in References 35 and 46 through 52, which used the more conventional method of lifetime fitting with subsequent identification, showed that the advanced pattern-matching algorithm yields two to three times smaller error rates for similar differences in fluorescence lifetime and number of photons detected per molecule. A technique that will increase the identification accuracy of single molecules is a combined analysis of the fluorescence emission maxima and lifetimes of the dyes used. Recently, four different dyes embedded in a polymer film were identified with TCSPC spectrally resolved in two channels.74 In the following discussion, the emission maximum is obtained by splitting the emitted fluorescence with a dichroic beam splitter and detecting it at two independent detectors. The emission maximum is estimated using the ratio of the detected counts at the long-λ channel to the total counts and a careful analysis of the optical filters used in the detection path. Monte Carlo simulations showed that fewer than 500 photon counts are needed to assign an observed single molecule to one of four species with a confidence level higher than 99.9%. More recently, Sauer’s group75 undertook an experimental feasibility study with the goal of identifying freely diffusing single dye-labeled mononucleotide molecules in solution using both fluorescence emission maxima and lifetimes (Table 6.1). As shown in Table 6.1, the fluorescence emission maxima of the four conjugates differ between 644 nm (JA133-dUTP) and 692 nm (JA242-dUTP) with lifetimes differences between 1.32 ns (Cy5-dCTP) and 3.96 ns (JA133-dUTP).
120
Analytical Techniques in DNA Sequencing
TABLE 6.1 Ensemble and Single-Molecule (SM) Spectroscopic Characteristics (λabs, λem, τ, F2) of Fluorescently Labeled Nucleotides JA133-dUTP, JA169-dUTP, Cy5-dCTP, and JA242-dUTP (10–6 M) at 25°C in the Solvent Mixture (3% PVP, 20 mM Tris-borate buffer pH 8.4, 0.1% Tween 20, 30% glycerol)
JA133-dUTP JA169-dUTP Cy5-dCTP JA242-dUTP
λabs
λem
(nm)
(nm)
622 635 651 673
644 659 670 692
τ
τ(SM) (ns)
3.96 3.04 1.32 2.17
F2
(ns)
σ(τ)(exp) (ns)
F2 (SM)
σ((F2)exp
0.44 0.50 0.58 0.85
4.02 3.09 1.36 2.15
0.88 0.51 0.18 0.36
0.40 0.46 0.62 0.83
0.06 0.05 0.05 0.05
Note: The fractional intensity, F2, is the ratio of the signal measured at the long-λ (detector 2) to the total signal. The values in the table were predicted based on the emission spectra of the conjugates and the transmission curves of the beam splitters and bandpass filters in the measurement system.
A dichroic beam splitter was used to separate the fluorescence emission at ∼670 nm into the short-wavelength and long-wavelength fraction. As calculated from the ensemble spectra and the transmission of the filter set used, JA133-dUTP fluorescence bursts occur predominantly at the short-λ detector 1, whereas JA242-dUTP signals are detected almost only at the long-λ detector 2. Fluorescence bursts from JA169-dUTP molecules are detected with nearly equal efficiency at the two detectors, while Cy5dCTP bursts appear higher at the long-λ detector 2 (Figure 6.7). For statistical analysis, ∼4000 fluorescence bursts were measured for solutions of JA133-dUTP, JA169-dUTP, Cy5-dCTP, or JA242-dUTP. In Figure 6.8, the distribution of the fractional intensities, F2 (F2 = I1/[I1 + I2]), and fluorescence decay times calculated from the fluorescence photon counts registered at both detectors is shown. The resulting histograms were fit with Gaussian functions. Shown in Table 6.1, the mean single-molecule fluorescence lifetimes (τ(SM)) and spectral characteristics (F2) were in excellent agreement with the ensemble data. The symmetric shape of the decay rate and fractional intensity distributions signify spectroscopic homogeneity of the labeled mononucleotides in solution. Although the spectral distributions are relatively narrow for all four conjugates investigated, independent of the emission maxima, the experimental standard deviations of the calculated fluorescence decay times increases with decay time (Table 6.1). Figure 6.8 also shows the correlated fluorescence decay rate (kf = 1/τ(SM)) and fractional intensity (F2) data as two-dimensional histograms (scatter plots) with darker shades of gray indicating increasing number of events. Four distinct populations with symmetric shape are evident, corresponding to each of the species. Assuming independent distributions with respect to the fluorescence decay rate, kf , and the fractional intensity, F2, the data was sampled in a scatter plot ranging from 0 to 1.2 for kf on the x-axis and from 0 to 1 for F2 on the y-axis with a sampling value of 0.01. These scatter plots were fit using the superposition of two independent Gaussian distributions.
Sequencing the Single DNA Molecule
121
FIGURE 6.7 Time-dependent fluorescence signals recorded at the short-λ detector 1 (black) and long-λ detector 2 (gray, dotted line) from 10 –11 M solutions of (a) JA133-dUTP, (b) JA169dUTP, (c) Cy5-dCTP, and (d) JA242-dUTP (solvent: 3% PVP, 20 mM tris-borate buffer pH 8.4, 0.1% (v/v) Tween 20, 30% glycerin). The data were binned into 1-ms time intervals. The average laser power at the sample was 300 µW. (From DP Herten et al., Appl Phys B 71:765–771, 2001. With permission.)
This analysis yielded significantly higher classification probabilities for the four nucleotide conjugates. Applying the two-dimensional superposition of two independent Gaussians, three mononucleotide molecules were identified with a classification probability of ∼99%. This demonstrates that the use of spectrally resolved, time-correlated single-photon counting improves the accuracy of species identification and provides information about the heterogeneity or homogeneity of analyte solutions. The technique is a simple and sensitive tool and gives additional confidence that DNA sequencing at the single-molecule level will eventually become a reality.
INCORPORATION AND DEGRADATION OF FLUORESCENTLY LABELED NUCLEOTIDES BY DNA POLYMERASES AND EXONUCLEASES For the proposed method of single-molecule sequencing, labeling the bases of one strand of duplex DNA with distinctly coding fluorescent dyes is a necessary prerequisite. High-density labeling of DNA relies on the acceptance and proper incorporation of fluorescently labeled deoxynucleoside triphosphates (dNTPs) by
122
Analytical Techniques in DNA Sequencing
FIGURE 6.8 Scatter plot showing the correlated spectrally resolved (fractional intensity at the long-λ detector 2, F2) and time-resolved (fluorescence decay rate, kf = 1/τ(SM)) data and corresponding mean values and standard deviations of the superposition of two Gaussian fits. The data are presented as a two-dimensional histogram with darker shades of gray indicating increasing number of events. Histograms were constructed from separate experiments containing only one class of labeled mononucleotides. In each experiment, about 4000 fluorescence bursts with a burst size >50 photon counts were used. Average excitation power at the sample was 300 µW. (From DP Herten et al., Appl Phys B 71:765–771, 2001. With permission.)
the 5′→ 3′ polymerase activity. The incorporation of fluorescently labeled dNTPs by DNA polymerases into newly synthesized DNA, e.g., via polymerase chain reaction (PCR), is a standard technology of molecular biology. Most labeling protocols use the dNTPs attached to a fluorescent dye (via a spacer compound) only in mixtures with the respective natural dNTPs.76–79 In practice, most natural DNA polymerases have been found to discriminate against dye-labeled nucleotides; this may be because of steric hindrance at the active site of the polymerase due to the bulkiness of the label, and/or because the fluorescently labeled dNTPs typically have a net charge that differs from that of the natural substrates.76,77 Waggoner’s group80 studied the synthesis of labeled DNA probes by PCR using 60 mM dUTP attached to the fluorescent dyes Cy3 and Cy5 as a function of the linker length (Figure 6.9). Although the efficiency of incorporation of labeled
Sequencing the Single DNA Molecule
123
+ NH3
O
H2N -
-
SO 3
O3S + N
N
COO
-
O N H
HN O NH
-O
O
O
P
O P
O-
O O
O-
P
O O
N
O
O-
O
Rhodamine Green-5-dUTP
OH
HN O
O n
SO 3
-O 3S
n=0 Cy3-0L-dUTP n=2 Cy3-2L-dUTP
+ N
N
HN
-O
O
O
P
O P
O-
O-
O O
P
O O
N Cy5
O
O-
O OH
FIGURE 6.9 Molecular structures of fluorescently labeled nucleotides.
nucleotides increased with the length of the linker, the yield of labeled probe generated by PCR dropped significantly. In this study, as many as seven successive Cy3-2L-dUTPs could be incorporated. However, the fraction of complete chains in the product decreased below 20% after incorporation of only two neighboring labeled nucleotides (Cy3-0L-dUTP) with a short linker. Other groups reported a similar decrease in PCR yield.81,82 The higher incorporation efficiency of modified nucleotides with longer linkers can be explained by the reduced steric and/or electrostatic interactions between the polymerase and the fluorescent dye. These results imply that the interactions decrease with the distance between the active center of the polymerase and the incorporated fluorophores. In addition, it is assumed that dye-modified bases destabilize the double helix.80 During chain extension, the duplex structure may be stabilized with the help of the polymerase.83 If the duplex structure is destabilized only after the polymerase releases the DNA, it may be that chain extension cannot be resumed by another polymerase, even with longer extension times. Other studies have also found that the dye structure itself strongly influences the incorporation efficiency.84 Using Taq DNA polymerase for low-density labeling of DNA with various fluorescently labeled nucleotides, it has been shown that the incorporation efficiency of dye-dNTPs decreased in the following order: rhodamine-green-5-dUTP > tetramethylrhodamine-4-dUTP > Cy5-dCTP (Figure 6.9).84 Because of the various problems, a complete labeling of all four bases in long DNA strands, i.e., 100% substitution with fluorescent dNTPs, has yet not be achieved. An alternative approach is to synthesize the DNA to be sequenced with amino-modified nucleotides, e.g., aminoallyl-dUTP.
124
Analytical Techniques in DNA Sequencing
This DNA could be then be labeled with fluorescent dyes in a chemical postlabeling step. Unfortunately, quantitative chemical postlabeling of all aminoallyl groups with fluorescent dyes is complicated and difficult to control. Very recently, the enzymatic incorporation of modified dNTPs into growing DNA strands has been intensely studied using various reporter groups such as digoxigenin, biotin, fluorophores, or aliphatic side chains covalently attached to dUTP. Incorporation efficiencies were determined using various DNA polymerases.85 The linear primer-extension reactions were followed by polyacrylamide gel electrophoresis (PAGE) for high-resolution detection. It was possible to incorporate up to 40 successive bases with complete substitution of all four natural dNTPs using various modified nucleotides. The incorporation efficiency of dye-labeled nucleotides might be improved by using mutant polymerases. Some success in the complete labeling of DNA with fluorescently labeled nucleotides using a mesophilic, 3′→5′ exonuclease-deficient mutant of the T4 DNA polymerase has been reported.86,87 However, only a few mutant DNA polymerases have been identified that exhibit an increased capacity to incorporate modified nucleotides for the synthesis of long chains of complementary fluorophorelabeled DNA. Recently, the enzymatic incorporation of dNTPs by a new, thermostable, 3′→ 5′ exonuclease-deficient mutant of the Tgo DNA polymerase was studied.88 PCR based copying of 217-bp “natural” DNA in which fluorescent-dUTP was substituted completely for the normal dTTP was demonstrated using a relatively low nucleotide concentration of 50 µM.88 In contrast to other exonuclease-deficient B-type enzymes, this polymerase has a high thermostabilty, and offers the possibility of thermal cycling. The full-length replication and sequence integrity was demonstrated by preparative mobility-shift electrophoresis, reamplification in a subsequent PCR with normal dNTPs and resequencing. Fluorescently labeled nucleotide with 12 linker atoms between the base and the dye (rhodamine-green-5-dUTP, Figure 6.9) was base specifically incorporated in 82 to 88 positions out of 92 possible positions in a 217-bp DNA. The labeling efficiency of 0.89 to 0.96 indicates that nearly all of the possible incorporation sites of a thymine contained a fluorescently modified uracil, but that a fraction of the substrate analogue was not bearing fluorophores. The labeling efficiency of 0.89 to 0.96 indicates that nearly all the possible incorporation sites of a thymine contained a fluorescently modified uracil. Brakmann and Nieckchen89 used the well-documented power of direct evolution to identify mutant DNA polymerases that incorporate labeled nucleotides with high efficiency and retain a sufficient incorporation fidelity. A functional screening system allowed for the assessment of individual clones that show an increased acceptance of fluorescently labeled dNTPs. They discovered that a cloned natural polymerase, the unmodified exonuclease-deficient Klenow fragment of Escherichia coli DNA polymerase I, polymerized 55 template-instructed tetramethylrhodamine-4-dUTPs using an artificial (dA)55 template at a dUTP concentration of 25 mM. This result is quite surprising because 55 bp are expected to build up more than five turns of the DNA double helix, which should cause immense steric and electronic constraints due to the bulky rhodamine dyes. In a next step they applied the same enzyme to the analogous reaction with a natural primer-template with a length of 2700 bp (2.7 kb), substituting two of the natural substrates, dCTP and dTTP, by their
Sequencing the Single DNA Molecule
125
rhodamine labeled analogues, and they obtained a full-length product.90 Even more surprising was the finding that the exonuclease-deficient Klenow polymerase retained its replication fidelity (error rate < 1/10,000). From the biological point of view, it is unexpected that a growing primer-template containing bulky rhodamine dyes can be elongated with additional labeled nucleotides by a DNA polymerase that has evolved with the purpose of incorporating native unmodified nucleotides. The recently solved structure of bacteriophage T7 DNA polymerase shows that the enzyme’s active site forms contacts to the bases through numerous van der Waals interactions, and therefore, can precisely recognize the geometry of each base pair.91 Some experimental evidence exists that suggest that duplex DNA with one completely labeled strand undergoes a transition from a righthanded helix (B-DNA) to its left-handed form (Z-DNA).90 Obviously, some polymerases exhibit an extremely flexible catalytic cleft to surround a “swollen” DNA structure, and do not discriminate against the modified forms of duplex DNA. Furthermore, it has been shown that highly labeled DNA strands exhibit dramatically altered physical and chemical properties in comparison to native DNA.84,88,92 The impressive results obtained during the last few years strongly indicate that a complete error-free labeling of a DNA strand is within reach using new mutant polymerases. However, the sequence of a single DNA molecule can also be retrieved in several sequencing steps if the DNA is only partially labeled, e.g., if two kinds of fluorescently labeled nucleotides are substituted completely in varying combinations. A processive exonuclease is an exocnuclease that remains attached to and successively cleaves nucleotides from the same DNA strand. By using a processive exocnuclease that has the same cleavage rate on labeled and native nucleotides, it might be possible to obtain the complete sequence in only two sequencing runs if the dark gaps between detection of subsequent fluorescent signals can be interpreted as time allotted to the cleavage of unlabeled bases. If the cleavage rate of native and fluorescently labeled nucleotides differs, at least six sequencing reactions including all possible nucleotide combinations would need to be performed. To test and optimize the many steps (incorporation, optical detection, etc.) required for single-molecule DNA sequencing, it is useful to have model DNA with a known and planned sequence. Figure 6.10 shows such a model 218-mer DNA sequence developed by Rigler’s group.84 It contains 6 adenosine and 6 guanosine residues at well-defined positions with 15 filling nucleotides (thymidine and cytosine) between in a thermodynamically optimized and highly degenerate sequence. This is necessary to prevent, for example, possible inter- or intramolecular priming, because PCR-driven amplification of this model DNA is desired to produce large amounts of this sequence.
FIGURE 6.10 Sequence of the synthetic model 218-mer DNA developed by Rigler and co-workers.84 The adenosine (black) and guanosine (gray) residues indicate the incorporation positions for complementary labeled nucleotides dCTP and dUTP.
126
Analytical Techniques in DNA Sequencing
Thus, by using fluorescently labeled dUTP or dCTP derivatives alone or in combination, a total of up to 12 fluorescent labels (6 dUTP and 6 dCTP derivatives) can be incorporated enzymatically into one DNA strand in a defined sequence. For example, in sequencing a single DNA strand, the following sequence should be retrieved: UCCUUCCUUCCU. Due to the large distance between the label positions, the polymerase-mediated reaction occurs with various fluorescently labeled nucleotides without difficulties. The availability of such model DNA will allow for a well-defined calibration and optimization of all other steps involved in the development of a new singlemolecule DNA sequencing strategy, including (1) selection of single DNA strands, (2) determination of cleavage rates of different exonucleases on single- and doublestranded DNA, (3) determination of the influence of the dye structure (charge, hydrophobicity and linker arms) on the incorporation fidelity and cleavage rate, (4) determination of the frequency of misordering due to differences in the rate of transport of cleaved labeled dNTPs through the detection area, and (5) determination of the error rate of identification of the nucleotides by the spectroscopic properties of the fluorescent labels. An advantage of this system for optimization is that, even if more than a single DNA molecule is selected, a 1:1 ratio of the two fluorescently labeled dUMPs and dCMPs must be found. In addition, the number of detected and identified events should always be 12 (6 labeled dUMP and 6 labeled dCMP molecules) or a multiple thereof if more than a single DNA-strand was selected. To test and compare the cleavage rates of exonuclease enzymes on double- or single-stranded labeled DNA under various conditions, simple fluorescence intensity measurements in a conventional fluorescence spectrometer can be used. Due to intermolecular energy transfer between closely spaced chromophores via the Förster92 or Dexter93 mechanisms, highly labeled DNA exhibits relatively low fluorescence intensity. Hence, the efficiency of exonucleolytic cleavage can easily be monitored by the increase in fluorescence intensity with time using, for example, simple doubly labeled oligonucleotides (Figure 6.11). As pointed out previously, highly labeled DNA strands are expected to have dramatically different physical and chemical properties in comparison to native DNA.84,88,94 This might seriously deteriorate the successive cleavage of fluorescently labeled nucleotides by a DNA exonuclease. Although relatively little is known about the cleavage rate of exonuclease enzymes on highly labeled DNA, several reports have investigated this topic. For example, the turnover rate of exonuclease III on rhodamine-labeled double-stranded DNA was measured with three to seven nucleotides per DNA fragment per second at 36°C using enzyme excess.87 The cutting rate of T7-DNA polymerase on double-stranded rhodamine and Cy5-labeled DNA of 1 to 2 Hz at 16°C have been reported.95 However, the reported values do not represent the final cleavage rate of the exonuclease attached at the DNA strand. Besides the rate of cleavage itself, the overall measured cleavage rate is controlled by the rate that the exonuclease attaches to and detaches from the DNA strand, as well as the processivity. The attachment of the exonuclease involves the recognition of the DNA strand, and this is expected to be altered when the DNA is fluorescently labeled. Once attached to the DNA strand, all measurements performed thus far have indicated that highly processive exonucleases have substantially higher cleavage
Sequencing the Single DNA Molecule
127
FIGURE 6.11 Test of exonuclease cleavage rates on doubly labeled single-stranded 28-mer oligonucleotide 5′-T*GTAAAAT*GACGAGTTTACTAGTGAACT-3′ (T*: tetramethylrhodamine labeled thymidine). Fluorescence intensity of the oligonucleotide monitored at the emission maximum of tetramethylrhodamine upon addition of 30 units exonuclease I (black) and T7 DNA polymerase (gray) to 600 µl of a 10–6 M solution of single-stranded oligonucleotide. Conditions: 25°C, 20 mM Tris-borate, pH 8.4, 1 mM MgCl2.
rates (the measured average rates include the attachment). Furthermore, in singlemolecule sequencing experiments based on the exonucleolytic cleavage of single nucleotides from an immobile DNA strand, the exonuclease may be accelerated by the flow gradient applied for the purpose of moving the cleaved nucleotides to the detection area. By using the sheath flow technique, exonuclease molecules are accelerated by the relatively high sheath flow velocities of up to 1 cm/s.96,97 Application of electrical fields induces comparable accelerations of the exonuclease molecules.92,98,99 Independent of the method used, exonuclease recognition of the highly labeled DNA as substrate might be problematic. Furthermore, once attached, it might be detached from the DNA strand due to forces associated with the required flow. To avoid hairpin structures that might disturb the recognition and attachment of an exonuclease to the DNA, digestion of double-stranded DNA is generally preferred over single-stranded digestion. On the other hand, fluorescently labeled dNTPS exhibit a higher tendency to bind nonspecifically to double-stranded DNA as well as to proteins, e.g., streptavidin. Therefore, without careful purification steps, erroneous sequences might be obtained when adsorbed and released fluorescent dNTPs are detected along with enzymatically cleaved fluorescent dNMPs. To simplify purification, it would be much easier if the enzymatic degradation could be performed using single-stranded DNA. An exonuclease that shows high single-strand activity is exonuclease I (Exo I).94 Exo I digests single-stranded DNA in a 3′ → 5′ direction and is active under a wide variety of buffer conditions. In addition, Exo I is a highly processive exonuclease on single-stranded native DNA and has a high cleavage rate of 275 bases per second.100 Sauer and coworkers94 used Exo I to degrade
128
Analytical Techniques in DNA Sequencing
single-stranded labeled DNA in a micropipette and found cleavage rates of 3 to 24 Hz at room temperature using an aqueous buffer containing 30% glycerol and 0.1% (v/v) Tween 20.
SINGLE-MOLECULE DNA SEQUENCING IN HYDRODYNAMICALLY FOCUSED SAMPLE STREAMS An important prerequisite for single-molecule sequencing is the efficient detection of each fluorescently labeled nucleotide molecule with high S/B ratio. The importance of using small probe volumes to distinguish fluorescence from a single molecule from background emission from the solvent was already discussed. Hydrodynamic focusing of the sample stream in a sheath flow cuvette,29 an excitation laser beam focused to ∼10 µm, and a spatial filter in the detection path can be used to attain a detection volume of approximately 1 pl. Hydrodynamic focusing occurs when a sample stream is introduced into a rapidly flowing sheath stream from a small orifice. During focusing, the sample stream accelerates to catch up with the sheath stream keeping the volume flow rate of the sample constant. The focused sample stream is typically in the center of the flow cell where the flow profile is relatively constant. A diagram of an apparatus for single-molecule DNA sequencing used by Keller and coworkers96 is shown in Figure 6.12. The sheath flow cell is mounted on a three-axis translation stage to allow precise alignment of the sample stream to the focused excitation laser. Fluorescence is collected at 90° to the flow and excitation laser axes using a 40×, 0.85 numerical aperture (NA) microscope objective. Photomultiplier tubes (PMTs) or avalanche photodiodes (APDs) are used as detectors. The use of photon counting APDs for single-molecule detection is discussed in detail by Li and Davis.101 The main advantage of APDs is their high quantum efficiency in the visible region of up to 70%. Typical overall detection efficiencies with APDs can be as high as 5% when combined with high numerical optics and appropriate filters. The 1 pl volume contains approximately 3 × 1013 water molecules. Despite the small Raman scattering cross-section of a single water molecule of ∼10 –28 cm2 at 488 nm,19 the large number of molecules in this volume contribute to a total Raman scattering area that is larger than the absorption cross-section of a typical dye (∼10–16 cm2). For background rejection, it is helpful to use a pulsed laser system and time-gated detection. Fluorescence decay times of highly fluorescent molecules are typically in the range of a few nanoseconds while elastic and inelastic scattering occurs only during the laser pulse. A time-to-amplitude converter (TAC) can be used to process only photons arriving with a delay longer than, for example, 1 ns. This time-gating can result in a reduction of the detected Raman and Rayleigh scattered light of more than two orders of magnitude (Figure 6.13).19 Even with small probe volumes, there is often considerable background emission associated with fluorescent impurities in the solvent. This is an important limitation, especially in single-molecule sequencing experiments, where biological buffers and enzymes have to be used. For a 1 pl volume, fluorescent impurities present at a concentration of ∼10–12 M will give an average of one impurity molecule in the detection volume at any time. If the impurity is strongly fluorescent in the same spectral
Sequencing the Single DNA Molecule
129
TL MO5
CCDVC
SMF
BF
TS MO2
MO4 APD
SFC MO1
DBS
S
BPF
MO3
L EL
(a)
(b)
FIGURE 6.12 (a) Diagram of the experimental setup used to detect single molecules eluting from a microsphere. Legend: APD, single-photon counting avalanche photodiode; BF, blocking filters; BPF, bandpass filter; CCDVC, charge-coupled device video camera; DBS, dichroic beam splitter; EL, excitation laser; L, focusing lens; MO1, optical trapping/fluorescence collection objective; MO2, trapping laser fiber output coupling objective; MO3, fluorescence imaging objective; MO4, imaging objective; MO5, trapping laser fiber input coupling objective; S, slit; SFC, sheath flow cuvette; SMF, single mode fiber; TL, trapping laser; TS, threeaxis translation stage. (b) The sheath flow channel viewed along the excitation laser axis. The width of the square-bore flow channel is indicated by the white 250 µm scale bar near the bottom of the picture. Sheath fluid flows from top to bottom. An optically trapped 1 µm microsphere, illuminated with a HeNe laser (633 nm), is visible less than 20 µm upstream of the focused (16 µm e–2 diameter) excitation laser beam. The end of the sample delivery capillary (90 µm o.d., 20 µm i.d.) used for delivery of microspheres to the optical trap is visible ∼200 µm upstream of the excitation laser. (From NP Machara et al., Bioimaging 6:33–42, 1998. With permission.)
region as the analyte of interest, fluorescence bursts from impurities can be mistaken for analyte detection. If the impurity is only weakly fluorescent, it will contribute to a quasi-continuous background. It has been shown that the background from impurities can be reduced by one order of magnitude or more by photobleaching the sheath fluid before introducing the analyte.102 As a result of these improvements, single fluorescent molecules can be easily detected in hydrodynamically focused sample streams with high S/B ratios.19,24,45,46,55,59,96 Detection of each fluorescent molecule present in the sample stream is an important prerequisite for single-molecule DNA sequencing. Efficient sample delivery to 1 pl volumes requires sample stream diameters less than 10 µm. To reduce broadening of the sample stream due to radial diffusion, flow velocities of ∼1 cm/s are needed. This means that the transition times of single molecules through the laser focus are in the range of 1 ms, comparable to typical transition times of freely diffusion molecules through confocal probe volumes of ∼1 fl.37–39 For rapidly diffusing analyte molecules, such as fluorescently labeled nucleotides, one positions a tapered sample injection capillary with a inner diameter of ∼1 µm as close to the detection volume
130
Analytical Techniques in DNA Sequencing
Count rate (kHz)
400
300
raw
200
100 time-gated 0 0
100
200 300 Time (ms)
400
500
FIGURE 6.13 Detection of single R6G molecules using pulsed excitation and TCSPC to discriminate against Raman scattering background. The top curve shows 500 ms of raw data binned into 1-ms intervals. The bottom curve (time-gated) is the same data processed to remove photons detected within ∼1 ns of the excitation laser pulse. (From WP Ambrose et al., Chem Rev 99:2929–2956, 1999. With permission.)
as possible.103,104 Because of increase in background associated with scattered light and fluorescence from the capillary tip, it is normally preferable if the capillary output and detection volume do not overlap. In a typical experiment, the analyte is dissolved in a salt buffer and is delivered electrokinetically into the sheath flow from a pulled microcapillary located approximately 50 µm upstream from the focused excitation laser beam.19 Burst size distributions detected from single rhodamine molecules under these conditions showed a peak at ∼40 photon counts. When the sample stream diameter is larger than the detection volume, the burst size distribution decreases monotonically from zero photon counts. For a detection threshold set to 20 photon counts, simulation predicts that >90% of the molecules leaving the capillary are detected.105 The good agreement found between experiment and simulation corroborates the assertion that single molecules are indeed detected.19 According to the simulation, approximately 10% of the molecules photobleach while crossing the probe volume; about half of these are detected before they photobleach. In addition to scattered light and fluorescence from the capillary tip, there are other problems associated with capillary sample introduction. Perturbations of the sheath fluid flow by the capillary can broaden the sample stream. Also, adsorbed fluorescent impurities released from capillary surfaces contribute to the background. Therefore, new sample delivery methods have been investigated that avoid scattering from the capillary tip and simultaneously ensure a short diffusion time of released analyte molecules to the detection volume.96 In Reference 96, efficient sample delivery was achieved from a 1-µm-diameter microsphere optically trapped ∼20 µm upstream of the detection volume. Because of the short transport time to the detection volume, diffusional broadening of the sample stream is significantly reduced, thereby enabling single-molecule detection efficiencies greater than 90%. Microspheres were introduced
Sequencing the Single DNA Molecule
131
into the sheath flow by a 20-µm i.d. capillary positioned approximately 200 µm upstream of the detection volume (Figure 6.12). A water immersion microscope objective was used for both optical trapping and fluorescence collection.106,107 A laser power of approximately 500 mW provided by a ND+:YAG laser (1.06 µm) was used for trapping. Fluorescence of single rhodamine 6G (R6G) and tetramethylrhodamine isothiocyanate (TRITC) molecules was excited using a mode-locked Ar+ laser operated at 514.5 nm at a repetition rate of 82 MHz. This laser system provided pulses with a length of 0, the positions of the two homologous segments are not interchangeable, so that there are about m2 ways of selecting the event (rather than m2/2), and its probability can be expressed as m2πJ, for some coefficient πJ. A detailed analysis of the terms πJ for J > 0 is rather cumbersome, so that we shall resort to appropriate approximations. The following informal observation will intuitively support the chosen approximations. We begin by noting that the spectrum must contain a set of fooling probes necessary to compensate for the disagreements between the two competing segments (aligned on the two paths). Precisely, no probe is required at a position 0 ≤ j < J if and only if no disagreement (between the two alternative paths) occurs at positions {j, j − 1,…, j − s + 1, j − 2s + 1,…, j − v + 1} ∩ {0, 1,…, j}. Thus, a single disagreement may require the presence of several compensating fooling probes, and since a disagreement is three times as likely as an agreement, we may expect that there will be a fooling probe (with its rightmost symbol) at nearly every position in [0, J − 1]. If each position required a fooling probe, then we would have πJ =
3α J 4 v−1− J
However, not all positions demand a fooling probe (although, most of them do). Here we make the convenient simplification that “things are as if θJ positions do require a fooling probe,” where parameter θ ≤ 1 is a function of m and J, so that πJ =
3α θJ 4 v−1− J
To obtain additional insight into parameter θ, a little reflection justifies the fact that, given a J-bit string describing the positions of agreement/disagreement, the positions of the required fooling probes are obtained by convolving the J-bit string with the reverse of the probing pattern: the nonzero terms of the convolution define the fooling probe positions. Almost all of the obtained convolutions have weight J, which would suggest θ ≈ 1. However, the few convolutions with weight <J have much higher probability (since they invoke fewer fooling probes); this fact, for smaller values of α, decreases the value of θ. Thus, we expect θ to increase with α and to decrease with J. Detailed computer analysis suggests that, as a coarse approximation, we may take θ = 0.9, independent of α and J for the most interesting probing patterns (for example, reverse (4,4) probes).
Sequence Reconstruction from Nucleic Acid Microarray Data
187
We conclude that v
∑π
=
J
J =1
3a 1 − (4a q )v ⋅ 4 v − 2 1 − 4a q
(8.5)
For J > v, terms πJ are essentially negligible. However, within the stated approximation, θ(v − 1) fooling probes are required for the self-sustaining segment; in addition, by the same argument, we may say that a fooling probe is required for each of positions 0, 1,…, J − v, so that π J = 3α J −v +1α θ( v−1) =
3 J −v +1 α (4α θ )v−1 4 v−1
and
∑π J >v
J
=
3α 2 ( 4α θ )v−1 ⋅ 4 v−2 4(1 − α )
(8.6)
Putting Equations 8.4 through 8.6 together, we obtain the following estimate of the probability of Mode 2 failure: P2 =
3m 2 ⎛ 1 1 − ( 4α θ ) v ( 4α θ )v−1 ⎞ +α + α2 ⎟ θ v−2 ⎜ 4 ⎝ 32 1 − 4α 4(1 − α ) ⎠
(8.7)
Results of the described analyses have been found to be in excellent agreement with extensive simulations using random sequences.
PERFORMANCE OPTIMIZATION We repeat below, for convenience, the estimates of the probabilities of Mode 1 and Mode 2 failures as obtained in the preceding section (with the choice θ = 0.9): m P1 = 3m ⎛ k ⎞ ⎝4 ⎠ P2 =
k
3m 2 ⎛ 1 1 − ( 4α θ ) v ( 4α θ )v−1 ⎞ +α + α2 ⎟ θ v−2 ⎜ 4 ⎝ 32 1 − 4α 4(1 − α ) ⎠
(8.8)
(8.9)
The functions 1 − P1 and 1 − P2 are, respectively, plotted in Figure 8.3 and Figure 8.4 in the range [0.9, 1] for k = 0, with independent variables r and m. We note that, whereas P1 depends exclusively on the parameter k, P2 strongly depends on v, and, consequently, on s and r. Indeed, Failure Mode 2 is the basis for performance
188
Analytical Techniques in DNA Sequencing
0 0.98 0.96 0.94 0.92 0
0 1
00
2
40
3
00
80 m
4 5
0 00
12
16
00
0
r
6 7
FIGURE 8.3 Diagram of the function 1 − P1(m, r) for a (4,4) probing scheme.
optimization; this is not surprising, as the choices s = 1 and s = k both yield as a special case the standard method, whose performance is known to be very poor. The analogous plot of 1 − P1 − P2 (the probability of successful reconstruction) in the range [0.9, 1] is displayed in Figure 8.5; this diagram illustrates that small or large values of r yield designs not substantially different from the standard one, and that the best performance is achieved for r ≈ s: indeed, designs (4, 4) and (5, 3) have identical best performance. We now attempt a quantitative assessment of this performance. Simple analysis of Equations 8.8 and 8.9 shows that Failure Mode 1 is dominant in the range of interest (where P1 + P2 is significantly > 0). Thus, for a small value ε, we wish to determine the solution m* of the equation P1 ( m) = ε Using approximation (8.3), we have 1
ε 2 k +1 m = ⎛ 4k ⎞ ⎝3 ⎠ =4
k −1 −
1 4ε log 3 k +1
which shows that we have a gap of a factor a little larger than 2 between achievable performance and bound (Equation 8.1).* Although from the viewpoint of asymptotic
Sequence Reconstruction from Nucleic Acid Microarray Data
189
0 0.98 0.96 0.94 0.92 0
0 1
00
2
40
3
00
80 m
4 5
00 2,0
1
16
,00
0
r
6 7
FIGURE 8.4 Diagram of the function 1 − P2(m, r) for a (4,4) reverse probing scheme.
analysis the issue of optimality is settled, further algorithmic improvements are practically very important. Exploring possible improvements, we note that the outlined algorithm, upon detection of failure, makes no use of information provided by the currently constructed prefix of the putative sequence. Indeed, upon failure the algorithm cannot discriminate between two competing sets of probes, either of which may be fooling. Intuition suggests, however, that only probes pertaining to the spurious alternative are guaranteed to be scattered along the sequence, whereas those pertaining to the correct extension are mostly concentrated around the current position. Therefore, further discrimination is provided by the relative counts in the prefix of the probes for the two alternatives. We call “polling”12 a decision based on this count, and we could show by probabilistic analysis (confirmed by empirical evidence) that a further gain of about 20% in performance can be obtained over the algorithm not using the polling provision, thereby achieving performance m ≈ 0.2⋅4k.
CONCLUDING REMARKS We have analyzed in some detail the combinatorics of sequence reconstruction in SBH. There are, however, several additional aspects of the problem that we should address in order to place the topic in the appropriate perspective. These aspects concern the * This can be readily verified from the approximate equation 3mαk = ε, with the initial estimate m = 0.25 ⋅ 4k and ε = 0.1.
190
Analytical Techniques in DNA Sequencing
0 0.98 0.96 0.94 0.92 0
0 1
00
2
40
3
00
80 m
4
1
20
5
00 0 16
00
r
6 7
FIGURE 8.5 Probability of correct sequence reconstruction for a (4,4) reverse scheme as a function of m and r.
biochemistry of DNA hybridization, the gauge of optimality (the information-theory bound), and the nature of actual genomic sequences.
THE BIOCHEMISTRY
OF
DNA HYBRIDIZATION
All combinatorial analyses of SBH make some drastic simplifications of hybridization, which is usually portrayed as a noiseless process. In this modeling, string match/ mismatch correspond, respectively, to perfect hybridization or no hybridization at all. The reality is much more complicated. First of all, Watson/Crick-complementary binding (match) is the result of the individual binding of the base pairs involved; despite the obviously additive character of binding energy, there is some interaction between adjacent base pairs. Second, a mismatch (a pairing of two noncomplementary bases) produces only a limited destabilization, which does not qualitatively alter the nature of the process. DNA match/mismatches have been carefully modeled and experimentally observed,13 and parameters are available to evaluate rather accurately the binding energy of a specific DNA duplex (a pair of equal-length strings). A less drastic simplification of hybridization assumes independence between adjacent positions and distinct binding energies for strong (C-G) and weak (A-T) base pairs (normally, in a simplistic 2/1 ratio). But even these simplifications lead to a substantial spread in the distribution of the binding energies of complementary duplexes of a given length. Because binding energy is a monotonic function of the
Sequence Reconstruction from Nucleic Acid Microarray Data
191
temperature of annealing (related to the melting temperature), the resulting spread of melting temperatures for the different microarray probes considerably complicates the biochemical experiment. Presumably, the melting temperatures of each microarray feature should be individually measured. This brief discussion points to experimental difficulties that either should be overcome in the laboratory or may themselves modify the combinatorial model of SBH. The issue of noisy SBH has been addressed in the literature,5,7,8,14,15 with a convenient model that assumes that false positives and false negatives are Poisson processes. Clearly, false negatives are much more detrimental than false positives, as they fatally interrupt the reconstruction process, while false positives basically add to the fooling probe pool. The mentioned biochemical difficulties have so far prevented SBH from becoming a truly competitive technology for de novo DNA sequencing.
A GAUGE
OF
OPTIMALITY
The standard practice is to compare SBH methods on the basis of their conventional performance, expressed as the length of random sequences that are reconstructed with a prescribed confidence level. However, it is desirable to evaluate a method against some absolute gauge of optimality. Such a gauge is, currently, the information-theory bound (Equation 8.1) introduced earlier. In all fairness, this bound is unsatisfactory for a number of reasons. First, it simply states that for m ≥ 4k − 1/2 there are pairs of sequences with identical spectra, a fact that may be of no practical consequence if such sequences were a rarity. Second, it takes into consideration “illegal” spectra, that either contain more distinct probes than there are symbols in the target sequence, or such that their probes do not correspond to all subsequences of a target sequence. More significant is perhaps a gauge related to the sequential nature of the reconstruction of the putative sequence, as carried out by all algorithms dealing with this problem. Such a process may be viewed as the construction of a rooted tree, each of whose paths (from the root) is fully supported by the spectrum. Basically, one such path, reproducing the target sequence, is deterministically extended, and spawns spurious paths in a random fashion. Each spurious path may in turn spawn additional spurious paths, and the phenomenon may appear as a branching process, except for the fact that successive extensions are not truly independent. Non-overlapping probes are independent in our memoryless model. Suppose that m has a value sufficiently large for the tree extension to become significant, say, m ≥ 4k−1. In such case α > 0.2212…. It is easily shown that the maximum overlap of two distinct (s, r)-gapped probes is s − 1, so that the overlap of two probes at the same site involves the constraint of at least k − s + 1 = r + 1 additional symbols. We conclude that for r ≥ 3, α >> 1/4r+1, so that we may reasonably ignore probe overlap so that probes may be considered independent. Let us denote conventionally as 0 the position where a branching occurs, i.e., where the correct path (subtree) deviates from the spurious paths (subtrees). Let random variable nj denote the number of leaves of one of the spurious subtrees at position j, and let pj be the probability that a tree node has j descendants. Obviously, n0 = 1 and the generating function P(ζ) = Σ4i=0 pi ζi has the expression (1−α + αζ)4
192
Analytical Techniques in DNA Sequencing
in our model (i.i.d. symbols). Denoting Pj (ζ) the generating function of the distribution of nj, it is well known that Pj+1(ζ) = P(Pj (ζ)) (see Feller,16 p. 272). Moreover, unbounded growth of tree depth j has nonzero probability for values of {p0, p1,…, p4} for which the equation ζ = P(ζ) has a real solution 1, i.e., P′(1) = 4α(1 − α + αζ)3 |ζ=1 = 4α > 1 which is equivalent to α > 1/4, or m > 4 k In
4 ≈ 0.288 ⋅ 4 k 3
Thus, m ≈ 0.288 ⋅ 4k is the critical value for potential explosion of the number of paths. With respect to this bound, using the results presented earlier, the performance gap is narrowed to the interval [0.2 − 0.288] ⋅ 4k.
PROCESSING NATURAL DNA As mentioned earlier, the common standard for performance evaluation is the ensemble of sequences generated by maximum-entropy memoryless quaternary source. This standard enables comparative evaluations of different methods, but does not necessarily model the reality of natural sequences, which indeed deviate, sometimes substantially, from this random abstraction. Deviation from memoryless randomness follows some general, but sometimes elusive, pattern: short genomes (typically, prokaryotic) appear sufficiently random, whereas more complex genomes (typically, eukaryotic) show marked deviations, especially in the noncoding or intronic regions of the genome. Loss of randomness may consist of unequal symbol frequencies, presence of source memory, nonstationary source behavior, and the occurrence of “repeats,” sometimes in the form of long, nearly identical segments sufficiently far apart, sometimes in the form of long concatenations of short periods. The latter feature is frequent in higher organisms, and subtle algorithmic provisions are needed to detect and control such periodicities.
REFERENCES 1. Issue of Science devoted to “The Human Genome.” Science, 291(5507), 1145–1434, 2001. 2. Yu.P. Lysov, V.L. Florentiev, A.A. Khorlin, K.R. Khrapko, V.V. Shih, and A.D. Mirzabekov, Sequencing by hybridization via oligonucleotides. A novel method. Dokl Acad Sci USSR, 303, 1508–1511, 1988.
Sequence Reconstruction from Nucleic Acid Microarray Data
193
3. P.A. Pevzner, l-Tuple DNA sequencing: computer analysis. J Biomol Struct & Dyn, 7(1), 63–73, 1989. 4. R. Drmanac, I. Labat, I. Bruckner, and R. Crkvenjakov, Sequencing of megabase plus DNA by hybridization. Genomics, 4, 114–128, 1989. 5. W. Bains and G.C. Smith, A novel method for DNA sequence determination. J Theor Biol, 135, 303–307, 1988. 6. M.E. Dyer, A.M. Frieze, and S. Suen, The probability of unique solutions of sequencing by hybridization. J Comp Biol, 1, 105–110, 1994. 7. P.A. Pevzner, Yu.P. Lysov, K.R. Khrapko, A.V. Belyavsky, V.L. Florentiev, and A.D. Mirzabekov, Improved chips for sequencing by hybridization. J Biomol Struct Dyn, 9(2), 399–410, 1991. 8. P.A. Pevzner and R.J. Lipshutz, Towards DNA-sequencing by hybridization. Proceedings 19th Symp on Mathem Found of Comp Sci, LNCS-841, 1984, 243–258. 9. E.M. Southern, DNA chips: analysing sequence by hybridization to oligonucleotide on a large scale. Trends Genet, 12(3), 110–115, 1996. 10. D. Loakes and D.M. Brown, 5-Nitroindole as a universal base analogue. Nucleic Acids Res, 20, 4039–4043, 1994. 11. F.P. Preparata and E. Upfal, Sequencing-by-hybridization at the information-theory bound: an optimal algorithm. J Comp Biol, 7(3/4), 621–630, 2000. 12. S.A. Heath and F.P. Preparata, Enhanced sequence reconstruction with DNA microarray application. Proceedings of COCOON 2001, Guilin, China, 2001, 64–74. 13. J.J. SantaLucia, A unified view of polymer, dumbells, and oligonucleotide DNA nearest-neighbor thermodynamics. Proc Natl Acad Sci USA, 95, 1460–1465, 1998. 14. R.J. Lipshutz, Likelihood DNA sequencing by hybridization. J Biomol Struct Dyn, 11, 637–653, 1993. 15. K. Doi and H. Imai, Sequencing by hybridization in the presence of hybridization errors. Genome Informatics, 11, 53–62, 2000. 16. W. Feller, An Introduction to Probability Theory and Its Applications. New York: John Wiley & Sons, 1960.
9
Ancient DNA William Goodwin
CONTENTS Introduction ..........................................................................................................195 The Process of DNA Decay and DNA Preservation ............................................196 DNA Degradation ......................................................................................196 Jumping PCR and DNA Damage..............................................................197 Assessment of Molecular Preservation .................................................................199 Environmental............................................................................................199 Chemical ....................................................................................................200 Limitations of Ancient DNA Analysis ..................................................................201 Substrates for Ancient DNA Analysis...................................................................201 Technical Procedures in Ancient DNA Analysis .................................................202 DNA Extraction ........................................................................................202 PCR Amplification and Sequencing..........................................................203 Authentication............................................................................................204 Target Loci ................................................................................................205 Applications of Ancient DNA Analysis ...............................................................206 Human Evolution and the Place of the Neanderthals...............................206 Background ......................................................................................206 Samples ...........................................................................................207 DNA Extraction and Sequence Analysis ........................................207 The Age of Divergence ...................................................................209 Neanderthal Diversity ..................................................................... 210 Admixture.........................................................................................210 Phylogeny and Population Genetics Using Extinct Animal Populations .............................................................................. 211 The Origins and Spread of Agriculture.................................................... 211 Future Directions for Ancient DNA .....................................................................212 References ............................................................................................................213
INTRODUCTION The first publications reporting the analysis of ancient DNA were greeted with a great deal of interest from several academic disciplines and also the general public, excited by the potential of addressing previously unanswerable questions. From this initial interest and excitement, the discipline of ancient DNA analysis was born. 195
196
Analytical Techniques in DNA Sequencing
The technological catalyst was the development of the polymerase chain reaction (PCR) technology,1 which for the first time allowed extremely small amounts of degraded DNA to be analyzed. This opened up for the first time the possibility of studying DNA extracted from a plethora of samples, which could address questions of evolutionary, archaeological, and historical importance. The reality of what could be achieved by analyzing ancient DNA did not live up to the initial expectations. Many of the early reports that claimed that DNA could be extracted from plant and animal remains millions of years old, which generated headlines in both the popular and scientific press, could not be substantiated and have since been explained by contamination from modern sources. These early erroneous claims placed the whole discipline of ancient DNA analysis in a poor light. The contamination was a negative aspect of the PCR; this method, which opened the possibility of analyzing small amounts of degraded material, does not distinguish between modern contaminating DNA and the endogenous DNA that is of interest. Despite these setbacks, an increased understanding of the processes involved in DNA degradation led to improved technical processes for extracting and amplifying ancient DNA. In addition to the technical advances, the establishment of rigid criteria that have to be satisfied before ancient DNA can be accepted as being from the sample of interest and not the result of contamination provide a more structured framework in which to work. Because of these advances a large body of reliable work is now accumulating, which is being used to address a number of questions. This chapter discusses the analysis of ancient DNA; what constitutes ancient DNA is debatable and the chapter could equally be entitled “Degraded DNA.” The methodology and theory behind the analysis of DNA that is 50,000 years old is largely the same as that used for DNA only a few years old if the DNA is equally degraded, even if the questions asked in the study may be different. In the chapter the processes that are important in the preservation of DNA are discussed and an overview of the controls that have to be satisfied before the results of any study can be accepted are addressed. In the second part of the chapter some specific example covering areas from human evolution, taxonomy, archaeology are discussed.
THE PROCESS OF DNA DECAY AND DNA PRESERVATION DNA DEGRADATION When an organism dies, its DNA will start to degrade. Nucleases that are compartmentalized within the living cell are released upon cell breakdown and start to degrade the endogenous DNA. Colonizing bacteria and fungi will continue the enzymatic breakdown. This process is especially rapid in soft tissues that rapidly putrefy unless the process is arrested by low temperatures, desiccation, or chemical environments that inhibit the action of the nucleases. Even when the endogenous DNA is in a relatively stable environment the DNA will continue to break down over time due largely to the effects of hydrolysis and oxidation (Figure 9.1).2 Hydrolytic damage will result in the removal of bases; purines are particularly susceptible to this process and depurination is one of the main routes of ancient
Ancient DNA
197
Sites susceptible to: Hydrolytic attack Oxidative damage
FIGURE 9.1 The degradation of DNA. The major sites at which DNA degradation proceeds either through oxidative or hydrolytic reactions are indicated. (Permission to reproduce modified figure from Lindahl, 1993.)
DNA degradation. Oxidative damage leads to lesions in the sugar-phosphate backbone of the DNA molecule and chemical alterations of the bases; the oxidative damage is mediated through the effects of both direct and indirect ionizing radiation.2
JUMPING PCR
AND
DNA DAMAGE
DNA degradation and damage, in addition to limiting the length of any fragment of DNA that might reasonably be found in a fossil sample, also complicates the PCR amplification process. The DNA damage can lead to two processes that can produce erroneous and, at times, misleading results. These errors can occur through two processes: jumping PCR and the incorrect incorporation of residues caused by DNA damage. The phenomena of jumping PCR can knit partial PCR products together resulting in hybrid molecules.3 If extension occurs from a primer but is terminated prematurely due to DNA damage, the resulting truncated PCR product can then act as primer in the next round of PCR. The priming now starts farther downstream of the original
198
Analytical Techniques in DNA Sequencing
Two different nucleotide substitutions in two alleles are indicated by shaded circles
DNA degradation leads to short overlapping fragments
Extension in the PCR is incomplete
Primer
The incomplete extension product acts as a primer in a later round Primer
A hybrid molecule is produced
FIGURE 9.2 When two variants of an allele are present in a sample of degraded DNA, it is possible to form a hybrid molecule through the process of jumping PCR.
Ancient DNA
199
primer site and can lead to the formation of a hybrid molecule (Figure 9.2). This can lead to problems in interpreting data, particularly from loci that may well have two different alleles within any given individual. Damaged DNA is also more problematic for the Taq (Thermo aquaticus) DNA polymerase to copy; the purine bases, guanine (G) and adenine (A), are particularly prone to hydrolytic attack leaving the DNA template with gaps in the sequence of bases. If the damage is severe enough, PCR-mediated amplification may prove impossible; in one study oxidation-mediated chemical changes in the pyramiding bases were shown to be positively correlated with the inability to amplify endogenous DNA.4 Deamination, in particular of the cytosine residue, has been shown to be common in both the DNA of living organisms and fossils.5 The deamination of the cytosine base will lead to detection of transitions in the PCR products that are artifacts of the DNA damage rather than reflections of the endogenous sequence. After deamination of the cytosine base, Taq DNA polymerase will incorporate deoxyadenosine residues at a position where a deoxyguanosine would have been incorporated prior to the deamination, leading to an incorrect cytosine (C) to thymine (T) and G to A transitions.
ASSESSMENT OF MOLECULAR PRESERVATION Many samples that could be considered interesting to analyze will not contain any endogenous DNA. In such cases there is little merit in undertaking destructive analysis that is expensive and time-consuming and has no possibility of yielding results. Whenever multiple samples are available for analysis, it is advantageous to determine which of the samples provides the greatest probability of yielding ancient DNA. Through empirical observations and an improved understanding of the process of DNA degradation, the likelihood of a sample yielding DNA can be estimated. Although consideration of the environment in which the sample has been found, along with a chemical analysis, can virtually exclude the possibility of finding ancient DNA, it is important to realize that a positive assessment is no guarantee that endogenous DNA will be recovered from a given sample; rather it is an indication that the sample could potentially harbor ancient DNA. In addition to estimating whether obtaining ancient DNA is a possibility, positive indicators, environmental and chemical, also provide confidence in any results when ancient DNA is extracted and analyzed.
ENVIRONMENTAL The environment plays a large role in the rate of DNA degradation. Low temperature is generally considered to be the most important single factor in the preservation of ancient DNA. Temperature directly controls the rate of chemical reactions; generally a chemical reaction rate doubles with an increase of 10°C. It is therefore not surprising to find that most of the successful analyses involving ancient DNA have been with samples that are from cooler climates. Beyond the general observations, a more detailed survey of a number of fossils recovered from Pleistocene (an epoch dating 10,000 to 1.64 million years ago) sites demonstrated a positive correlation between the thermal age of the fossils and the recovery of endogenous DNA. As was expected,
200
Analytical Techniques in DNA Sequencing
lower that the average temperatures were positively correlated with a higher probability of retrieving ancient DNA.6 (Thermal age is the number of years required at a constant temperature of 10°C to produce the equivalent degradation that would have occurred based on its thermal history.) The effect of temperature on the chemical preservation of DNA has been demonstrated directly in studies where higher levels of chemical damage in ancient DNA have been correlated directly with higher environmental temperatures.4 Although temperature is the most important single factor, other environmental factors have to be taken into consideration when estimating if DNA could be present in a sample, including air and soil humidity, soil pH, average temperatures in different earth layers, and microbial-mediated decay.6,7 The interplay of these and other factors makes predicting the preservation of material from a site based on environmental information complex, and the information can act only as a guide rather than being definitive. This point is illustrated by the variation in gross and molecular examination of human bodies recovered from the same archaeological site and therefore sharing the same thermal history and also most other factors in involved in the degradation of DNA.8 The variations in microenvironments make precise predictions of ancient DNA preservation very difficult.
CHEMICAL The direct chemical assessment of a sample can provide information on the degree of diagenetic changes that has occurred in a sample. This has the advantage over the assessment based only on the environment history of measuring the actual sample that will be used in the ancient DNA analysis and therefore removing variables such as different microenvironments. It does have the disadvantage, however, that it is also a destructive technique; careful consideration therefore must be given before valuable samples are analyzed. Proteins that are present in all biological matter are more stable and easier to analyze than the DNA and therefore provide a good proxy for assessing DNA degradation. Assessment of changes in the proteins allows a measure of diagenetic change, which in turn provides an estimation of the amount of ancient DNA degradation and modification that is likely to have occurred. The most widely used method has been the measurement of different forms of amino acid. With the exception of glycine, amino acids can exist in the form of two optical isomers, D and L. In living organisms the L-enantiomer is exclusively used in protein biosynthesis. However, when the amino acids are no longer part of a living organism (i.e., upon death), they undergo racemization to the D-enantiomer; eventually the two forms will reach equilibrium at which point they will be present at equal levels. Measurement of the racemization of aspartic acid found that when the D/L ratios were below 0.08 DNA could be extracted and that generally with lower D/L ratios longer PCR products could be generated. Samples with D/L ratios above 0.08 yielded no endogenous ancient DNA.9 Collagen content and composition in bone7,10 and flash pyrolysis with gas chromatography and mass spectrometry11 are other methods that have shown the potential to be good indicators of the preservation of endogenous DNA.
Ancient DNA
201
LIMITATIONS OF ANCIENT DNA ANALYSIS The unfounded optimism of the early days of ancient DNA analysis, which led to hopes of extracting DNA from a plethora of samples stretching back in time millions of years, has all but died. Early reports, the most spectacular of which included the recovery of DNA from Miocene plant material 17 million to 20 million years old,12 from insects that had been embedded in amber up to 120 million to 135 million years,13,14 and finally from dinosaurs dating to the Cretaceous period (a geological period 65 million to 146 million years ago),15,16 have all proved impossible to repeat. With an increased understanding of the process of DNA degradation and therefore the limitations of its application, it is now generally accepted that it is very unlikely that endogenous DNA will be recovered from any samples older than 50,000 to 100,000 years, even with extremely favorable environmental conditions. The only way that information can be gained on the DNA sequences older than around 100,000 years is through inference, using extant sequences as a guide.
SUBSTRATES FOR ANCIENT DNA ANALYSIS The most abundant source of material for ancient DNA analysis is bone. This is normally all that is left of a vertebrate after decomposition. In exceptional circumstances soft tissue is also available. This occurs when a body or part of a body has become mummified, either naturally through desiccation or chemical environment or else through human intervention such as the numerous mummies from Egyptian antiquity and an enormous amount of animal skins preserved in museum displays. Organisms, in particularly mammoths and other Pleistocene megafauna, that are periodically recovered from melting ice or from areas of permafrost where they have been entombed since death periodically provide another source of soft tissue. However, even when preserved soft tissue is available for analysis, bone is normally the material of choice. The bone material acts as a valuable harbor for endogenous DNA; in addition to its resistance to putrefaction, the hydroxyapatite mineral in the bone stabilizes the DNA molecules and therefore aids in their preservation (see Lindahl2). Bone also has other advantages over soft tissue. Because relatively large pieces of bone are recovered, it is possible to remove the outer layers of the bone and therefore remove any contaminating DNA. In many cases it has also been easier to isolate DNA from bone material without co-extracting PCR inhibitors that prevent any analysis. Teeth are also highly desirable as a source of ancient DNA. In addition to the advantages that teeth share with bone samples, the tooth enamel acts as a natural barrier to bacterial and fungal invasion, which further helps to preserve the endogenous DNA. They are also relatively easy to clean; vigorous chemical treatment can be used to clean the surfaces without damaging the internal DNA. In the early days of ancient DNA analysis amber was thought to be a good potential source of ancient DNA. Amber provides a good potential harbor for DNA because of the desiccation of the material and the barrier to atmospheric oxygen, and the prospects of well-preserved material led to several attempts to analyze insects that had been entombed in amber, but these all failed to yield ancient DNA. Amber, while protecting specimens to some degree, has since been shown to be insufficient
202
Analytical Techniques in DNA Sequencing
to stop diagenetic changes to the encased material, particularly over the long time periods that the material has often been in the amber.17 Coprolites (fossilized feces) have also shown themselves to be an unlikely, if limited, source of ancient DNA and a valuable resource for studying the diets of other climatic periods.18,19 When dealing with botanical samples, seeds have proved to be the most promising source. Desiccation is a normal and controlled part of seed formation and therefore seeds have an immediate advantage over other sources of botanical material in that they are designed to harbor DNA for a period of months and even years. Ancient DNA has been reported to have been extracted from material from Greece dating back as far as the early Bronze age (see Brown20).
TECHNICAL PROCEDURES IN ANCIENT DNA ANALYSIS DNA EXTRACTION Once a sample has been assessed in terms of its age, molecular preservation, and environmental history, the endogenous DNA must be extracted. At all times during the extraction process rigorous precautions must be followed to minimize the possibility of contamination with exogenous DNA and controls are included to maximize the possibility of detecting any potential sources of contamination. Ideally, a laboratory that is dedicated to ancient DNA analysis should be used. The exact processes depend on the nature of the material that is being analyzed. Bone material has the advantage over many other potential samples in that the external surface, which may well contain contaminating DNA, can be removed. After the outer layer has been removed, the bone can be further treated with agents that will destroy DNA on the surface; common treatments include washing in strong detergents and sodium hydroxide solutions and treatment with intense ultraviolet (UV) light. When these steps are not possible, then care must be taken to use samples that have a low chance of being contaminated. The extraction method varies depending on the sample but is usually a variant of techniques commonly used when analyzing bone samples. The sample is ground to a fine powder and then dissolved in a 0.5 M EDTA solution; the addition of proteinase K aids the process. Nonbone samples are often powered by grinding in the presence of liquid nitrogen and then incubated in solutions containing detergents and also proteinase K to break down the cellular material and place the ancient DNA into solution. Separating the endogenous DNA from all types of ancient samples can be problematic due of the DNA becoming chemically linked to protein components. The addition of the chemical PTB (N-phenacylthiazolium bromide), which is a reagent that cleaves glucose-derived protein cross-links, to the DNA extraction has proved helpful in recovering ancient DNA from both coprolite and bone material.18,21 Once the ancient DNA is in solution, it is then most commonly further extracted using phenol and chloroform before the DNA in the aqueous phase is concentrated using filter centrifugation. Further cleanup procedures may have to be undertaken on the extract to remove inhibitors of the PCR reaction.
Ancient DNA
203
A vital part of any extraction involving ancient DNA samples is that negative controls have to be set up for all stages of the extraction procedure to monitor for external contamination. Even in the most stringently controlled environmental contamination can still occur. The extracts from fossil samples cannot be easily quantified as the levels of DNA are normally very low; large amounts of DNA will sometimes be present but the source of this DNA is virtually always bacterial or fungal rather than from the sample. Competitive PCR is one method than can be used to estimate the number of molecules that are present in an extract,22 and the development of real-time quantitative PCR is now a viable alternative.23
PCR AMPLIFICATION
AND
SEQUENCING
In fossil samples only a small number of chemically modified molecules can normally be recovered.4 While early studies attempted to analyze ancient DNA directly without an amplification phase,24,25 the low number of starting molecules made such analysis extremely difficult and the technique was of limited scope. PCR circumvented the problem of a low number of starting molecules; the technique is extremely powerful: in theory, one single molecule can be amplified several billion times and generate enough product to analyze directly. Over the last 13 years the PCR-mediated amplification of selected target loci has proved to be an extremely powerful technique in ancient DNA analysis, as in virtually all areas of molecular biology. However, the power of the technique can also be a problem as any contaminating DNA that enters the DNA extract or PCR reaction will also be amplified and it will not be possible to distinguish endogenous DNA from contaminating molecules. Because of chemical damage to the endogenous DNA, any contaminating DNA that is present in the PCR reaction may well be amplified preferentially. In the resulting DNA extract, if any endogenous DNA is present, in most circumstances only a few molecules will be present. Multiple PCR amplifications from ancient DNA extracts are an important step to undertake when the number of target molecules in an ancient DNA extract is very low. When the number of target molecules is limited, any errors that are introduced into the PCR product at an early point in the amplification process will appear in most or all of the cloned PCR products and will therefore appear to be the actual sequence of the endogenous DNA. By undertaking multiple amplifications, ideally from both the same and duplicate extractions, the risk of the same errors being incorporated into the PCR products is low. A possible source of errors during PCR amplification of ancient DNA is through the deamination of cytosine, which leads to C to T and G to A substitution because the deaminated deoxycytidine residues in the template are read by the Taq polymerase as deoxythymidine residues. Treatment of the template with N-glycosylase removes the deaminated cytosine from the template; a strand break then occurs through a hydrolysis reaction. The errors are therefore not incorporated into the template. Once the PCR amplifications have been carried out, the PCR products can be sequenced. If there are enough molecules, then the PCR products may be directly sequenced, however, when analyzing ancient DNA it is standard practice to subclone
204
Analytical Techniques in DNA Sequencing
the PCR products and sequence several different molecules.21,26–28 This allows detection of errors introduced in the PCR products during the amplification that have been introduced either because of template damage or infidelity of the Taq polymerase enzyme. Another critical aspect of the subcloning of the PCR products is that it allows mixtures to be detected. Even with all the precautions and controls in place, it is still not uncommon to detect products from more than one source, endogenous DNA (one hopes!) along with contaminating sequences. The problems of contamination are particularly acute when working with hominid remains as contamination from modern humans is very difficult to eliminate.21,26,27
AUTHENTICATION The measures that are required to satisfy researchers that they have in fact analyzed ancient DNA rather than some contamination are numerous. In addition to the care and the negative controls that are included in the extraction and amplification procedures, there are other factors that must be considered. These include the appropriate behavior of the DNA; for example, if large amplicons several hundred base pairs (bp) long can be generated, then the results should be treated with suspicion. Also as progressively shorter PCR products are generated, then the amount of PCR product should increase, because the number of small molecules should always be greater than the number of large molecules.26 Table 9.1 lists the steps that are required before recovered DNA can be considered to be ancient DNA rather than contamination. One of the most important controls is that the work should be repeated in a second laboratory. This is particularly true when dealing with hominid remains, which are much more prone to contamination.
TABLE 9.1 Steps That Should, When Possible, Be Included in the Analysis of Ancient Material Preliminary assessment Thermal age Morphological preservation Amino acid racemization Collagen composition Extraction, amplification, and analysis Cleaning of bone surface Multiple extractions in an environment free of contaminating DNA Appropriate behavior of the PCR reactions Multiple PCR amplifications Subcloning of PCR products and sequencing of several individual products Independent analysis in a second laboratory Establishing that the results are phylogenetically viable
Ancient DNA
205
HV I
HV II
mtDNA 16,569 bp
SNP
FIGURE 9.3 The human mitochondrial genome is composed of 16,569 nucleotides; there are two highlighted regions of the molecule called the hypervariable regions I and II. These have a higher rate of mutation than the rest of the molecule and provide a relatively compact area to analyze in order to assess differences between individuals. Around the rest of the molecule are sites, referred to as SNPs (single nucleotide polymorphisms), that are very useful for reconstructing the geneology of the molecule. When analyzing ancient DNA the SNPs are more difficult to analyze than the hypervariable regions as they are dispersed throughout the genome (there are many more SNPs than the ones shown). When looking at differences between rather than within species, more slowly evolving regions of DNA are commonly used, in particular the regions that encode for the cytochrome b, 12S and 16S genes.
A final verification should be that the results make sense phylogenetically. Although this criterion can be contentious in some cases, there are other cases where it is clearly applicable; if the analysis is of, for example, a mammoth, the sequence should look more similar to known relatives such as the elephants than to more distant relations. This is unfortunately not applicable when handling ancient human remains, as any contamination is likely to be from modern day humans.
TARGET LOCI When analyzing ancient DNA, only one locus has so far proved to be very useful. This is the mitochondrial genome (mtDNA). There are two main reasons mtDNA has been the loci of choice when dealing with ancient material. First, it is present in at high copy number; there are approximately 500 to 1000 copies of the mitochondrial genome in each cell compared to two copies of the nuclear genome (which may be different from each other in any given individual).29 The large number of molecules increases the probability of enough DNA being present in an archaeological sample to allow a successful analysis. It also has the advantage when it is used to compare divergent populations that nucleotide substitutions occur frequently (relative to the nuclear genome), particularly in two regions termed the hypervariable regions I and II (HV I and HV II; Figure 9.3), and therefore differences between separated populations accumulate rapidly. It is also maternally inherited, which allows the genealogy of the mtDNA genome to be interpreted without having to account for recombination.
206
Analytical Techniques in DNA Sequencing
Analysis of the hypervariable regions has proved powerful when examining, evolutionarily speaking, recent events such as the relationship of modern humans and Neanderthals (see below). When examining more distant events, then more slowly evolving regions of the mitochondrial genome can be utilized. Three loci that are commonly used are the 12S and 16S rRNA genes and the cytochrome b coding region. There are limitations with only using one locus when examining the genetic relationships between different populations as all loci individually are prone to chance events, such as genetic drift, which may change their frequencies in a way that is not reflective of the changes occurring at a population level. One way to increase the powers of ancient DNA analysis would be to analyze more loci. However, only the mitochondrial loci occur in multiple copies and in most cases there is very little chance of analyzing nuclear genetic material. So it remains a limitation of the studies. Some of the fauna recovered from permafrost does offer the potential for examining nuclear loci. Single copy nuclear genes from both Alaskan and Siberian mammoths have been successfully analyzed,30 demonstrating that the potential exists for analysis of nuclear as well as mitochondrial genomes.
APPLICATIONS OF ANCIENT DNA ANALYSIS With an increased awareness of the pitfalls of ancient DNA analysis along with a better understanding of the process of DNA degradation, a number of studies have now been published that satisfy the criteria that are needed before the results of any ancient DNA analysis can be widely accepted. The second half of this chapter examines some of the applications of ancient DNA analysis. The first of these concerning the relationship of the Neanderthals to the modern European population is discussed in some detail to give an overview of the processes that are important in ancient DNA analysis. Brief overviews of work undertaken in different areas are then discussed.
HUMAN EVOLUTION
AND THE
PLACE
OF THE
NEANDERTHALS
Background The relationship of the Neanderthals to modern humans has been the source of heated debate ever since the first specimen was identified as a Neanderthal after it was recovered from the Feldhofer Cave in 1856 (specimens had been discovered in Belgium and Gibraltar before this but only identified as Neanderthals after the Feldhofer specimen). Neanderthals had occupied Europe for hundreds of thousands of years; 40,000 years ago the first anatomically modern humans entered Europe and approximately 10,000 years after the first modern humans entered Europe the last Neanderthals disappeared. The mechanism of the Neanderthal extinction has been the source of much argument, with several competing hypotheses. The multiregional hypothesis advocates that an ancestral population of Homo erectus (that spread around the world from Africa around 1 million years ago) evolved into modern humans regionally, with gene flow between geographically distinct populations. The out-of-Africa model proposes that modern humans evolved in Africa around 150,000
Ancient DNA
207
years ago and subsequently spread throughout the world, replacing all earlier hominid species, including the Neanderthals. The intermediate hybridization and assimilation hypotheses predict that the modern European population is a product of mixing between the Neanderthals and the modern humans from Africa. Studying the Neanderthal mtDNA pool directly has allowed questions regarding the genetic composition of the Neanderthals to be addressed. Samples Mitochondrial DNA now been successfully extracted and analyzed from three Neanderthal specimens recovered from the Feldhofer Cave in Germany, the Mezmaiskaya Cave in the Caucasus Mountains, and the Vindija Cave in Croatia.21,27,28 All these samples had the benefit of dating from the end of the period of Neanderthal occupation, approximately 40,0000 years for the Feldhofer and Vindija samples and 30,000 years for the Mezmaiskaya sample. All three samples were also from areas of relatively low average temperature.6 Other Neanderthal samples that had been examined before from warmer areas in southern Europe had displayed too much diagenetic change to justify DNA analysis.10 Despite having only three sequences that are separated geographically and temporally it has been possible to examine some aspects of the Neanderthal mtDNA pool. DNA Extraction and Sequence Analysis In all three successful extractions very similar DNA extraction protocols were used. Bone material was used in all three cases; the procedure used is shown in Figure 9.4. The DNA extracts were amplified using primers that amplified regions of the mitochondrial hypervariable region that were then subcloned into a plasmid vector. Multiple clones from separate PCRs were sequenced. The results of the sequencing of the Mezmaiskaya Neanderthal are shown in Figure 9.5. The consensus sequence is derived by selecting only the substitutions and insertions that occur in the majority of the clones from at least two independent reactions. There are a number of substitutions that occur in only one cloned PCR product, which can be explained as either due to errors introduced through the infidelity of the Taq DNA polymerase or due to damage in the DNA template. The analysis of the Mezmaiskaya Neanderthal was unusual in that enough PCR product could be generated to allow direct sequencing, but subcloning and sequencing the PCR products was still necessary to detect errors introduced during the amplification, as well as the presence of more than one type of mtDNA (endogenous and also modern contaminating mtDNA). The Neanderthal sequences have been analyzed in a number of different ways. The Cambridge Reference Sequence (CRS) acts as a reference sequence for all mtDNA analysis, and comparison to this indicated the degree of variation in comparison to modern sequences. The information displayed in Figure 9.6 is in comparison to the CRS. The Feldhofer, Mezmaiskaya, and Vindija Neanderthals contain 27, 22, and 22 substitutions relative to the CRS, respectively; all of them contained one insertion at position 16,263 (see Figure 9.1). The three Neanderthal sequences share 18 substitutions and one insertion with respect to the CRS.
208
Analytical Techniques in DNA Sequencing
Removal of the bone surface: Grind/sand + soak in 10% bleach for 30 min
UV irradiation of the bone for 1 hour on all surfaces
Powdering of the bone sample using a mechanical grinder
Incubation of the bone powder in 0.5 M EDTA, 100 g proteinase k, 0.1% sarkosyl 56°C, 48 h Phenol chloroform extraction of the bone sample
Washing and concentration of the extract using centricon –30 Check for PCR inhibition Further purification of extract with glass milk
FIGURE 9.4 Flow diagram showing the methodology that is commonly used for extracting DNA from bone samples, including the extraction from the Mezmaiskaya Neanderthal. With the Mezmaiskaya Neanderthal bone no PCR inhibition was detected with the extracted sample after the centricon-30 purification stage. Therefore the final clean using glass milk (or other related method, e.g., Höss and Pääbo50) was not carried out.
CRS Direct 1 P1 P2 P3 Direct 2 577.1 557.2 581.2 581.3 Mezmaiskaya
1 6 2 2 3 C T T T T T T T T T C . A T T A T C C C C T
1 6 0 8 6 T C C C C
1 6 1 1 8 G . . . A
1 6 1 2 9 G A A A A
1 6 1 3 9 A T T T T
1 6 1 4 8 C T T T T
1 6 1 5 6 G A A A A
1 6 1 6 9 C T T T T
1 6 1 8 2 A C C C C
1 6 1 8 3 A C C C C
1 6 1 8 9 T C C C C
1 6 2 0 9 T C C C C
1 6 2 3 0 A G G G G G G G G G G
1 6 2 3 4 C T T T T T T T T T T
1 6 2 4 3 T . . . . . . . . C .
1 6 2 4 4 G A A A A A A A A A A
1 6 2 5 0 C . . . . . . T . . .
1 6 2 5 6 C A A A A A A A A A A
1 6 2 6 1 C
1 6 2 6 2 C
1 6 2 6 3.1 -
1 6 2 7 8 C
1 6 2 9 9 A
1 6 3 1 1 T
1 6 3 2 0 C
1 6 3 4 4 C
1 6 3 6 2 T
1 6 3 6 5 C
1 6 3 9 3 C
. . . . T . . . .
T T T T T T T T T
A A A A A A A A A
T T T T T T T T T
G G G G G G
C C C C C C
T T T T T T
T T T T T T
C C C C C C
. . . . T .
. T . . . .
FIGURE 9.5 DNA sequences of the PCR fragments obtained by direct sequencing (Direct 1 and 2) are shown along with several cloned PCR products generated during the analysis of the Neanderthal from Mezmaiskaya Cave. The sequence that could be duplicated in a second laboratory is shown in bold within the compiled Mezmaiskaya sequence.
Ancient DNA
209
96
10 modern humans
90 85
Mezmaiskaya Neanderthal Feldhofer Neanderthal Vindija Neanderthal 2 chimpanzees
FIGURE 9.6 Phylogenetic analysis of Neanderthal and modern human DNA. A phylogenetic tree produced using parsimony analysis, showing the relationship between the three Neanderthals and a selection of 10 modern humans. The result is typical of several data sets and is also similar to that found when using other phylogenetic tree-building algorithms. The numbers on the branches indicate the strength of the different branches (100 is the highest possible value).
The data have been analyzed using phylogenetic analysis. The results of this have all come to the same conclusion, using methods that incorporated maximum-likelihood, parsimony, and distance analyses. All the different types of analysis identify the Neanderthal and modern human sequences as different lineages (Figure 9.5). That the three sequences share a large number of substitutions and an insertion and that they all group together after phylogenetic analysis act as a powerful means of verifying that the three sequences are from the Neanderthals and are not a product of some peculiar contamination or a result of amplifying highly damaged DNA. The Age of Divergence The number of substitutions that have accumulated in modern humans and the Neanderthal mtDNA lineages since they split has be used to estimate the time of the divergence using the substitution rate as a molecular clock. The genetic distance between modern and Neanderthal mtDNA was used to date the split between the modern humans and the Neanderthals mtDNA and also to estimate the age of the Neanderthal mtDNA lineage.31 The split between the modern human and Neanderthal lineages has been dated to approximately 600,000 years (365,000 to 853,000) while the age of the most recent common ancestor of the eastern and western Neanderthals is 151,000 to 352,000 years ago. Using the same data modern humans are estimated to have had a common ancestor 106,000 to 246,000 years ago28 (Figure 9.7).
210
Analytical Techniques in DNA Sequencing
0
Neanderthals
Modern humans
100 200 300 YBP (000s)
400 500 600 700 800 900
FIGURE 9.7 Using the mitochondrial DNA as a molecular clock, it has been possible to date the times (years before present) of the most recent ancestors of modern humans, Neanderthals, and also the common ancestor of modern humans and Neanderthals (the 95% confidence intervals are shown by the vertical lines).
Neanderthal Diversity The three Neanderthals have provided an indication of the diversity that is present in the Neanderthal lineage. Using only three specimens there is a 50% probability that the deepest split in the Neanderthal lineage has been detected (probability of sampling the deepest split = n – 1/n + 1, where n is the number of sampled specimens). It is therefore unlikely that a Neanderthal specimen will be found that is highly diverse from the three specimens analyzed to date. The three Neanderthals differ at 8 ± 3.46 positions, which is similar to the levels of diversity that are found in modern humans. This contrasts to the high levels of diversity found in chimpanzees and gorillas, which have much greater levels of sequence diversity.21 The low levels of diversity found in modern humans have been interpreted as reflecting a rapid growth of a small population,32 indicating that the demography of the Neanderthals could have been similar to that of modern humans. Admixture The analyses undertaken on the samples to date have shown that the Neanderthal and modern mtDNA form distinct lineages and that the modern mtDNA pool is derived entirely from the ancestral modern humans. The absence of mtDNA from the Neanderthal lineage in the modern gene pool does not exclude the possibility that Neanderthals and modern humans may have interbred. Most of the lineages that were present
Ancient DNA
211
in the modern human population 30,000 years ago (approximately 1500 generations) will have been lost through the process of genetic drift.33 This point is further illustrated by the fact that most of the lineages that are present in the present European population can be attributed to lineages that date to less than 20,000 years ago.34
PHYLOGENY AND POPULATION GENETICS USING EXTINCT ANIMAL POPULATIONS Since the first report of ancient DNA analysis from an extinct animal, the quagga,24 studies have been undertaken on several species. These include among others the marsupial wolf,35,36 the saber-tooth cat,37 the moa38,39 and the moa-nalo,40 the cave bear,41–43 and the giant ground sloth.4 The main aim of these studies has been to examine the evolutionary relationship between extinct and extant taxa. The cave bear studies have an advantage over most other types of study that there are a lot of remains available and a number of these are from areas of low temperatures and therefore the potential for DNA survival is greater. Given the potential for extracting ancient DNA, the cave bears offer the possibility of studying populations rather than isolated individuals, and therefore features of the population such as the diversity prior to periods of extinction and the differentiation of populations in response to climatic change can be addressed. It has also been suggested that the information from some of the studies should influence conservation strategies,42 although there is no universal consensus on how the data should be incorporated into policy.44 One of the most striking studies carried out on ancient DNA involves the complete mitochondrial sequencing of two New Zealand moa genera.39 The complete sequencing improved the precision of the phylogenetic relationships among ratite birds (including ostrich, kiwi, moa, rhea, cassowary, and elephant bird). The data from the extinct and extant samples were used to date the age of the divergence and speciation events of the ratite taxa to the Late Cretaceous. This date supported the hypothesis that the breakup of the Gondwana continent (in the Cretaceous) was the event that led to the physical barriers between ratite populations and therefore acted as the catalyst for the proliferation of ratite species. The data by providing a new perspective on Cretaceous biogeography indicate the potential value of using ancient DNA in conjunction with extant taxa to resolve important biogeographical issues.
THE ORIGINS
AND
SPREAD
OF
AGRICULTURE
The shift of human lifestyles from hunter-gatherers to agriculturists over the last 10,000 years has been dramatic. In keeping with the importance of this transition, the origin and spread of agriculture have been important areas of study for archaeology in the last century. Molecular genetics has acted as another source of information in this multidisciplinary research area and has been used to address questions regarding both the domestication of animals and the development of crops. Molecular genetics can address two aspects of animal domestication and crop development. Did the domestication/development of particular species occur as a single discrete event or did they occur several times, and what were the wild progenitors of the modern breeds and varieties?
212
Analytical Techniques in DNA Sequencing
One of the most comprehensive studies examining domestication undertaken to date45 examined the origin of European cattle. By analyzing 392 extant animals from Europe, Africa, and the Near East along with 4 extinct wild British oxen, the extinct British oxen could be excluded as a likely source of the domesticated European cattle. The genetic data from the extant populations suggest that the Near East is a much more likely source of the European cattle stock. The data again illustrate the power of combining the analysis of extant and extinct populations. Earlier ancient DNA studies on European cattle46 had suggested that a recent expansion of European cattle from a diverse wild progenitor species had occurred. In the course of similar research examining the domestication of the domestic horse, several Pleistocene horses were examined and the variation found within overlapped with the variation found in modern horses, indicating that much of the mtDNA diversity entered the domestic horse gene pool early on in domestication.47 The development of crop plants, corn and barley in Europe and the Near East, rice in the Far East, and corn in the Americas, was an extremely important phase in the transition from hunter-gatherer to agricultural lifestyles. As with the examination of livestock, the histories of the development of these crops have received much attention. The seeds offer a potential source of DNA and are relatively commonly found at archaeological sites; desiccated and charred remains have yielded ancient DNA (see Brown20). Analysis of remains from different sites in Europe has provided some information on the timing of some of the key stages in the development of wheat, in particular the first appearances of hexaploid wheat.48
FUTURE DIRECTIONS FOR ANCIENT DNA The realization that ancient DNA is very unlikely to survive longer than 100,000 years means that efforts should now be focused on samples that fall within this time interval, in particular, samples recovered from environments with relatively low average temperatures where there is a higher likelihood that the ancient DNA will have survived. Further advances in understanding the chemistry of the substrates will also lead to the possibility of improving the efficiency of ancient DNA extractions and opening new types of samples to analysis; the successful analysis of coprolites is one example where this has already occurred.18,19 There is great potential for continued studies of extinct populations that should provide insights into population dynamics and diversity over time. The Neanderthals of Northern Europe and the Caucasus also offer the potential to study the population genetics of this extinct hominid. The Pleistocene megafauna remains that have been recovered from the arctic permafrost along with remains from high-altitude caves offer important sources of material that are amenable to population-level studies. The material recovered from permafrost, in addition to the relatively large number of samples available, also offers the potential for examining more informative nuclear loci.49 Finally, an important aspect of ancient DNA analysis is that the improved technical procedures that have been made possible through a better understanding of the process of degradation of ancient DNA will continue to feed into and enhance other fields including forensics and conservation biology, where small amounts of DNA from problematic substrates are also commonly encountered.
Ancient DNA
213
REFERENCES 1. Saiki RK, Scharf S, Faloona F, Mullis KB, Horn GT, Erlich HA, Arnheim N. Enzymatic amplification of beta-globin genomic sequences and restriction site analysis for diagnosis of sickle-cell anaemia. Science 230, 1350 –1354, 1985. 2. Lindahl T. Instability and decay of the primary structure of DNA. Nature 362, 709–715, 2003. 3. Pääbo S, Irwin DM, Wilson AC. DNA damage promotes jumping between templates during enzymatic amplification. J Biol Chem 265, 4718–4721, 1990. 4. Höss M, Jaruga P, Zastawny TH, Dizdaroglu M, Pääbo S. DNA damage and DNA sequence retrieval from ancient tissues. Nucleic Acids Res 24, 1304–1307, 1996. 5. Hofreiter M, Jaenicke V, Serre D, von Haeseler A, Pääbo S. DNA sequences from multiple amplifications reveal artifacts induced by cytosine deamination in ancient DNA. Nucleic Acids Res 29, 4793–4799, 2001. 6. Smith CI, Chamberlain AT, Riley MS, Cooper A, Stringer CB, Collins MJ. Not just old but old and cold? Nature 410, 771–777, 2001. 7. Ovchinnikov IV, Gotherstrom A, Romanova GP, Kharitonov VM, Linde K, Goodwin W. Not just old but old and cold? M Reply. Nature 410, 772–772, 2001. 8. Hagelberg E, Bell LS, Allen T, Boyde A, Jones SJ, Clegg JB. Analysis of ancient bone DNA—techniques and applications. Philos Trans R Soc B 333, 399–407, 1991. 9. Poinar HN, Höss M, Bada JL, Pääbo S. Amino acid racemization and the preservation of ancient DNA. Science 272, 864–866, 1996. 10. Cooper A, Poinar HN, Pääbo S, Radovcic J, Debenath A, Caparros M, Barroso-Ruiz C, Bertranpetit J, Nielsen-Marsh C, Hedges REM, Sykes B. Neandertal genetics. Science 277, 1021–1024, 1997. 11. Poinar HN, Stankiewicz BA. Protein preservation and DNA retrieval from ancient tissues. Proc Natl Acad Sci USA 96, 8426–8431, 1999. 12. Golenberg EM, Giannasi DE, Clegg MT, Smiley CJ, Durbin M, Henderson D, Zurawski G. Chloroplast DNA-sequence from a Miocene magnolia species. Nature 344, 656–658, 1990. 13. Desalle R, Gatesy J, Wheeler W, Grimaldi D. DNA-sequences from a fossil termite in Oligomiocene amber and their phylogenetic implications. Science 257, 1933–1936, 1992. 14. Cano RJ, Poinar HN, Pieniazek NJ, Acra A, Poinar GO. Amplification and sequencing of DNA from a 120–135-million-year-old weevil. Nature 363, 536–538, 1993. 15. Woodward SR, Weyand NJ, Bunnell M. DNA-sequence from Cretaceous period bone fragments. Science 266, 1229–1232, 1994. 16. Wang HL, Yan ZY, Jin DY. Reanalysis of published DNA sequence amplified from cretaceous dinosaur egg fossil. Mol. Biol. Evol. 14, 589–591, 1997. 17. Stankiewicz BA, Poinar HN, Briggs DEG, Evershed RP, Poinar GO. Chemical preservation of plants and insects in natural resins. Proc R Soc Lond B Biol 265, 641–647, 1998. 18. Poinar HN, Hofreiter M, Spaulding WG, Martin PS, Stankiewicz BA, Bland H, Evershed RP, Possnert G, Pääbo S. Molecular coproscopy: dung and diet of the extinct ground sloth Nothotheriops shastensis. Science 281, 402–406, 1998. 19. Poinar HN, Kuch M, Sobolik KD, Barnes I, Stankiewicz AB, Kuder T, Spaulding WG, Bryant VM, Cooper A, Pääbo S. A molecular analysis of dietary diversity for three archaic Native Americans. Proc Natl Acad Sci USA 98, 4317–4322, 2001. 20. Brown TA. (1999) How ancient DNA may help in understanding the origin and spread of agriculture. Philos Trans R Soc B 354, 89–97, 1999.
214
Analytical Techniques in DNA Sequencing
21. Krings M, Capelli C, Tschentscher F, Geisert H, Meyer S, von Haeseler A, Grossschmidt K, Possnert G, Paunovic M, Pääbo S. A view of Neandertal genetic diversity. Nat Genet 26, 144–146, 2000. 22. Handt O, Krings M, Ward RH, Pääbo S. The retrieval of ancient human DNA sequences. Am J Hum Genet 59, 368–376, 1996. 23. von Wurmb-Schwark N, Higuchi R, Fenech AP, Elfstroem C, Meissner C, Oehmichen M, Cortopassi GA. Quantification of human mitochondrial DNA in a real time PCR. Forensic Sci Int 126, 34–39, 2002. 24. Higuchi R, Bowman B, Freiberger M, Ryder OA, Wilson AC. DNA-sequences from the Quagga, an extinct member of the horse family. Nature 312, 282–284, 1994. 25. Pääbo S. Molecular-cloning of ancient Egyptian mummy DNA. Nature 314, 644–645, 1985. 26. Handt O, Richards M, Trommsdorff M, Kilger C, Simanainen J, Georgiev O, Bauer K, Stone A, Hedges R, Schaffner W, Utermann G, Sykes B, Pääbo S. Moleculargenetic analyses of the Tyrolean Ice Man. Science 264, 1775–1778, 1994. 27. Krings M, Stone A, Schmitz RW, Krainitzki H, Stoneking M, Pääbo S. Neandertal DNA sequences and the origin of modern humans. Cell 90, 19–30, 1997. 28. Ovchinnikov IV, Gotherstrom A, Romanova GP, Kharitonov VM, Liden K, Goodwin W. Molecular analysis of Neanderthal DNA from the northern Caucasus. Nature 404, 490–493, 2000. 29. Robin ED, Wong R. Mitochondrial-DNA molecules and virtual number of mitochondria per cell in mammalian-cells. J Cell Physiol 136, 507–513, 1988. 30. Greenwood AD, Capelli C, Possnert G, Pääbo S. Nuclear DNA sequences from late Pleistocene megafauna. Mol Biol Evol 16, 1466–1473, 1999. 31. Tamura K, Nei M. Estimation of the number of nucleotide substitutions in the control region of mitochondrial DNA in humans and chimpanzees. J Mol Evol 10, 512–526, 1993. 32. Harpending HC, Batzer MA, Gurven M, Jorde LB, Rogers AR, Sherry ST. Genetic traces of ancient demography. Proc Natl Acad Sci USA 95, 1961–1967, 1998. 33. Nordborg M. On the probability of Neanderthal ancestry. Am J Hum Genet 63, 1237–1240, 1998. 34. Richards M, Macaulay V, Hickey E, Vega E, Sykes B, et al. Tracing European founder lineages in the near eastern mtDNA pool. Am J Hum Genet 67, 1251–1276, 2000. 35. Thomas RH, Schaffner W, Wilson AC, Pääbo S. DNA phylogeny of the extinct marsupial wolf. Nature 340, 465–467, 1989. 36. Krajewski C, Buckley L, Westerman M. DNA phylogeny of the marsupial wolf resolved. Proc R Soc Lond B Biol 264, 911–917, 1997. 37. Janczewski DN, Yuhki N, Gilbert DA, Jefferson GT, O’Brien SJ. Molecular phylogenetic inference from saber-toothed cat fossils of Rancho-la-brea. Proc Natl Acad Sci USA 89, 9769–9773, 1992. 38. Cooper A, Mourerchauvire C, Chambers GK, von Haeseler A, Wilson AC, Pääbo S. Independent origins of New Zealand moas and kiwis. Proc Natl Acad Sci USA 89, 8741–8744, 1992. 39. Cooper A, Lalueza-Fox C, Anderson S, Rambaut A, Austin J, Ward R. Complete mitochondrial genome sequences of two extinct moas clarify ratite evolution. Nature 409, 704–707, 2001. 40. Sorenson MD, Cooper A, Paxinos EE, Quinn TW, James HF, Olson SL, Fleischer RC. Relationships of the extinct moa-nalos, flightless Hawaiian waterfowl, based on ancient DNA. Proc R Soc Lond B Biol 266, 2187–2193, 1999.
Ancient DNA
215
41. Hanni C, Laudet V, Stehelin D, Taberlet P. Tracking the origins of the cave bear (Ursus spelaeus) by mitochondrial-DNA sequencing. Proc Natl Acad Sci USA 91, 12336–12340, 1994. 42. Leonard JA, Wayne RK, Cooper A. Population genetics of Ice Age brown bears. Proc Natl Acad Sci USA 97, 1651–1654, 2000. 43. Loreille O, Orlando L, Patou-Mathis M, Philippe M, Taberlet P, Hanni C. Ancient DNA analysis reveals divergence of the cave bear, Ursus spelaeus, and brown bear, Ursus arctos, lineages. Curr Biol 11, 200–203, 2001. 44. Pääbo S. Of bears, conservation genetics, and the value of time travel. Proc Natl Acad Sci USA 97, 1320–1321, 2000. 45. Troy CS, MacHugh DE, Bailey JF, Magee DA, Loftus RT, Cunningham P, Chamberlain AT, Sykes BC, Bradley DG. Genetic evidence for near-eastern origins of European cattle. Nature 410, 1088–1091, 2001. 46. Bailey JF, Richards MB, Macaulay VA, Colson IB, James IT, Bradley DG, Hedges REM, Sykes BC. Ancient DNA suggests a recent expansion of European cattle from a diverse wild progenitor species. Proc R Soc Lond B Biol 263, 1467–1473, 1996. 47. Vila C, Leonard JA, Gotherstrom A, Marklund S, Sandberg K, Liden K, Wayne RK, Ellegren H. Widespread origins of domestic horse lineages. Science 291, 474–477, 2001. 48. Schlumbaum A, Jacomet S, Neuhaus JM. Coexistence of tetraploid and hexaploid naked wheat in a neolithic lake dwelling of central Europe: Evidence from morphology and ancient DNA. J Archaeol Sci 25, 1111–1118, 1998. 49. Greenwood AD, Castresana J, Feldmaier-Fuchs G, Pääbo S. A molecular phylogeny of two extinct sloths. Mol Phylogenet Evol 18, 94–103, 2001. 50. Höss M, Pääbo S. DNA extraction from Pleistocene bones by a silica based purification method. Nucleic Acids Res 21, 3913–3914, 1993. 51. Lindahl T. The Croonian Lecture, 1996: Endogenous damage to DNA. Philos Trans R Soc Lond B Biol Sci 351, 1529–1538, 1996.
10
ForensicDNASequencing Terry Melton and Victor W. Weedn
CONTENTS Introduction............................................................................................................217 Historical Perspective ............................................................................................218 Special Forensic Considerations............................................................................219 Forensic mtDNA Applications ..............................................................................221 Forensic mtDNA Sequencing................................................................................222 Forensic mtDNA Sequence Interpretation ............................................................225 Mitochondrial DNA Heteroplasmy .......................................................................228 Mixtures .................................................................................................................229 References..............................................................................................................230
INTRODUCTION DNA sequencing underlies all forms of forensic DNA testing, historically permitting description of the genomic variation of all typing systems. Routine DNA typing was originally performed using fragment sizing for restriction fragment length polymorphisms (RFLPs) and now is performed by fragment sizing for short tandem repeats (STRs). These methods are powerful, rapid, and relatively inexpensive. Sequencing protocols in forensic casework are applied exclusively in mitochondrial DNA (mtDNA) analysis1–5 in those special cases where routine DNA typing is not helpful—mostly commonly for hairs and skeletal remains. Although the STR loci could be sequenced, fragment length analysis for each locus is considered a more practical and cost-effective DNA typing technology than sequence analysis. The basic instrumentation is the same, reagent costs are greater for sequencing, and sequence analysis is not as intuitive, facile, or fast. Moreover, STR analysis permits multiplexing many genetic loci simultaneously, where sequencing does not. Presumably, if sequencing technology became sufficiently fast and inexpensive, it might compete with other forensic tests. MtDNA is the most polymorphic region within the human genome and unlike other regions (with the arguable exception of the human leukocyte antigen [HLA] region) can by itself (in isolation) be used for forensic identity testing. However, as the polymorphisms are within a single region that can be sequenced, they are not genetically independent. Thus, the frequency rates of the mtDNA polymorphic sites cannot be multiplied together. MtDNA haplotype profiles are not as powerful as current STR multiplex profiles. The high discriminatory rates of RFLP and STR 217
218
Analytical Techniques in DNA Sequencing
analysis are achieved precisely because the frequency rates of the disparate loci are independent and the frequencies can be multiplied together. Unlike nuclear DNA, mtDNA does not contain significant repetitive DNA sequences; instead, variation is present as single nucleotide polymorphisms and interrogation cannot be based on simple fragment sizing like other forensic DNA markers. Hybridization assays can capture this sequence information, but sequencing has generally been preferred for mtDNA analysis to efficiently capture the large range of possible polymorphic sites. Nonetheless, dot/blots were originally used by Mark Stoneking to perform in mtDNA analysis. In Europe a multiplex solid-phase fluorescent minisequencing system was developed to rapidly survey ten substitution polymorphisms and two length polymorphisms in HV1 and HV2.6 More recently, a rapid hybridization assay using 33 immobilized probes has been commercialized by Roche Molecular Systems as the “Linear Array Mitochondrial DNA HVI/HVII Region—Sequence Typing Kit.” These new hybridization assays are intended to be used as screening tools, rather than replace current sequencing methods. Such systems capture most, but not all polymorphic sites and thus sacrifice an already limited discriminatory potential. Also, dot/blots are problematic with respect to mixtures and heteroplasmy, whereas sequencing generates information that helps to interpret the quality of the data that is difficult to assess in a dot/blot assay; e.g., it is possible to use neighboring peaks to interpret a given sequencing peak. Furthermore, reverse sequencing can verify the sequencing results. Last, shoulder regions are themselves polymorphic, complicating probe assays. Even pyrosequencing assays involving short stretches of DNA sequence of up to 100 bp in length7 have been used. Nonetheless, when these screening methods fail to make an exclusion, full-length DNA sequencing is performed to confirm the match and derive statistics from a full database search of the complete profile. Hybridization assays may also be used to augment the mtDNA sequence information by capturing polymorphic sites away from the area of sequencing.
HISTORICAL PERSPECTIVE Commercial entities dedicated to forensic DNA testing (Forensic Science Associates, Lifecodes, Cellmark Diagnostics) opened their doors to casework in 1986 and 1987 and government laboratory testing began thereafter (the FBI began casework in December of 1988 and Virginia began the first state crime lab testing in March of 1989). Although sequencing was performed for research and validation purposes from the inception of forensic DNA typing, it was only later that sequencing was used as the routine analytic casework technique, in the specific instance of mitochondrial analysis. Mitochondrial DNA analysis began in academic settings and a few government laboratories within a few years after the inception of nuclear forensic DNA typing. Much of the early groundwork and many of the investigators, such as Mark Stoneking and Svante Pääbo, come from the Molecular Evolution Laboratory of the late Allan Wilson’s laboratory at the University of California at Berkeley during the 1970s and 1980s. MtDNA sequencing was first used in a forensic application by Mary Claire-King and Chuck Ginther in the late 1980s to reassociate family kindred
Forensic DNA Sequencing
219
of the “disappeared” in Guatemala. The first case of mtDNA victim identification was performed by Mark Stoneking to identify a body in the southwestern U.S. in 1990. Erika Hagelberg at Cambridge used the technique in 1991 to identify a Nazi war criminal, Joseph Mengele. Victor Weedn, Deborah Fisher, Rhonda Roby, and Mitchell Holland at the Armed Forces DNA Identification Laboratory (AFDIL) then began to apply the technique routinely and systematically to skeletal remains of the war dead; AFDIL first used mtDNA sequencing in a case for the first Persian Gulf War in 1991. The Defense Science Board (DSB), led by Joshua Lederberg, reviewed the mtDNA identification of remains performed by the AFDIL. The DSB concluded that the methodology was a sound method of performing such identifications and that adequate quality assurance methods were employed to assure public confidence in the results. By the mid-1990s only AFDIL, the FBI, and a commercial lab, LabCorps, were performing forensic mtDNA sequencing casework in the U.S. In 1998, Mitotyping Technologies, LLC, opened as the only commercial laboratory devoted to this activity. Celera used high-throughput sequencing techniques to assist identifications of the World Trade Center disaster. Mitochondrial DNA is being performed by more public and private laboratories, but most crime laboratories find that it is too expensive, time-consuming, and specialized to perform. In 2003, the FBI sponsored the development of four regional laboratories.
SPECIAL FORENSIC CONSIDERATIONS In no other DNA sequencing effort is the outcome as fraught with potential pitfalls or rewards as in forensic testing. Forensic DNA analysis may result in a criminal charge, exonerate the accused, identify a missing individual, open the door to solving cold cases, or begin postconviction relief for the falsely incarcerated. When such analyses can so profoundly affect the lives of defendants and victims, both reliability of method and quality control assume orders of magnitude more importance than in a nonforensic approach to DNA sequencing. Most research laboratories are not prepared to handle forensic casework. Forensic testing differs from clinical testing in a number of significant ways. The evidentiary specimens unlike clinical specimens are not pristine, but instead have been exposed to the environment for various lengths of time. Many forensic samples have a history of severe environmental insult, with exposure to cycles of heat and cold, moisture, ultraviolet radiation, and acidic soil. The evidentiary specimen may be minute and is nonreplenishable; thus retesting may not be possible. Last, the questions to be addressed are usually different as the clinical test will be for the presence or absence or quantity of a given analyte whereas the forensic test is to demonstrate the uniqueness of the specimen and its linkage to the crime. Of course, forensic testing carries the potential that it might be used in a legal proceeding as evidence and receive judicial scrutiny. One implication is that documentation is paramount. The documentation begins with chain-of-custody documentation that accounts for the custody of the evidentiary specimen from receipt through testing. Identification of the source of the reference specimens as being of the person represented must specifically be documented.
220
Analytical Techniques in DNA Sequencing
TABLE 10.1 Examples of Validation Studies Performed in Forensic Laboratories Reproducibility of known samples (cell lines and NIST standards) Assessment of mixtures (detection of heteroplasmy and mixed templates) Lower-level sensitivity of instrumentation and chemistry Accidental cross-species detection (primer specificity) Behavior of compromised samples (dirt, heat, light, acid soil) Performance using different tissue types: hair, bone, blood, saliva, organ, fingernails, etc. Cleaning of samples (satisfactory removal of deliberate contamination) Interinstrument variation (comparison of multiple sequencers and thermocyclers) Interlaboratory sample exchanges (retest samples analyzed by another lab) External review of standard operating procedures by outside experts Testing of all new reagents, equipment, and methods prior to introduction in casework
The procedures performed must also be well documented. The procedures must also have been validated prior to casework in the given laboratory, even though others have previously scientifically validated the procedure. Internal validation studies that assess the sensitivity, accuracy, and reproducibility of a laboratory’s specific analytic system with its particular instrumentation and quality guidelines must be documented. Table 10.1 shows the kinds of validation studies a forensic laboratory must perform prior to instituting forensic DNA sequencing. Forensic DNA testing laboratories must conform to quality assurance standards otherwise unparalleled in the molecular biology field. Accrediting bodies such as the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB) or the National Forensic Science Training Center (NFSTC) determine if laboratories perform testing according to their specifications. These accrediting bodies appear to be moving to ISO-based formats. Furthermore, procedural guidelines specific to mtDNA analysis have been promulgated by the FBI DNA Advisory Board (DAB) and recently modified by its Scientific Working Group on DNA Analysis Methods (SWGDAM). Although the guidelines are purportedly voluntary, they operate as de facto legal forensic evidentiary standards. These forensic standards mandate certain college-level coursework as well as rigorous on-the-job training of technicians and analysts to guarantee that personnel handling evidence are familiar with the nuances of forensic sample handling, for example, chain-of-custody and courtroom testimony. Semiannual proficiency testing is required of each analyst; the College of American Pathologists, Collaborative Testing Service and Quality Forensics sells external proficiency surveys for this purpose. Regular audits, both internal and external, investigate a laboratory’s adherence to all appropriate guidelines. Where a typical DNA sequencing laboratory would focus largely on gathering and storing DNA sequence data for its projects, only a small proportion of the forensic DNA sequencing laboratory’s effort is concerned with this. Instead, security of evidence, client confidentiality, laboratory cleanliness, prevention and tracking of contamination, data storage and preservation, file maintenance, and documentation
Forensic DNA Sequencing
221
of quality assurance and control consume at least one half of the forensic lab’s resources on a daily basis. Only samples from one case are handled at a time. A particular concern for forensic mtDNA analysis is recognition and avoidance of contamination. Typically, the analysis is performed specifically in cases where exquisite sensitivity is needed—beyond that of routine polymerase chain reaction (PCR) testing. The sensitivity of a mitochondrial analysis is one to two orders of magnitude greater than that of a nuclear DNA analysis, such that even a few skin cells from fabric may be co-extracted and co-amplified with the stain of interest. The sample preparation should be performed in space dedicated to “low copy number” specimens. Many controls and much redundancy are built into forensic protocols that would permit recognition of any contamination. Furthermore, forensic DNA sequencing laboratories frequently maintain their own DNA sequence databases, which include the sequences of their own laboratory staff personnel as well as those of all samples ever handled by the lab. These databases serve as a starting point for identifying laboratory sources of contamination that may be observed during casework.
FORENSIC mtDNA APPLICATIONS Mitochondrial DNA analysis is primarily applied in certain types of forensic cases. Specifically, mtDNA analysis is performed where nuclear DNA is unavailable (e.g., hair analysis), highly degraded (e.g., skeletal remains), present in trace quantities (e.g., fingerprint residues), and where family reference specimens are available only from distant kindred (e.g., Czar Nicholas II). Naturally shed (telogen) hairs will not usually yield sufficient nuclear DNA for typing. On the other hand, plucked hairs with hair roots are suitable for routine nuclear STR analysis. Mitochondrial DNA is generally well preserved in the medulla of the shaft, protected by the keratinous cuticle and cortex, but the nuclear DNA was destroyed during the process of epithelial cell keratinization. Shed hairs are not uncommonly found at crime scenes; the average adult has approximately 100,000 scalp hairs and loses approximately 60 to 100 hairs per day. Furthermore, pubic hairs are frequently found in cases of sexual assault. DNA will be degraded during decomposition through putrefaction by endogenous enzymes, including DNases, and through bacterial action. Nonetheless recently skeletonized remains provide plentiful nuclear DNA for routine typing. Aged bone, on the other hand, generally requires mtDNA analysis. Many mtDNA particles may be found in the hundreds to thousands of mitochondria in the cytoplasm of each cell. This high copy number of mtDNA relative to nuclear DNA is the main reason for successful DNA typing using mtDNA when nuclear DNA is unsuccessful. The enamel of teeth and the calcified matrix of dense cortical bone provide some level of protection from the elements. Some believe that the circular nature of mtDNA also provides some minor added protection from enzymatic action. As mtDNA is maternally inherited without recombinant crossover events, distant maternal relatives, in the absence of a mutation event, will have exactly matching mtDNA sequences. By contrast, identification of human remains using nuclear DNA testing, if technically possible at all, is more complex in that multiple family members
222
Analytical Techniques in DNA Sequencing
need to be compared to the missing individual and each other via assembly of a “kinship” tree. Blood, saliva, and semen are often collected off complex, dirty substrates such as clothing or bedding, or contain mixtures such as those encountered in sexual assault, and will often show these mixtures in the mtDNA sequences. Mixtures are very problematic for mtDNA analysis. Therefore, samples that can be cleaned of external contaminants prior to testing, such as hairs and bones, are the best candidates for mtDNA analysis, and rarely give mixed profiles. Nonetheless, because of the characteristic high copy number of mtDNA, mtDNA may prove to be of value in the newly burgeoning area of so-called “trace” DNA or “low copy number” (LCN) DNA testing. It is now known that admixed with the traditional fingerprint residues are traces of DNA. Pushing the sensitivity of traditional PCR techniques can permit LCN typing of fingerprint residues. Thus, the trigger of a gun or the handle of a knife could yield biologic evidence of the perpetrator. As background contamination is an issue, this testing is controversial and used by some laboratories for investigatory purposes rather than for use in court as probative evidence. Forensic DNA sequencing has also been applied to the identification of nonhuman samples. Some early studies of mtDNA profiles in domesticated cats and dogs suggested that significant mtDNA control region variation occurred in these species, and that dog and cat hairs found at crime scenes could, therefore, be very probative evidence.8 Subsequent studies have demonstrated that while there is high mtDNA diversity in dogs and cats in the homologous hypervariable control region, it is much more limited than that of humans. Because of this, in most cases mtDNA can be used only as an exclusionary tool in animal casework. However, Savolainen et al.9 have recently shown that certain short tandem repeat regions of the mtDNA molecule in dogs and wolves also possess internal nucleotide variation, virtually individualizing different animals. Although this method cannot be used on hair evidence due to high levels of heteroplasmy, it may be useful for blood and tissue. Cytochrome b, a gene coded for by the mtDNA genome, has been used to identify different species of animals and birds in forensic testing, particularly wildlife investigations.10 Sequencing of a 981 bp amplicon fragment from conserved primer pairs with high homology to many species permits species identification.
FORENSIC mtDNA SEQUENCING The mtDNA particle, a 16.5-kb organellar molecule that codes for 37 different proteins, tRNAs, and rRNAs, is typically present in hundreds to thousands of copies per cell. Interindividual human mtDNA sequence variation is predominantly found in the noncoding region that is made up of two hypervariable regions that flank the origin and is known as the displacement loop (D-loop) or the “control region.” Approximately one third of this 1.1 kb region has been observed to contain nucleotide substitutions relative to a published standard reference sequence, known as the Cambridge Reference Sequence (CRS) or Anderson Sequence.11 This reference sequence has recently been modified (RCRS).12,13
Forensic DNA Sequencing
223
Forensic mtDNA sequencing analysis for identification purposes captures the interindividual sequence variation at approximately 700 bp in the noncoding control region. The bulk of human nucleotide variation exists between nucleotide positions (nps) 15998–16400 (hypervariable region 1, HV1) and nucleotide positions 30 –407 (hypervariable region 2, HV2). The most common strategy is to use the PCR to amplify these two regions from the sample’s extracted DNA template. Evidentiary materials, which are automatically presumed to have minimal and/or degraded DNA, are amplified in four fragments, two for each hypervariable region. Figure 10.1 shows one typical amplification strategy carried out on hair and bone samples. Between 32 and 40 cycles of PCR are used, depending on the template, which typically cannot be quantified pre-PCR as there is no sufficiently sensitive method for detecting the few copies of mtDNA template present in such specimens. Reference blood or buccal swab samples, which have abundant mtDNA, may simply require amplification of HV1 and HV2 alone with as few as 30 or 32 cycles. In fact, the entire control region (nps 15998–407) is often amplified as a single long fragment for databasing highcontent reference mtDNA specimens. More than 40 cycles of PCR and any form of nested PCR are not recommended due to the increased likelihood of amplifying non-authentic products (contaminants) from equipment or reagents. Samples with significant DNA degradation have a template that is broken or cut into short fragments. In these cases, closely spaced PCR primers will successfully amplify the abundant but fragmented mtDNA, which otherwise cannot be captured using the standard approach that generates 250 to 300 base pair amplicons. Overlapping amplicons of 80 to 160 bp in size can be sequenced to provide complete coverage of HV1 and HV2 in what has been called either an “ancient DNA approach”14 or “mini primer set sequencing.”15 This method was pioneered by molecular anthropologists to capture DNA sequence data from fossilized remains like Neanderthal skeletons,16 but can be applied in an identical fashion to any biological material, especially crime scene hairs. Different electrophoretic sequencing instruments are used by forensic laboratories with equal success. In North America, Applied Biosystems 373 and 377 acrylamide gel plate systems are being replaced by its capillary gel electrophoresis 310
Database strategy Hypervariable Region 1
Hypervariable Region 2
Good quality DNA strategy Poor quality DNA strategy
FIGURE 10.1 Typical amplification and sequencing strategy for mtDNA analysis. Two hypervariable regions are targeted in large or small amplicons, depending on the quality of DNA template in the sample and the purpose of sequencing (testing or databasing).
224
Analytical Techniques in DNA Sequencing
(single channel) or 3100 (16 channel) instruments. Other manufacturers of sequencing instrumentation are Beckman and Pharmacia, the latter more commonly used in Europe. Goals of forensic sequence data collection are (1) quality, (2) quantity, and (3) redundancy. Quality of data is first and foremost the most important consideration of a forensic laboratory, and good-quality data permits efficient and confident identification of the nucleotide sequence that characterizes a particular sample. A full profile of 600 to 800 double-stranded base pairs is most desirable; maximum data from the two mtDNA hypervariable regions strengthen the match. Redundancy, or the double-stranded data/overlapping fragment approach, confirms by multiple “looks” the nucleotide substitutions that characterize a particular sample in several independent PCR reactions. Sequencing protocols are optimized during the laboratory’s validation period to reduce the level of noisy background, increase signal strength, and remove chemistry artifacts. Different laboratories have chosen different sequencing chemistries to suit their instrumentation and protocols. Most laboratories are using taq-based cycle-sequencing protocols in kits from various manufacturers. The FBI mtDNA unit uses the Applied Biosystems D-rhodamine chemistry, because while overall it is less sensitive than Applied Biosystems Big Dyes chemistry, it satisfies FBI sensitivity requirements derived from capillary electrophoresis (CE) quantification measurements of first-round PCR products.17 Other laboratories use the Big Dyes chemistry with success. Overall, Sanger’s dideoxyterminator sequencing, rather than dye-labeled primer sequencing, is the method of choice. This is probably true because many different primer sets may be called upon in sample-specific situations to address different control region sequence phenomena. Most laboratories use 25 amplification cycles with predefined input template amounts based either on first-round post-PCR agarose gel quantification (qualitative) or CE quantification (quantitative). Nested cycle sequencing using internal primers is not generally used, as most laboratories use first-round primers for sequencing as well, and rely on internal sequencing primers only for special situations such as length heteroplasmy or degraded template. Most mtDNA control region primer sequences published in the refereed scientific literature may be used for forensic analysis; as a result there are no proprietary issues surrounding primer design and sequence. These primer sequences have been derived largely from early human evolutionary and population genetics studies and are shared throughout the forensic and academic community. Included among published primers are those closely spaced forward and reverse oligonucleotides to use for “ancient DNA” approaches, which cover all of hypervariable region 1 in four to five amplicons and overlap by approximately 10 bp. The AFDIL has developed additional “mini-primer sets” to cover hypervariable region 2.15 While this approach has been very successful in recovering degraded mtDNA template in forensic testing, a commonly encountered limitation is that the DNA extraction material is often exhausted before a complete sequence profile can be developed. This has led to strategies whereby forensic labs choose to consume their finite amount of template in a site-directed approach, confirming observed unique or rare nucleotide substitutions from resequencing multiple PCR reactions, especially in samples with low quantities of DNA, since these sites are most informative and statistically robust in characterizing a sample. Typically, confirmation of
Forensic DNA Sequencing
225
unique or rare sites in multiple PCR reactions gives a high degree of confidence in the authenticity of a profile. One important factor in forensic sequencing not often appreciated elsewhere in the sequencing community is that cycle sequencing product cleanup methods must attempt to preserve as much of the amplicon as possible for sequencing. When miniprimer sets (small amplicons) overlap by only 10 bases, a cleanup method that removes 20 to 40 bases from the 5′ end of the single-strand product or that diminishes the quality of sequence data in this region will be unacceptable. Otherwise there will be no overlap among amplicons. Various methods for product cleanup include generic, inexpensive methods such as ethanol precipitation or kits such as Edge Gel Filtration Cartridges (Edge Biosystems). The regions typically sequenced from the mtDNA molecule have several commonly recognized characteristics that require additional compensatory steps to resolve. When the dual goals of obtaining maximum data and consuming minimal amounts of sample are paired in forensic testing, dealing with sequence artifacts such as site heteroplasmy and length heteroplasmy usually means that a one-size-fits-all protocol will not be useful. Automation is most likely to be successful only where input template quantity can be easily titrated, whereas extraction, amplification, and data analysis may be the most rate-limiting steps, due to individual evidentiary sample needs. Traditional forensic standards require that each DNA sequence be evaluated for quality and edited by two experienced analysts, which takes approximately 30 min per sample per analyst. As a result of this specific challenge, expert sequence analysis software is being developed that will assist the forensic community in shortening DNA sequence analysis time overall by allowing some degree of automated base calling with respect to the RCRS.
FORENSIC mtDNA SEQUENCE INTERPRETATION A basic tenet of forensic analysis is that the defendant should be given the benefit of the doubt to avoid the conviction of an innocent person. Thus, evidence is interpreted with extreme conservatism. Sequences acceptable for other purposes may not necessarily be acceptable for forensic purposes. After mtDNA sequence data are collected, forensic examiners determine if the quality is acceptable for interpretation. There should be limited artifact background (noise). Sequence data should be of uniformly high quality and should lack ambiguity when comparing nucleotide positions on forward and reverse strands and overlapping fragments. Evidence of clear-cut nucleotide differences on different strands when aligning the data with alignment software should result in reanalysis at the bench (if necessary, re-extraction, re-amplification, and/or resequencing). Available software packages such as Sequencher, Sequence Navigator, and Lasergene DNA Star are all satisfactory for analyzing mtDNA data. The most important factor in successful forensic data analysis is the experience of the examiner, who will quickly learn both to recognize mixtures, hypervariable regions 1 and 2 length heteroplasmy, as well as identify hypermutable “hot spots” for site heteroplasmy. Community practice requires all interpretations to be reviewed technically by another experienced examiner, effectively looking at every nucleotide base on the electropherogram traces.
226
Analytical Techniques in DNA Sequencing
Concordance between the examiners is required prior to reporting results, and all base-calling conflicts should be resolved to the satisfaction of both. Documentation is also administratively reviewed. The goal of forensic DNA sequencing in criminal casework is to develop clear inculpatory or exculpatory data from biological samples such as hair, blood, semen, and saliva found at crime scenes and their comparison samples from known individuals who may be connected to the crime. In missing persons cases, which are often linked to criminal investigations, the object of testing is to determine whether human remains are consistent with those of the missing individual by comparison to a family member or a personal effect, such as a toothbrush, containing biological material. The conclusion of the test is that “Person X can be excluded as the contributor of Sample Y” or “Person X cannot be excluded as the contributor of Sample Y,” or in the case of a missing person, “Remains Y can/cannot be excluded as having come from a relative of Person X.” An inconclusive outcome is possible, but fortunately is rare due to the high degree of diversity found in the mtDNA. The forensic scientist works with prosecutors, law enforcement, defense attorneys, and the court to guide their understanding and application of these outcomes. The extent of mtDNA sequence variation is not known and may never be completely known, but in fact, the rare variant mtDNA haplotypes or sequences, estimated to be in the tens of thousands, give forensic mitochondrial DNA testing its primary statistical power. Currently, a novel type observed in casework would not be randomly selected from at least 99.94% of North American individuals. This
TABLE 10.2 Individuals of North American Forensic Significance in the FBI DNA Sequence Database Population African origin
Caucasian Hispanic Asian
Native American
Subpopulation
N
African American Sierra Leone Egyptian Caucasian India
1148 109 75 1655 19 686 163 182 52 329 87 8 146 180
Japan Korea Thailand China/Taiwan Guam Pakistan Navajo Apache
Note: Most sequences cover both hypervariable regions.
Forensic DNA Sequencing
227
estimate is a 95% upper bound frequency based on the size of a forensic database maintained by the FBI (N = 4839; Table 10.2).4 Therefore, for the foreseeable future, mtDNA sequencing is the method of choice to assay the rare, valuable variation present in this small genome. Mitochondrial DNA haplotypes vary in frequency; all ethnic populations show a distribution with a few high-frequency haplotypes and a majority of rare haplotypes (Figure 10.2). Within the pool of Caucasian mtDNAs found in Europe and North America, there is a single type that occurs at “high” frequency, found in approximately 7% of these individuals. This type is characterized by a nucleotide substitution with respect to the CRS at position 263 (A to G in the light strand orientation) and one or more light strand C insertions at positions 309 and 315 in the hypervariable region 2 homopolymeric C-stretch. When a high-frequency haplotype is observed in casework and results in a match between questioned and known samples, some degree of uncertainty regarding the true source of the sample will naturally exist. Two additional regions 3′ to the two hypervariable regions that contain somewhat limited control region nucleotide variation, called Variable Region 1 (nps 16471–16562) and Variable Region 2 (nps 424–548), can further test the presumed match by identifying nucleotide differences between the two samples, obviating the match. Research is under way to investigate nucleotide positions within other portions of the mtDNA genome, especially coding regions, that will aid in discriminating subtypes of this and other somewhat common types recognized in current databases. Ultimately some form of SNP assay may be used to add limited sequence data for additional match-testing. It is well recognized that ethnic classification is correlated with mtDNA haplotype clusters, or “haplogroups” (but by no means is always predictive of phenotype).18,19 This ethnicity correlation is helpful in identifying common profiles that need further investigational studies to discriminate them.
FIGURE 10.2 Distribution of haplotype frequencies in a European-American database.
228
Analytical Techniques in DNA Sequencing
MITOCHONDRIAL DNA HETEROPLASMY The baseline state of an organism’s tissue is mitochondrial homoplasmy, wherein each mitochondrial DNA molecule has an identical sequence over the entire length. In reality, however, probably each individual is heteroplasmic to some degree, meaning that two or more populations of different mtDNA molecules, one the “wild-type” dominant population and the other(s) minor, inhabit the mitochondria. The minority mtDNA populations start as single copies that have sustained mutational changes at single nucleotide positions. Some may rise to detectable frequency in certain tissues through mtDNA replication, while the vast majority will not. This heteroplasmic state is well recognized in mitochondrial genetic disease, where the dosage of mutated or nonwild-type molecules deleteriously affecting coding regions may be correlated with the severity of the syndrome. In forensic testing, mtDNA site heteroplasmy is observed at frequencies ranging from approximately 1% of blood samples to 15% of hairs,5,20 and usually appears as two nucleotide peaks (C plus T, or A plus G, and more rarely as purine-pyrimidine combinations) at a single position in the sequenced region (Figure 10.3). The existence of two or more heteroplasmic sites in a single forensic sample has been reported, but appears to be rare.21 In casework, a heteroplasmic position should be confirmed by sequencing both the light and heavy strands of DNA to observe it in both orientations, and may also be confirmed by sequencing multiple or overlapping amplicons. Site heteroplasmy is most commonly observed at so-called “fast sites,”
TGTATTTCGTA
TGTATTTCGTA Nucleotide position 16093
FIGURE 10.3 Example of mtDNA site heteroplasmy showing the C/T mixture on the light and heavy strands (both orientations; the heavy strand has been reverse-complemented). This is position 16093 in HV1, one of the most common “hot spots,” where T is the RCRS nucleotide and this individual has T/C.
Forensic DNA Sequencing
229
which have been observed in phylogenetic studies to have mutated multiple times in human history. Heteroplasmy appears to vary among tissues. Higher levels of site heteroplasmy in hairs is explained by a small bottleneck during individual, monoclonal hair development that allows mutational changes to arise to detectable levels from a small number of starting copies of mtDNA. In contrast, blood originates from a polyclonal source (bone marrow) and is mixed throughout the body, making detectable site heteroplasmies less likely to be sampled. The overwhelming majority of mtDNA molecules in an individual are identical. Length heteroplasmy is a very commonly observed phenomenon in mtDNA control region sequencing in two regions, the area surrounding a small homopolymeric cytosine (C) stretch in hypervariable region 1 where a T-to-C transition at position 16189 sometimes occurs, and in a longer C stretch around position 309 in hypervariable region 2.22 In casework these areas exhibit some degree of length heteroplasmy, from mild and almost undetectable to severe and uninterpretable, in around 30% of samples. The presumed mechanism for this phenomenon is that the polymerase involved in mtDNA replication cannot faithfully reproduce the correct ancestral number of C molecules, which results in populations of molecules in the individual with 7 Cs, 8 Cs, 9 Cs, etc. (Figure 10.4). First-round PCR amplification determines which proportions of these templates will appear in the sequence data, and repeated amplifications of these templates show remarkable fidelity in replicating the approximate ratios of the populations of varying lengths. Therefore, it is believed that sequence data represent well the approximate proportions of different length templates. In sequencing these templates containing different populations with varying numbers of cytosines, the sequence often cannot be read 3′ to the C stretch due to the overlapping template molecules. To correct this problem, the PCR template should be sequenced with internal primers downstream of the C stretch, and also sequenced in both directions on both light and heavy strands. This will allow evaluation of the sequence 3′ to these complex regions.
MIXTURES When a mixture is present for mtDNA, it is currently impossible to sort out the linkage phase of the mixed haplotypes without cloning and then sequencing the clones, a prohibitively expensive proposition. Mixed haplotypes are not necessarily additive—when a major discrepancy in proportion of the mixture components exists (at least 80:20), nucleotide base “dropout” of the minor component is often observed. Alternatively, if the mixture components are approximately equal, then nucleotide peaks at the variant positions may shift back and forth in height in different PCR products, making it impossible to assign linkage phase. Multiple haplotypes may be generated by the large numbers of permutations of the mixed sites, for example, a sequence displaying 5 mixed sites results in 32 possible mtDNA haplotypes (52 = 32). In addition, different primer pairs have variable performance under the same conditions, complicating the comparison of overlapping regions.
230
Analytical Techniques in DNA Sequencing
(a)
C
C
A
C
C
A
A
A
C
C
C
C
C
C
C
T
C
C
C
C
C
C
G
C
T
T
C
T
G
( b)
C A C C A A A C C C C C C C C T C C C C C C G C T T c T G
(c)
C C A C C A A A C C C C C C C C N T C C C C C C G c T T c T G
FIGURE 10.4 Mitochondrial DNA HV2 homopolymeric C stretch: (a) no length heteroplasmy, (b) length heteroplasmy showing less severe effect on sites downstream (3′ end, light strand) of the length variants, with a single C insertion after position 309 relative to the RCRS being dominant (309.1); (c) length heteroplasmy showing more severe effect on sites downstream (3′, light strand) of the length variants, with two C insertions after position 309 relative to the CRS dominant (309.1, 309.2). Position 309 is denoted by the arrow.
REFERENCES 1. Wilson M, DiZinno JA, Polanskey D, Replogle J, Budowle B. Validation of mitochondrial DNA sequencing for forensic casework analysis. Int J Legal Med 108:68–74, 1995. 2. Carracedo A, D’Aloja E, Dupuy B, Jangblad A, Karjalainen M, Lambert C et al. Reproducibility of mtDNA analysis between laboratories: a report of the European DNA profiling group (EDNAP). Forensic Sci Int 97:165–170, 1998. 3. Carracedo A, Bär W, Lincoln P, Mayr W, Morling N, Olaisen B et al. DNA Commission of the International Society for Forensic Genetics: guidelines for mitochondrial DNA typing. Forensic Sci Int 110:79–85, 2000. 4. Holland MM, Parsons TJ. (1999) Mitochondrial DNA sequence analysis: validation and use for forensic casework. Forensic Sci Rev 11(1):21–50, 1999.
Forensic DNA Sequencing
231
5. Melton T, Nelson K. Forensic mitochondrial DNA analysis: two years of commercial casework experience in the United States. Croatian Med J 42(3):298–303, 2001. 6. Morley JM, Bark JE, Evans CE, Perry JG, Hewitt CA, Tully G. Validation of mitochondrial DNA minisequencing for forensic casework. Int J Legal Med 112:241–248, 1999. 7. Andreasson H, Asp A, Alderborn A, Gyllensten A, Allen M. Mitochondrial sequence analysis for forensic identification using pyrosequencing technology. BioTechniques 31(2):2–9, 2001. 8. Savolainen P, Lundeberg J. Forensic evidence based on mtDNA from dog and wolf hairs. J Forensic Sci 44(1):77–81, 1998. 9. Savolainen P, Arvestad L, Lundeberg J. A novel method for forensic investigation: repeat-type sequence analysis of tandemly repeated mtDNA in domestic dogs. J Forensic Sci 45(5):990–999, 2000. 10. Zehner R, Zimmerman S, Mebs D. RFLP and sequence analysis of the cytochrome b gene of selected animals and man: methodology and forensic application. Int J Legal Med 111:323–327, 1998. 11. Anderson S, Bankier AT, Barrell GB, de Bruijn MHL, Coulson AR, Drouin J, Eperon IC, Nierlich DP, Roe BA, Sanger F, Schreier PH, Smith AJ, Staden R, Young IG. Sequence and organization of the human mitochondrial genome. Nature 290:457–465, 1981. 12. Andrews RM, Kubacka I, Chinnery PF, Lightowlers RN, Turnbull DM, Howell N. Reanalysis and revision of the Cambridge reference for human mitochondrial DNA [letter]. Nat Genet 23(2):147, 1999. 13. Wallace DC, Lott MT. MITOMAP: A human mitochondrial genome database, http://www.mitomap.org, 2003. [Revised Cambridge Reference Sequence: http://www. mitomap.org/mitomap/mitoseq.html] 14. Pääbo S, Higuchi RG, Wilson AC. Ancient DNA and the polymerase chain reaction: the emerging field of molecular archaeology. J Biol Chem 264:9709–9712, 1989. 15. Gabriel MN, Huffine EF, Ryan JH, Holland MM, Parsons TJ. Improved mtDNA sequence analysis of forensic remains using a “mini-primer set” amplification strategy. J Forensic Sci 46(2):247–253, 2001. 16. Krings M, Stone M, Schmitz RW, Krainitzke H, Stoneking M, Pääbo S. Neanderthal DNA sequences and the origin of modern humans. Cell 90:19–30, 1997. 17. Isenberg AR, Moore JM. Mitochondrial DNA analysis at the FBI Laboratory. Forensic Science Communications 1(2), 1999, http://www.fbi.gov/fbilibrary/forensicsciencecommunications/backissues. 18. Connor A, Stoneking M. Assessing ethnicity from human mitochondrial DNA types determined by hybridization with sequence-specific oligonucleotides. J Forensic Sci 39:1360–1371, 1994. 19. Melton T, Clifford S, Kayser M, Nasidze I, Batzer M, Stoneking M. Diversity and heterogeneity in mitochondrial DNA of North American populations. J Forensic Sci 46:46–52, 2001. 20. Calloway CD, Reynolds RL, Herrin GL, Anderson WW. The frequency of heteroplasmy in the HVII region of mtDNA differs across tissue types and increases with age. Am J Hum Genet 66:1384–1397, 2000. 21. Budowle B, Allard MW, Wilson MR. Critique of interpretation of high levels of heteroplasmy in the human mitochondrial DNA hypervariable region I from hair. Forensic Sci Int 126:30–33, 2002. 22. Stewart JEB, Fisher CL, Aagaard TJ, Wilson MR, Isenberg AR, Polanskey D et al. Length variation in HV2 of the human mitochondrial DNA control region. J Forensic Sci 46(4):862–870, 2001.
Index (‘i’ indicates an illustration; ‘t’ indicates a table) 5-Carboxyrhodamine-110, 17, 18i 5-Carboxyrhodamine-6G, 16, 16i
A Ab initio gene prediction, 171, 172, 173 ABI 3730 (Applied Biosystems), 160 ABI PRISM 3700 analyzer, 35, 41 Agriculture, origins and spread, 211–212 Amber, as ancient DNA source, 201–202 Ambient temperature, and single-molecule sequencing, 108, 110 Amplification (integrated), 74–75 AmpliTaq FS (ABI), 38, 41 Ancient DNA analysis agriculture, 211–212 amplification, 203–204 authentification, 204–205 damage, 196, 197 and evolution, 206–211 extinct animals, 211 extraction, 202–203 future studies, 212 history, 195–196 limitations, 201 preservation assessment, 199–200 target loci, 205–206 Anderson Sequence, 222 Aqueous piperide sequencing method, 5 Arbidopsis, genome, 159, 172 Armed Forces DNA Identification Laboratory (AFDIL), 219
B Background fluorescence, 138 Bacteria; artificial chromosomes (BACs), 31, 74, 159, 162 Bacterial colony sequencing, 37–40 Bacteriophage M13, 163, 166 Base stacking, 32–33, 52 Base-specific cleavage, MALDI-TOF-MS, 92–93 Berkeley rotary scanning confocal microscope, 67, 70i BigDye™ set, 19–20, 21t BLAST, sequence similarity, 172
Blood samples, 33, 53, 54 BODIPY dyes, 18, 19i lifetimes, 24 Bone, as ancient DNA source, 201 Buccal swabbing, 33, 53
C Cambridge Reference Sequence (CRS), 222 Capillary array electrophoresis (CAE), 31, 35–37, 61, 65–71 Capillary electrophoresis sequencing, (CE), 2, 7–9, 61–62 lifetimes, 23 Capillary gel electrophoresis (CGE), 31–32, 138 Capillary microfluidics systems, 34 Centrifugation, 31, 55 CEQ 2000 DNA analysis system (Beckman Coulter), 36 Cheek cell samples, 33, 54–55 Chemical assessment, ancient DNA, 200 Chip, definition, 178 “Chip scanner,” 67, 70i Clemson University Genomics Institute, 161, 163 Clinical samples, UV detection, 53, 54 Cloning vectors, shotgun sequencing, 163 Colony sequencing, 37 Combinatorial performance, SBH, 180, 189, 190 Complementary hybridization, 178 Consed, contig editor, 165–166 Consensus sequence, 165–166, 168 Contigs, 164 Coprolites, as ancient DNA source, 202 Cot analysis, 171 Cross-injector, 62–63, 63i Cyanine dye (CYA), 16, 17i, Cycle-sequencing, nanoreactor, 41–47, 42i, 44i, 46i Cystic fibrosis, and MALDI TOF-MS, 97 CZE purification, 47, 50 CZE-CGE system, 47–52
D De novo sequencing, 90, 102, 178, 191 Degradation, natural DNA, 196–197, 197i
233
234
Index
Detection, 9–10, 99 Detection, single molecule, 110–113 Diagenic changes, ancient DNA, 200, 202 Dichronic beam splitter, 120 DNA library, 163 DNA markers, 96 DNA polymerases, 6 DNA sequencing publications, 10 Donor-acceptor dyes, 19 Dot/blots, forensic DNA testing, 218 Drosophila, genome, 159, 170 Dyes bacterial colony sequencing, 38 properties, 14 and single-molecule sequencing, 109–110 suitability for single-molecule sequencing, 112
E Electrophoresis, 6–7. See also Capillary electrophoresis (CE) Electrospray ionization (ESI), 85, 89 Emission-based detection, 20 End sequencing, BACs, 161, 162 Energy transfer-based florescence, 14–18 Energy transfer (ET) primers, 14–18, 62 comparison, 17 Environment, in DNA degradation, 199–200 Escherichia coli, 37, 39 Eukaryotic genome sequencing, 169–171 Eulerian path, 179, 180i Evidentiary specimens, forensic DNA testing, 219 Exonuleases, 108, 125, 146 Expressed sequence tag (EST) sequencing, 158 Extinct animal studies, 211
F FAM donor dye, 14, 15t, 16 FASTA, sequence similarity, 172 Feature, definition, 178 FgenesH, gene prediction, 172 Finishing, genome sequencing, 164 Fluorescein, 19 lifetimes, 24 Fluorescence-based single-molecule sequencing, 108 Fluorescence detection, 9–10, 13–14, 110–111 lifetimes, 21, 114, 117–118 Fluorescent nucleotide monophosphate molecules (dNMPs), 38, 45, 109 Forensic DNA testing, 217 contamination, 221 history, 218–219 specimen documentation, 219–220 standards, 220
Forensic mitochondrial DNA (mtDNA) analysis, 217–218 applications, 221–222 heteroplasmy, 228–229 interpretation, 225–227 mixtures, 229–230 sequencing, 222–225 Formamid low temperature (FoLT) PCR, 33 Fossil samples, degradation, 197 Four-color detection, 26 Fourier-transform ion-cyclotron-resonance (FT-ICR) analyzers, 89–90 FPC Contig Assembly, 160, 161, 162
G Gap closure, 164, 168 Gaps, genome sequencing, 166, 168 GeneMapper (Applied Biosystems), 161 GeneScan fragment sizing, 160 gene prediction, 172 Genetic marker analysis, 96 Genome, definition, 157 Genome sequence annotation, 157 GenoProfiler, 161 Glimmer, gene prediction, 171–172 GOOD assay, 99 Guatemala “disappeared,” and forensic DNA testing, 219
H H. influenzae, genome, 167, 168 Hamiltonian path, 179, 180i Haplotype frequencies, forensic DNA testing, 227, 227i Heteroplasmy, mitochondrial DNA, 228–229 High-density labeling, 121– High-Information Content Fingerprinting (HICF), 160, 161 Human evolution, use of ancient DNA analysis, 206–211 Human Genome Project, 1, 29, 61, 107 gaps, 169 Hybridization assays, forensic DNA testing, 218 Hydrodynamic focusing sample stream, 128–134 Hyper-turn design, 67, 68i
I Identify testing, forensics, 217 Incorporation, labeled nucleotidase, 121–125 Inorganic phosphate sequencing method, 6 Integrated bioprocessors, sample amplification, 74–75
Index
235
Integrated bioprocessors, sample purification, 75–80
J JOE acceptor dye, 14, 15t, 16 Jumping PCR, DNA degradation, 197, 198i, 199
K Klenow fragment, 6, 124
L Large scale comparative sequence analysis, 95 Laser-induced fluorescence (LIF) detection, 52 and single-molecule sequencing, 111–113, 112i Library, definition, 178 Lin-TOF analyzers, 89 Linear polyacrylamide (LPA), 64 coated capillaries, 36 “Low copy number” (LCN) DNA testing, 222
M Mapped genome sequencing, 169–170 Mass spectrometry (MS), 85. See also Matrixassisted laser desorption/ionization (MALDI) integrated SNP analysis, 99, 108 Matrix-assisted laser desorption/ionization (MALDI), 85, 108 allele frequency determination, 101 base-specific cleavage, 92–93, 93i disease identification, 97 future developments, 101–102 ion fragmentation, 88–89 large scale comparative sequence analysis, 95 mass analyzers, 89–90 PCR transcription-based, 94 polymorphism analysis, 97–100 quantification, 90 sample preparation, 87–88 sample purification, 86–87 sequencing ladder analysis, 91 SNP scoring, 97 Maxam-Gilbert sequencing method, 2–3 compared to Sanger, 3–4 Maximum likelihood estimator (MLE) algorithm, 118, 119 MegaBACE 1000 (Molecular Dynamics), 8, 35 Methanol, 138 Microarray technology, 179i
Microchannels, single-molecule sequencing, 134–146 Microchips, 34–35 CAE, 36–37, 65 Microfabricated CAE (mCAE) bioprocessor applications, 71–74 high-throughput, 67, 69i, 69, 71i prototypes, 65–67, 66i Miniaturization, 40, 64 Mitochondrial DNA (mtDNA), 56 ancient, 205 forensic, 217–218 forensic applications, 221–222 forensic interpretation, 225–227 forensic sequencing, 222–225 heteroplasmy, 228–229 mixtures, 229–230 Mixed haplotypes, mitochondrial DNA, 229 Mobility shift, ET primers, 15 Model DNAs, 125–126 Molar absorptivity, 20 Molecular Evolution Laboratory, UC Berkeley, 218 Molecular Probes, 19 Multiexponential decay, 21 Multiplexing, 40 Mutant polymerases, 124, 125
N Nano-total analysis, 34–35 Nanoliquid handling, 99 Nanoreactor, cycle-sequencing, 41–47, 42i, 44i, 46i Natural sequences, memoryless source model, 183, 192 Nd:YAG laser, 113, 116 Neanderthal specimens admixture with modern humans, 210–211 ancient DNA analysis, 206–209 divergence, 209. 210i diversity, 210 Nuclear vs. mitochondrial DNA, uses, 221–222 Nucleic acids, MS analysis, 85, 101. See also Matrix-assisted laser desorption/ionization (MALDI) Nucleotide transport velocity, 129
O One photon excitation (OPE), 115 Online microchip systems, 34–35 Online microfluidics systems, 33 Online sample purification, 47–52
236
Index
P Phase domain, fluorescence lifetime, 21, 23i, 23–25 Photobleaching, 113, 115, 116, 136 Photoresist (PR) resin, 62 Photostable fluorescent dyes, 110 PHRAP assembler, 164 PHRED automated sequencer, 162, 164 Physical mapping applications, 160, 160i, 161 Planar CE chip technology, 62 Plasmid Bluescript, 37, Plasmid clones, 163, 166 Plasmid preparation, 31 PMMA (polymethylmethacrylate)-based microchips, 35 Polyacrylamide gel electrophoresis (PAGE), 2, 3 size-based separation, 6–7 Polymerase chain reaction (PCR), 5, 30 and ancient DNA analysis, 196, 203–204 BAC libraries, 162 bacterial colony sequencing, 38 clinical samples, 52–56 fluorescence incorporation, 122 in forensic DNA analysis, 223, 224 gap closure, 168 integrated amplification, 74 sample preparation, 33 transcription for MALDI-TOF-MS, 94 and UV-MALDI analysis, 87 Polymethylmethacrylate (PMMA) microchannels, 135, 136 Polymorphisms, MALDI TOF-MS, 96–97 Primer oligo base extension (PROBE) assay, 97 Production sequencing, 163–164 Purification (integrated), 75–80
Q Quantum yield, 14, 20
R “Racetrack effect,” 66 Radioactive labeling, 9, 13 Radioisotope sequencing, 1 Read-out, definition, 178 Resequencing, MALDI TOF-MS, 92 Restriction fragment length polymorphisms (RFLPs), 96, 217 Revised Cambridge Reference Sequence (RCRS), 222, 225 Rhodamine dyes, 19, 38, 113, 125 and oxazine, 138 Robotics, 33
Rough draft WGS, 171 ROX acceptor dye, 14, 17
S Sample collection, 33 Sample purification, 32 ESI-MS, 87 integrated, 77–80 UV-MALDI, 86–87 Sanger, Fred, 3 Sanger sequencing method, 3 compared to Maxam-Gilbert, 3–4 MALDI-TOF-MS alternative, 91 Separation, 6–8, 64, 99 Sequence tagged connectors (STCs), 162 Sequence tagged sites (STSs), 162 Sequence-ready genomic frameworks, 159–163 Sequencing by hybridization (SBH), 178 biochemistry, 190–191 optimality, 191–192 performance optimization, 187–189 probing scheme, 181–183 reconstruction, 183–187 Sequencing ladder analysis, MALDI-TOF-MS, 91 Short tandem repeats (STRs), 96, 217 Shotgun sequencing, 163, 166 Simple sequence repeats (SSRs), 163 Single nucleotide polymorphisms (SNPs), 96–97 multiplexing, 100, 100i, 102 primer-extension-based analysis, 97, 98i Single-channel, sequencing, 64–65 Single-molecule sequencing, 108 detection, 110–113 future strategies, 146–147 hydrodynamic focusing sample stream, 128–134 identification, 113–121 incorporation and degradation, 121–128 microchannels, 134–146 procedure, 108–109, 109i submicrometer capillaries, 134–146 Size-exclusion columns (SEC), 38, 45, 47, 54 Slab-gel sequencing, 6–7 compared to CGE, 32 lifetimes, 22 Small-volume solutions, 41 Soft tissue, as ancient DNA source, 201 Solvent evaporation, 35 SpectruMedix analysis system, 36 Submicrometer capillaries, single-molecule sequencing, 134–146
Index
237
T TAMRA acceptor dye, 14, 15t, 16 Target, definition, 178 Temperature lowering, 108 The PinPoint™ assay, 99 Thermo aquaticus (Taq) polymerase, 6, 199 ThermoSequenase (Amersham Life Science), 38, 41 Ti:sapphire laser, 116 TIGR (Institute for Genomic Research) Assembler, 164 TIGR (Institute for Genomic Research), H. influenzae genome, 167, 168 Time domain, fluorescence lifetime, 21–22, 22i Time-correlated single photon counting (TCSPC), 116–121 Time-resolved identification, 140–141, 144 Tunneling microscopy, 108 Two-photon excitation (TPE), 115, 116
U UV detection, clinical samples, 53, 54
V Very large scale integration (VLSI) processing, 62, 65
W Watson/Crick-complementary binding, 178, 190 Whole genome sequencing, 163–172 Whole-Genome Shotgun (WGS), 167, 170
Y Yeast artificial chromosome (YAC), 159